HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJG 1013-2006 English PDF

US$519.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJG 1013-2006: Verification Regulation of γ Radiation Source Used in Head Stereotactic Radiosurgery Therapy
Status: Valid

JJG 1013: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 1013-2006English519 Add to Cart 4 days [Need to translate] Verification Regulation of γ Radiation Source Used in Head Stereotactic Radiosurgery Therapy Valid JJG 1013-2006
JJG 1013-1989EnglishRFQ ASK 3 days [Need to translate] Terms in common Use and Their Definitions for the Magnetic Metrorogy Obsolete JJG 1013-1989

PDF similar to JJG 1013-2006


Standard similar to JJG 1013-2006

GB/T 3222.1   JJG 188   JJF 1396   JJF 2017   JJF 1927   JJG 1009   

Basic data

Standard ID JJG 1013-2006 (JJG1013-2006)
Description (Translated English) Verification Regulation of �� Radiation Source Used in Head Stereotactic Radiosurgery Therapy
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A58
Classification of International Standard 17.240
Word Count Estimation 20,275
Date of Issue 2006-12-08
Date of Implementation 2007-03-08
Quoted Standard AQSIQ Announcement No. 187 of 2006
Regulation (derived from) AQSIQ Announcement No. 187 of 2006
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to the head stereotactic radiosurgery �� radiation treatment source initial verification, testing and use of follow-up inspection.

JJG 1013-2006: Verification Regulation of γ Radiation Source Used in Head Stereotactic Radiosurgery Therapy


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of γ Radiation Source Used in Head Stereotactic Radiosurgery Therapy National Metrology Verification Regulations of the People's Republic Head stereotactic radiosurgery Gamma radiation therapy source Released on.2006-12-08 2007-03-08 implementation The General Administration of Quality Supervision, Inspection and Quarantine issued Head stereotactic radiosurgery gamma radiation Treatment source verification procedure Py This verification procedure was approved by the General Administration of Quality Supervision, Inspection and Quarantine on December 8,.2006. And will be implemented as of March 8,.2007. Focal Point. National Ionizing Radiation Measurement Technical Committee Drafted by. China Institute of Metrology Participated in the drafting unit. Guangdong Province radiation dose measurement verification station This regulation is interpreted by the National Ionizing Radiation Measurement Technical Committee. The main drafters of this procedure. Hu Jiacheng (China Institute of Metrology) Participate in the drafters. Yang Xiaoyuan (China Institute of Metrology) Lu Yazhu (China Institute of Metrology) Peng Jiwei (Guangdong Radiation Dosimetry Verification Station)

table of Contents

1 Scope (1) 2 Citations (1) 3 terms and units of measurement (1) 3.1 Terminology (1) 3.2 Unit of measurement (2) 4 Overview (2) 5 Metrological performance requirements (2) 5.1 Radiation isocenter and mechanical isocenter consistency (2) 5.2 “Superimposed radiation field” (2) 5.3 “Superimposed penumbra” (3) 5.4 head gamma knife output dose (3) 6 General technical requirements (3) 6.1 Equipment Labels (3) 6.2 Device Display (3) 6.3 Safety requirements for treatment equipment (3) 7 Measuring instrument control (4) 7.1 Verification conditions (4) 7.2 Verification items and verification methods (6) 7.3 Processing of verification results (7) 7.4 Verification cycle (8) Appendix A Calculation Formula for Focus Absorbed Dose (9) Appendix B Evaluation of γ-knife focus dose measurement uncertainty (10) Appendix C Verification certificate page format (11) Appendix D Head gamma knife experiment report (1) (13) Appendix E Head gamma knife experiment report (2) (15) Head stereotactic radiosurgery gamma radiation treatment source verification procedure

1 Scope

This procedure is applicable to the first verification, subsequent verification and use of gamma radiation therapy sources for stereotactic radiosurgery of the head. test.

2 Citations

STEREOTACTICRADIOSURGERYSYSTEM , ReportofTaskGroup42Radiation TherapyCommittee.AAPMREPORTNo.54, June1995 [" Stereotactic radiosurgery system, put Report of the 42nd Working Group of the Radiation Therapy Committee, Technical Report of the American Association of Medical Physicists (AAPM) No. 54 (1995 edition)] Absorbeddosedeterminationinphotonandelectronbeams,Aninternationalcodeof Practice,SecondEdition,IAEATech.Rer.Ser.No.277,VIENNA1997 [Photon and Electronics Absorbed dose measurement of bundles, International Practical Regulations, IAEA Technical Report No. 277 (Second Edition,.1997)] JJF1001-1998 General Terms and Definitions JJF1059-1999 "Measurement and Expression of Measurement Uncertainty" JJG 912-1996 "Regulations for the verification of therapeutic level ionization chamber dosimeter" GB 191-90 "Package Storage and Transportation Graphic Mark" GB 4076-83 "General provisions for sealed radioactive sources" GB 5013.1-1997 "Rubber insulated flexible cable with rated voltage of 450/750V and below - Part 1. 1 General regulation GB 9706.1-1995 "Medical Electrical Equipment Part 1. General Requirements for Safety" GB/T 9969.1-1998 "General rules for the use of industrial products" GB/T 14710-93 "Environmental requirements and experimental methods for medical electrical equipment" YY0076-92 "Lamination classification and technical conditions of metal parts" YY0096-92 "Cobalt-60 Teletherapy Machine" GB/T 17857-1999 "Medical radiology terms (radiation therapy, nuclear medicine and radiation dosimetry equipment)"

3 terms and units of measure

3.1 Terminology 3.1.1 Collimator colimator A device that limits the direction of the beam and the size of the beam. 3.1.2 Focus Focus The center of the beam that is focused by the collimator is called the focus. 3.1.3 "Overlay radiation field" size "overlapingofirradiationfield" size a three-dimensional "superimposed radiation field" composed of a plurality of radiation sources arranged in a certain latitude and longitude, with a dose

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 1013-2006_English be delivered?

Answer: Upon your order, we will start to translate JJG 1013-2006_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 1013-2006_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 1013-2006_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 1013-2006?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 1013-2006 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.