HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (6 Oct 2024)

JJG 1036-2022 English PDF

JJG 1036-2022_English: PDF (JJG1036-2022)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 1036-2022English429 Add to Cart 4 days [Need to translate] Electronic Balance Valid JJG 1036-2022
Standards related to: JJG 1036-2022

BASIC DATA
Standard ID JJG 1036-2022 (JJG1036-2022)
Description (Translated English) Electronic Balance
Sector / Industry Metrology & Measurement Industry Standard
Word Count Estimation 22,299
Date of Issue 2022-12-07
Date of Implementation 2023-06-07
Drafting Organization China Institute of Metrology
Administrative Organization National Mass Density Measurement Technical Committee
Proposing organization State Administration for Market Regulation

JJG 1036-2022 National Metrology Verification Regulations of the People's Republic of China Electronic balance Released on 2022-12-07 2023-06-07 Implementation Released by the State Administration for Market Regulation Electronic Balance Verification Regulations Replace JJG 1036-2008 Responsible unit. National Mass Density Measurement Technical Committee Main drafting unit. China Institute of Metrology Participating in the drafting unit. China Academy of Testing Technology Henan Institute of Metrology Zhejiang Institute of Metrology Mettler-Toledo Instruments (Shanghai) Co., Ltd. Shaanxi Institute of Metrology Shanxi Institute of Metrology This regulation entrusts the National Mass Density Measurement Technical Committee to be responsible for interpretation The main drafters of this regulation. Ding Jingan (National Institute of Metrology) Participating drafters. Dang Zhengqiang (China Academy of Testing Technology) He Kaiyu (Henan Institute of Metrology) Ge Rui (Zhejiang Institute of Metrology) Shen Xin [Mettler-Toledo Instruments (Shanghai) Co., Ltd.] Dong Lei (Shaanxi Institute of Metrology) Gao Ping (Shanxi Institute of Metrology) Table of contents Introduction (Ⅱ) 1 range(1) 2 References(1) 3 Terms and units of measurement(1) 3.1 Terminology(1) 3.2 Units of measurement(2) 4 Overview(2) 5 Metrological performance requirements (2) 5.1 Verification division value (2) 5.2 Accuracy classes(3) 5.3 Minimum capacity(3) 5.4 Multi-range balances(3) 5.5 Multi-interval balance(4) 5.6 Maximum permissible error(4) 5.7 Error calculation (5) 6 General technical requirements (5) 6.1 Marking(5) 6.2 Visual inspection (6) 6.3 General requirements for structure (6) 6.4 Temperature requirements(7) 6.5 Indication of weighing results (7) 6.6 Level indicator(7) 6.7 Zero setting device(8) 6.8 Zero tracking device (8) 6.9 Tare removal device(8) 7 Measuring Instrument Control(8) 7.1 Test conditions (8) 7.2 Preparation before verification (9) 7.3 Verification items (9) 7.4 Verification method (9) 7.5 Processing of test results (11) 7.6 Verification cycle (11) Appendix A Electronic Balance Verification Record Format (12) Appendix B Format of the inner page of the electronic balance verification certificate (15) Appendix C Internal Page Format of Electronic Balance Verification Result Notice (16) introduction This regulation is drafted in accordance with the rules of JJF1002-2010 "Rules for Compilation of National Metrology Verification Regulations", and the revised content Refer to the international recommendation OIMLR76-1 of the International Organization for Legal Metrology in terms of measurement performance requirements and main technical indicators. "Non-automatic Weighing Instruments Part 1.Measurement and Technical Requirements Test", (OIMLR76-1.2006Non- Test) and OIMLR76-2.2007 "Non-automatic Weighing Instruments Part 2.Test Report Format" (OIMLR76-2. Compared with JJG 1036-2008 "Electronic Balance", except for editorial revisions, the main technical changes are as follows. --- Increase the content of the "Introduction" part; ---Changes in the scope of application. only suitable for electronic balances with e≥1mg, others included in mass comparators or The scope of electronic balance calibration; ---Basically equivalent to the technical requirements of OIMLR76-1, for the text not clearly specified in OIMLR76-1 Partially expanded; --- Add JJG 99 and JJF1229 in "referenced documents"; --- In "terms and units of measurement", some necessary terms in the regulations have been added (such as 3.1.9 actual division value etc.), and increase the unit of measurement for special purposes; --- In the "Measurement Performance Requirements" section, add the provisions on the minimum number of verification divisions and the calculation of errors; --- Add the requirements for the balance warm-up period in the "General Technical Requirements" clause, and add explanatory marks; ---Added in the "Measuring Instrument Control" clause that the selected standard weights must follow JJG 99 "Weights" stipulations, and make specific requirements for the use of weights with correction values; ---Increase the number of measurements for the first verification in the "repeatability" verification; ---Increase the verification item of "Zero Setting Accuracy"; ---Increase the verification item of "tare weighing"; --- Modify Appendix A "Electronic Balance Verification Record Format"; --- Modify Appendix B "Format of the inner page of the electronic balance verification certificate"; ---Modify Appendix C "Format of the inner page of the electronic balance verification result notice". The previous releases of JJG 1036 are as follows. ---JJG 1036-2008 "Electronic Balance"; ---JJG 98-1990 "Non-automatic Balance". Electronic Balance Verification Regulations 1 Scope This regulation applies to the first verification and subsequent verification of electronic balances (hereinafter referred to as balances) with a verification division value e≥1 mg. Continuous verification and in-use inspection. 2 References This regulation refers to the following documents. JJG 99 Weights JJF1229 Mass Density Measurement Terminology OIMLR76-1.2006 Non-automatic Weighing Instruments Part 1.Measurement and Technical Requirements Test (OIML Requirement-Test) OIMLR76-2.2007 Non-automatic weighing instruments Part 2.Test report format (OIMLR76-2.2007 For dated references, only the dated version applies to this regulation; for undated references document, its latest version (including all amendments) applies to this regulation. 3 Terminology and units of measurement 3.1 Terminology 3.1.1 Zero-setting device A device for adjusting the indication to zero when there is no load on the balance pan. 3.1.2 zero-tracking device zero-trackingdevice A device that automatically maintains the zero indication within certain limits. 3.1.3 Taredevice A device for adjusting the indication to zero when a load is placed on the balance pan. There are two or more weighing ranges with different maximum loads and different actual division values, and each weighing range is Can be added from zero to the corresponding maximum load. 3.1.5 Multi-division balance multi-intervalinstrument There is only one weighing range, which is divided into several partial weighing ranges according to different actual division values. The local weighing range is the root It is automatically determined according to the increase or decrease of the applied load. 3.1.6 Maximum capacity maximumcapacity Max The maximum weighing capacity without adding tare. ...