HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJG 1067-2011 English PDF

US$399.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJG 1067-2011: Verification Regulation of Medical Diagnostic X-ray Radiation Source for Medical Digital Subtraction Angiography
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 1067-2011English399 Add to Cart 3 days [Need to translate] Verification Regulation of Medical Diagnostic X-ray Radiation Source for Medical Digital Subtraction Angiography Valid JJG 1067-2011

PDF similar to JJG 1067-2011


Standard similar to JJG 1067-2011

GB/T 3222.1   JJG 188   JJF 1396   JJF 2017   JJF 1927   JJF 1067   

Basic data

Standard ID JJG 1067-2011 (JJG1067-2011)
Description (Translated English) Verification Regulation of Medical Diagnostic X-ray Radiation Source for Medical Digital Subtraction Angiography
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A58
Classification of International Standard 17.240
Word Count Estimation 17,130
Date of Issue 2011-06-14
Date of Implementation 2011-09-14
Quoted Standard IEC 61223-3-3-1996; IEC 60601-2-54; AAPM REPORT NO.15; GB 9706.23-2005; JJG 744-2004; YY/T 0740-2009; YY/T 0608-2007
Regulation (derived from) AQSIQ Announcement No. 90 of 2011
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to medical diagnostic digital subtraction angiography (Medical Digital Subtraction Angiography) (referred DSA) System X-ray radiation source of initial verification, testing and use of follow-up checks.

JJG 1067-2011: Verification Regulation of Medical Diagnostic X-ray Radiation Source for Medical Digital Subtraction Angiography


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Medical Diagnostic X-ray Radiation Source for Medical Digital Subtraction Angiography State verification procedures People's Republic of China Medical Diagnostic digital subtraction angiography (DSA) System X-ray radiation source Issued on. 2011-06-14 2011-09-14 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Medical Diagnostic digital subtraction angiography (DSA) System X-ray radiation source verification procedures The regulations by the State Administration of Quality Supervision, Inspection and Quarantine on June 14, 2011, approved and since From September 14, 2011 into effect. Focal point. the National Technical Committee of ionizing radiation metrology Main drafting unit. Beijing Institute of Metrology detection Jiangsu Province Institute of Metrology Participated in the drafting unit. Ministry of Health Hospital Management Institute Jiangsu Provincial People's Hospital Chinese Academy of Medical Sciences Cancer Hospital This procedure commissioned the National Technical Committee is responsible for ionizing radiation measurement interpretation The main drafters of this procedure. Tao (Beijing Institute of Metrology detection) Hu Shang Ze (Jiangsu Province Institute of Metrology) Pengming Chen (Ministry of Health, Hospital Management Institute) Hu Yibin (Jiangsu Provincial People's Hospital) Song Junfeng (Chinese Academy of Medical Sciences Cancer Hospital) Huang Xinsheng (Beijing Institute of Metrology detection) Drafters participate. Yao Shao Wei (Jiangsu Province Institute of Metrology)

table of Contents

1 Scope (1) 2. References (1) 3 terminology and units of measurement (1) 3.1 The term (1) 3.2 units of measurement (1) 4 Overview (2) 5 metering performance requirements (2) 5.1 air kerma rate (2) 5.2 Quality radiation output (2) 5.3 simulated blood vessels the minimum resolution size (2) Spatial resolution 5.4 (2) 5.5 low contrast resolution (2) 5.6 Contrast linear (2) 5.7 Save influence Movies performance (2) 5.8 X-ray tube voltage (2) 5.9 X-ray tube focus (2) 6 General Requirements (3) 6.1 Appearance and flags (3) 6.2 Electrical machinery and safety performance (3) 6.3 Technical Paper (3) 7 control of measuring instruments (3) 7.1 test conditions (3) 7.2 test items and test methods (4) 7.3 Verification Results Processing (7) 7.4 test cycle (7) Appendix A DSA performance measurement phantom technical requirements (8) Appendix B schematic slit camera (9) Appendix C test original record format (10) Appendix D calibration certificate and test results notice (within the page) format (11) Medical Diagnostic digital subtraction angiography (DSA) System X-ray radiation source verification procedures

1 Scope

The order applies to medical diagnostic digital subtraction angiography (MedicalDigitalSubtractionAngiography) (Referred to as DSA) system X-ray radiation source initial verification, subsequent verification and the use of checks. 2. References The regulations cited in the following documents. IEC 61223-3-3.1996 Digital subtraction angiography (DSA) X-ray imaging equipment performance acceptance tests First Edition IEC 60601-2-54. Medical electrical equipment - Part 2-54. ray radiography and fluoroscopy use X-ray equipment - Basic requirements and essential performance AAPMREPORTNo.15 digital subtraction angiography device performance evaluation and quality assurance GB 9706.23-2005 Medical electrical equipment - Part 2-43. Interventional X-ray equipment for the safety of the operation Claim JJG 744-2004 Medical Diagnostic X-ray emission test procedures YY/T 0740-2009 Medical angiography X-ray machine for the technical conditions YY/T 0608-2007 medical X-ray image intensifier television system General technical requirements When using this procedure, it should pay attention to the current valid version above referenced files.

3 terminology and units of measurement

3.1 Terms 3.1.1 Low contrast resolution lowcontrastresolution It can be separated and the ability to display images of low-contrast vessels from the background. 3.1.2 Spatial resolution spatialresolution In the images under high contrast conditions can distinguish between two adjacent objects ability. 3.1.3 ROI regionofinterest, ROI Image local region of particular interest. 3.1.4 Subtraction artifact subtraction-artifact Visible image, neither reflect the internal structure of the object, nor can the modulation transfer function or system noise To illustrate the texture. 3.2 units of measurement 3.2.1 air kerma rate units and symbols Unit. Ge [Swiss] per minute; symbol. Gy/min. 3.2.2 resolution units and symbols Unit. pairs per cm; symbol. Lp/cm.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 1067-2011_English be delivered?

Answer: Upon your order, we will start to translate JJG 1067-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 1067-2011_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 1067-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.