US$369.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 1102-2014: Verification Regulation of Installed Personnel α, β Surface Contamination Monitoring Assemblies Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
JJG 1102-2014 | English | 369 |
Add to Cart
|
3 days [Need to translate]
|
Verification Regulation of Installed Personnel α, β Surface Contamination Monitoring Assemblies
| Valid |
JJG 1102-2014
|
PDF similar to JJG 1102-2014
Basic data Standard ID | JJG 1102-2014 (JJG1102-2014) | Description (Translated English) | Verification Regulation of Installed Personnel ��, �� Surface Contamination Monitoring Assemblies | Sector / Industry | Metrology & Measurement Industry Standard | Classification of Chinese Standard | A58 | Classification of International Standard | 17.240 | Word Count Estimation | 16,183 | Date of Issue | 8/25/2014 | Date of Implementation | 11/25/2014 | Quoted Standard | JJG 478-1996; JJF 1001-2011; GB/T 4960.1-2010; GB/T 4960.6-2008; GB/T 5202-2008; GB/T 8997-2008; IEC 61098-2003 | Regulation (derived from) | People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine Notice 2014 (No. 95); AQSIQ Notice 2014 No. 95 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine | Summary | This Standard applies to fixed ��, �� surface contamination personal monitoring device initial verification, use and subsequent verification check. This Standard does not apply to portable ��, �� surface contamination meters and monitors, as well as �� particl |
JJG 1102-2014: Verification Regulation of Installed Personnel α, β Surface Contamination Monitoring Assemblies ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Installed Personnel α, β Surface Contamination Monitoring Assemblies
State verification procedures People's Republic of China
Fixed α, β surface contamination personal monitoring device
InstaledPersonnelα, βSurfaceContaminationMonitoringAssemblies
Issued on. 2014-08-25
2014-11-25 implementation
The State Administration of Quality Supervision, Inspection and Quarantine released
Fixed α, β personal surface contamination
Test procedures monitoring device
Personnelα, βSurfaceContamination
Focal point. the National Technical Committee of ionizing radiation metrology
Main drafting unit. Shanghai Institute of Measurement and Testing
Participated in the drafting. Shenzhen Academy of Metrology and Quality Inspection
This procedure commissioned the National Technical Committee is responsible for ionizing radiation measurement interpretation
The main drafters of this procedure.
Tangfang Dong (Shanghai Institute of Measurement and Testing)
He Linfeng (Shanghai Institute of Measurement and Testing)
Drafters participate.
Zhou Yingchun (Shenzhen Academy of Metrology and Quality Inspection)
Xu Yihe (Shanghai Institute of Measurement and Testing)
table of Contents
Introduction (Ⅱ)
1 Scope (1)
2. References (1)
3 terminology and units of measurement (1)
3.1 The term (1)
3.2 units of measurement (1)
4 Overview (2)
5 metering performance requirements (2)
5.1 systemic α, β surface contamination monitoring device (2)
5.2 hands α, β surface contamination monitors (2)
6 General Requirements (3)
6.1 Appearance (3)
6.2 identification (3)
7 control of measuring instruments (3)
7.1 test conditions (3)
7.2 Verification Project (3)
7.3 Verification Methods (4)
7.4 Verification Results Processing (5)
7.5 test cycle (6)
Appendix A fixed α, β surface contamination monitoring device for personal verification original record format (7)
Appendix B test certificate within the page and format (9)
Appendix C test results in the notice page and format (10)
Introduction
Fixed α, β surface contamination monitoring device for personal radiation protection instruments belonging to online use for open discharge
Radioactive workplace and staff of nuclear facilities the hot zone of radioactive surface contamination monitoring its performance directly affects the measurement monitoring
Accurate and reliable results, relating to radiation safety.
JJF1002-2010 "national verification procedures write rules", JJF1001-2011 "common terminology and measurement
Definitions ", JJF1059.1-2012" Evaluation and Expression of Uncertainty in Measurement group "constitute support the development of this regulation
Foundation norms. The procedures in the preparation of IEC 61098.2003 "Radiation protection instrumentation personnel surface contamination monitoring
Measuring device "(Radiationprotectioninstrumentation-Instaledpersonnelsurfacecontamination
monitoringassemblies), JJG 478-1996 "α, β, and γ the surface contamination meter", GB/T 8997-2008 "α,
β surface contamination meters and monitors calibration ", GB/T 5202-2008" Radiation protection instrumentation α, β and α/β
(Β energy greater than 60keV) contamination meters and monitors "as the main technical reference, and based on fixed α, β personal
Surface contamination monitoring device and the practical application of technical requirements and test methods to determine the work environment.
This procedure was first formulated.
Fixed α, β surface contamination test procedures personal monitoring device
1 Scope
The order applies to fixed α, β surface contamination personal monitoring device initial verification, verification and subsequent use
an examination.
This procedure does not apply to portable α, β surface contamination meters and monitors, as well as maximum energy less than 60keV
The β particles measuring or monitoring instrument calibration.
2. References
This procedure references the following documents.
JJG 478-1996 α, β, and γ the surface contamination meter
JJF1001-2011 common measurement terms and definitions
GB/T 4960.1-2010 nuclear science and technology terms - Part 1. Nuclear Physics and Chemistry
GB/T 4960.6-2008 nuclear science and technology - Part 6. Nuclear instrumentation
GB/T 5202-2008 Radiation protection instrumentation α, β and α/β (β energy greater than 60keV) contamination meters and
Monitor
GB/T 8997-2008 α, β surface contamination meters and monitors calibration
IEC 61098.2003 Radiation protection instrumentation personnel surface contamination monitoring device (Radiationpro-
tectioninstrumentation-Instaledpersonnelsurfacecontaminationmonitoringassem-
blies)
For dated references, only the dated edition applies to this specification; undated reference documents
Member, the latest edition (including any amendments units) applies to this procedure.
3 terminology and units of measurement
3.1 Terms
JJF1001-2011 "common measurement terms and definitions", GB/T 4960.6-2008 "nuclear science and technology terms
Part 6. Nuclear Instrumentation ", GB/T 4960.1-2010" Nuclear Science and Technology Terminology - Part 1. Nuclear Physics
And Nuclear Chemistry "and defined the following terms and definitions apply to this procedure.
3.1.1 response response
Under certain conditions, the response characteristic of incentives measuring instrument or device (system), and the value shown in the instrument
Energizing commercial representation. When the magnitude of radioactive sources to surface emissivity is represented, called surface emissivity response.
Consistency uniformityofresponse 3.1.2 Response
For fixed α, β personal surface contamination monitoring device, a plurality of detectors for detecting surface of the ring around
Relative deviation should be the reference point of the response to "%" means.
3.2 units of measurement
3.2.1 [radioactive] Activity. Becquerel [Bq]; symbol. Bq.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 1102-2014_English be delivered?Answer: Upon your order, we will start to translate JJG 1102-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJG 1102-2014_English with my colleagues?Answer: Yes. The purchased PDF of JJG 1102-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|