US$379.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1950-2021: Calibration Specification for Thread Gauge Scanners Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| JJF 1950-2021 | English | 379 |
Add to Cart
|
4 days [Need to translate]
|
Calibration Specification for Thread Gauge Scanners
| Valid |
JJF 1950-2021
|
PDF similar to JJF 1950-2021
Basic data | Standard ID | JJF 1950-2021 (JJF1950-2021) | | Description (Translated English) | Calibration Specification for Thread Gauge Scanners | | Sector / Industry | Metrology & Measurement Industry Standard | | Classification of Chinese Standard | A52 | | Word Count Estimation | 16,159 | | Issuing agency(ies) | State Administration for Market Regulation |
JJF 1950-2021: Calibration Specification for Thread Gauge Scanners---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Thread Gauge Scanners
National Metrology Technical Specification of the People's Republic of China
Specification for calibration of thread gauge scanning gauges
Published on 2021-12-28
2022-06-28 Implementation
Released by the State Administration for Market Regulation
Specification for calibration of thread gauge scanning gauges
Focal Point. National Technical Committee on Geometric Length Measurement
Main drafting unit. China Institute of Metrology
Participating in the drafting unit. Shenzhen Zhongtu Instrument Technology Co., Ltd.
The Netherlands IAC Geometry Engineers
This specification entrusts the National Technical Committee of Geometry and Length Measurement to be responsible for the interpretation
The main drafters of this specification.
Wang Weinong (China Institute of Metrology)
Pei Limei (China Institute of Metrology)
Ren Guoying (China Institute of Metrology)
Wei Hengzheng (China Institute of Metrology)
Participating drafters.
Ma Junjie (Shenzhen Zhongtu Instrument Technology Co., Ltd.)
ReginaldGalestien (The Netherlands IAC Geometry Engineers)
Table of contents
Introduction (Ⅱ)
1 Scope(1)
2 References (1)
3 Terms and Definitions(1)
4 Overview(1)
5 Metrology Characteristics(2)
6 Calibration Conditions(2)
6.1 Environmental conditions (2)
6.2 Standard for calibration (3)
7 Calibration items and calibration methods (3)
7.1 Preparations (3)
7.2 Radial measurement indication error ΔD (3)
7.3 Detection error(3)
7.4 Taper measurement indication error ΔTP, ΔTR (4)
7.5 Indication error of cone diameter measurement ΔTDP, ΔTDR (4)
7.6 Thread parameter measurement indication error (4)
8 Expression of calibration results (5)
9 Recalibration interval(5)
Appendix A Raw Record Format(6)
Appendix B Example of Format of Inside Page of Calibration Certificate(9)
Appendix C Radial Measurement Indication Error Measurement Uncertainty Evaluation Example(10)
Appendix D Recommended Standard Diameter Fitting Series(11)
Introduction
JJF 1071-2010 "Rules for the Compilation of National Metrology Calibration Standards", JJF 1001-2011 "General Metrology Terms and
Definition" and JJF 1059.1-2012 "Measurement Uncertainty Evaluation and Representation" together constitute the revision of this calibration specification
The basic series of specifications.
This specification refers to GB/T 19600-2004 "Technical Specification for Product Geometric Quantity (GPS) Surface Structure Profile Method"
The measurement characteristics and methods in "Calibration of Contact (Stylus) Instruments", combined with the working principle of the thread gauge scanning measuring instrument
The combination and calibration method of the metrological characteristics are determined.
This specification is published for the first time.
Specification for calibration of thread gauge scanning gauges
1 Scope
This specification applies to the thread gauge scanning measuring instrument (hereinafter referred to as the thread
scanner) calibration.
2 Reference documents
This specification references the following documents.
JJF 1071-2010 Rules for Compilation of National Metrology and Calibration Specifications
ISO 14253-1.2017 Technical Specification for Geometric Quantities of Products (GPS) Measurement Inspection of Workpieces and Measuring Equipment
For dated references, only the dated version applies to this specification; for undated references
The latest version (including all amendments) applies to this specification.
3 Terms and Definitions
3.1 Indication error of radial measurement
The indication error of the thread scanner in the diameter direction of the thread gauge being measured.
3.2 Detection error
When scanning an ideal straight line or curve, the size and shape indication error measured by the thread scanner. by measuring
The dimensional measurement indication error and its variation of the quasi-cylinder at different positions are evaluated.
3.3 Indication error of taper measurement
The thread scanner measures the indication error of the taper of the smooth cone gauge. Using the error of the diameter change over the specified length
(mm/mm) expression.
3.4 Indication error of cone diameter measurement
When the thread scanner measures the smooth cone gauge, the diameter at the installation base surface (large end face of ring gauge, small end face of plug gauge)
indication error.
4 Overview
The thread scanner uses a fixture to position the thread gauge, so that the shaft section of the thread gauge and the probe of the thread scanner are aligned.
The needle movement planes coincide. The probe scans the profile surface on the axial section of the thread gauge, and collects the scan trajectory of the probe.
point set, and perform segmentation processing and mathematical calculation on the point set to obtain a single pitch diameter, pitch diameter, pitch, flank of the thread
The data of parameters such as angle and taper can also obtain the value of the effective diameter.
The size of the plane of motion of the probe depends on the radial and axial travel of the thread scanner.
Depending on the design, probe, fixture configuration and software, the thread gauge size,
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1950-2021_English be delivered?Answer: Upon your order, we will start to translate JJF 1950-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of JJF 1950-2021_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1950-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|