Verification Regulation of Ammonia Gas Detectors
| Valid |
JJG 1105-2015
|
PDF similar to JJG 1105-2015
Basic data Standard ID | JJG 1105-2015 (JJG1105-2015) | Description (Translated English) | Verification Regulation of Ammonia Gas Detectors | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A61 | Classification of International Standard | 17.020 | Word Count Estimation | 15,132 | Date of Issue | 2015-01-30 | Date of Implementation | 2015-04-30 | Regulation (derived from) | The State Administration of Quality Supervision, Inspection and Quarantine Announcement 2015 No. 19 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This Standard applies to measuring air or nitrogen gas analyzers for initial verification and detection alarm ammonia content of the subsequent verification and the use of checks. |
JJG 1105-2015: Verification Regulation of Ammonia Gas Detectors---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Ammonia Gas Detectors
State verification procedures People's Republic of China
Ammonia detector
Issued on. 2015-01-30
2015-04-30 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Ammonia detector test procedures
Detectors
Focal point. the National Technical Committee on Environment stoichiometry
The main drafting units. China Institute of Metrology
Jinan City, the metrological verification
Jinan Changqing Computer Application Companies
Participated in the drafting unit. Jiangsu Province Institute of Metrology
This procedure commissioned the National Technical Committee of the stoichiometric environment responsible for interpreting
The main drafters of this procedure.
Liu Yi Ling (China Institute of Metrology)
Chen Yonghua (China Institute of Metrology)
Wang Limin (Jinan City, the metrological verification)
Qin Yanchang (Changqing Computer Application Companies)
Drafters participate.
Wang Defa (China Institute of Metrology)
Yuezong Long (Changqing Computer Application Companies)
Cai Ye Qiang (Jiangsu Province Institute of Metrology)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2 Overview (1)
3 metering performance requirements (1)
3.1 indication error (1)
3.2 Repeatability (1)
3.3 Response Time (1)
3.4 Stability (1)
4 General Requirements (1)
4.1 Appearance and structure (1)
4.2 marks, and logos (2)
4.3 energizing check (2)
4.4 Insulation Resistance (2)
4.5 dielectric strength (2)
4.6 Alarm function (2)
5 control of measuring instruments (2)
5.1 Environmental test conditions (2)
5.2 Calibration with standard materials and equipment (2)
5.3 Verification Project (3)
5.4 Verification Methods (4)
5.5 Verification Results Processing (5)
5.6 test cycle (5)
Appendix A test recording format (6)
Appendix B test certificates/test results in the notice page format (7)
Introduction
This procedure is based on JJF1002-2010 "national verification procedures write rules", JJF1001 "general purpose
Volume terms and definitions "and JJF1059.1" Evaluation and Expression of Uncertainty in Measurement "basis and developed.
This procedure was first formulated.
Ammonia detector test procedures
1 Scope
The order applies to the measurement of ammonia content in the air or nitrogen gas analyzer and detector alarm (hereinafter referred to as analysis
Instrument and alarm, collectively referred to as the instrument) initial verification, subsequent verification and the use of checks.
2 Overview
Instrument detection principle electrochemical, infrared sound and light, non-dispersive infrared chemiluminescence, UV and the like. Sampling Method
There are two kinds of inhaled and diffusion, use is divided into fixed and portable. General Instrument by the sensor chamber, the sampling
Components, electronic circuits, monitors and other components.
3 metering performance requirements
3.1 Indication error
Indication error to meet the requirements of Table 1.
Specified in Table 1 the maximum permissible error
Measuring range/(μmol/mol) analyzer alarm
0≤C≤50 ± 10% ± 10%
50 \u003cC≤1000 ±6% ±10%
3.2 Repeatability
Analyzer, the alarm repeatability relative standard deviation of not more than 2% and 3%.
3.3 Response Time
Inhaled Sampling Method instrument response time of less than 120s; diffusion Sampling Method instrument response time
Room is not greater than 180s.
3.4 Stability
3.4.1 Zero Drift
Analyzer, the alarm zero drift does not exceed ± 1% FS, ± 2% FS.
3.4.2 Span drift
Analyzers, alarm span drift does not exceed respectively ± 2% FS, ± 3% FS.
4 General technical requirements
4.1 Appearance and structure
4.1.1 The instrument shall not affect the appearance of their normal work injury. Surface of the new instrument should be made smooth, paint
Color uniform coating, no rust flaking phenomenon.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 1105-2015_English be delivered?Answer: Upon your order, we will start to translate JJG 1105-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 1105-2015_English with my colleagues?Answer: Yes. The purchased PDF of JJG 1105-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|