HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJG 1126-2016 English PDF

US$739.00 ยท In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJG 1126-2016: High Voltage Dielectric Loss Tester
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 1126-2016English739 Add to Cart 5 days [Need to translate] High Voltage Dielectric Loss Tester Valid JJG 1126-2016

PDF similar to JJG 1126-2016


Standard similar to JJG 1126-2016

JJF 1234   JJG 376   JJF 1126   JJF 2000   JJG 1129   JJG 1120   

Basic data

Standard ID JJG 1126-2016 (JJG1126-2016)
Description (Translated English) High Voltage Dielectric Loss Tester
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A55
Word Count Estimation 32,322
Date of Issue 2016-06-27
Date of Implementation 2016-09-27
Regulation (derived from) State Administration of Quality Supervision, No.66 of 2016
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine

JJG 1126-2016: High Voltage Dielectric Loss Tester

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
High Voltage Dielectric Loss Tester National Metrological Verification Regulation of the People's Republic of China High pressure dielectric loss factor tester 2016-06-27 released 2016-09-27 implementation State Administration of Quality Supervision, Inspection and Quarantine issued High pressure dielectric loss factor Test instrument verification procedures Unit. National Electromagnetic Metrology Technical Committee High Pressure Metering Subcommittee Major drafting unit. National high voltage metering station State Grid Shaanxi Electric Power Company Electric Power Research Institute Participated in the drafting unit. State Grid Anhui Electric Power Company Electric Power Research Institute State Grid Gansu Electric Power Company Shanghai think of a new electrical Equipment Co., Ltd This procedure is entrusted to the National Electromagnetic Metrology Technical Committee of the High Pressure Metrology Subcommittee. The main drafters of this procedure. Lei Min (National High Voltage Metering Station) Wang Siqi (National High Voltage Metering Station) Huang Guoqiang (State Grid Shaanxi Electric Power Company Electric Power Research Institute) Participate in the drafters. Zhang jun (national high voltage metering station) Zhu Qi (State Grid Anhui Electric Power Company Electric Power Research Institute) Yang Xianming (State Grid Gansu Electric Power Company) Zhu Bin (Shanghai think of a electrical equipment Limited)

table of Contents

Introduction (II) 1 Scope (1) 2 References (1) 3 Overview (1) 4 Measurement performance requirements (2) 4.1 Accuracy class (2) 4.2 Maximum permissible error (2) 4.3 Demonstration resolution (2) 4.4 Measurement Repeatability (2) 5 General technical requirements (2) 5.1 appearance and markings (2) 5.2 Dielectric strength (2) 5.3 Other requirements (3) 6 Metering device control (3) 6.1 Test conditions (3) 6.2 Test items and verification methods (3) 6.3 Processing of Verification Results (7) 6.4 Test cycle (8) Appendix A Verification of the original record format (9) Appendix B Verification Certificate/Verification Result Notification Page Format (16) Appendix C Certificate of Verification/Verification Result Verification Result Page Format (17)

Introduction

This procedure is based on JJF1002-2010 "national measurement procedures for the preparation of rules" prepared. This procedure is for the first time. Verification Regulation of High Pressure Dielectric Loss Factor Tester

1 Scope

This procedure is applicable to digital (numerically) high capacity for measuring capacitance and dielectric loss factor under power frequency power conditions Pressure dielectric loss tester (hereinafter referred to as the loss of the instrument) of the first test, follow-up test and use of the inspection. This procedure does not apply to Xilin type, current comparison instrument type bridge.

2 reference file

This procedure refers to the following documents. JJG 563-2004 "high voltage capacitance bridge" JJG 1075-2012 "high voltage standard capacitor" For dated references, only the dated edition applies to this rule; references that are not dated , The latest version (including all amendments) applies to this procedure.

3 Overview

Dielectric loss measurement capacitor capacitance and dielectric loss factor when the working wiring shown in Figure 1, the dotted line Dielectric loss instrument. Dielectric loss instrument is a kind of integrated design in the structure, the application of digital measurement technology for a variety of high-voltage power Equipment and equipment for automatic measurement of capacitance and dielectric loss factor. Usually by the measuring unit, built-in high pressure test Power and high voltage standard capacitors consisting of measuring devices. The maximum output voltage of the high voltage test power is usually 10kV, the output test voltage frequency is 45Hz ~ 55Hz. Figure 1 working instrument wiring diagram Cx-measured capacitance type equipment; Cn-dielectric loss instrument built-in high voltage standard capacitor

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 1126-2016_English be delivered?

Answer: Upon your order, we will start to translate JJG 1126-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 1126-2016_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 1126-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.