JJF 1406-2013: PDF in English

JJF 1406-2013 JJF NATIONAL TECHNICAL SPECIFICATIONS FOR MEASUREMENT OF THE PEOPLE’S REPUBLIC OF CHINA JJF 1406-2013 Calibration Specification for Terrestrial Laser Scanners ISSUED ON: MAY 13, 2013 IMPLEMENTED ON: AUGUST 13, 2013 Issued by: General Administration of Quality Supervision, Inspection and Quarantine Table of Contents Introduction ... 5 1 Scope ... 6 2 Normative References ... 6 3 Terms ... 6 3.1 Target ... 6 3.2 Absolute distance ... 6 3.3 Relative distance ... 6 3.4 Reference distance ... 6 3.5 Ball bar ... 7 4 Overview ... 7 5 Metrological Characteristics ... 8 5.1 Radial repeatability ... 8 5.2 Target repeatability ... 8 5.3 Indication error of radial distance ... 8 5.4 Indication error of spatial distance ... 8 6 Calibration Conditions ... 8 6.1 Environmental conditions ... 8 6.2 Etalon for calibration ... 8 6.3 Software used for calibration ... 9 7 Calibration Items and Methods ... 9 7.1 Indication error of radial distance ... 9 7.2 Radial repeatability ... 10 7.3 Target repeatability ... 11 7.4 Indication error of spatial distance ... 11 8 Calibration Results ... 13 9 Recalibration Time Interval ... 13 Appendix A Calibration Record and Calculation Table ... 14 Appendix B Inner Page Format of Calibration Certificate ... 16 Appendix C Evaluation of Measurement Uncertainty for Indication Error of Radial Distance ... 17 Appendix D Introduction of Calibration Device of Spatial Distance ... 20 Calibration Specification for Terrestrial Laser Scanners 1 Scope This Specification specifies the calibration method of static terrestrial laser scanner (hereinafter referred to as scanner), which is suitable for the calibration of pulse or phase scanner. Scanners of other principles may also be calibrated with reference to this Specification. 2 Normative References This Specification quotes the following document: JJF 1071-2010 The Rules for Drafting National Calibration Specification For the dated documents, only the versions with the dates indicated are applicable to this Specification; for the undated documents, only the latest version (including all the amendments) is applicable to this Specification. 3 Terms For the purpose of this specification, the following terms and definitions apply. 3.1 Target Scan target with geometric center and may be used for calibration. This Specification uses a spherical target. 3.2 Absolute distance The distance between the origin of the internal coordinate system of the instrument (the starting point of distance measurement) and the center of the target. 3.3 Relative distance The distance between target centers. 3.4 Reference distance The distance between target centers as a reference value. 5 Metrological Characteristics 5.1 Radial repeatability Under a set of repeatable measurement conditions, the measurement precision for the measured value of the absolute radial distance of the same fixed target. 5.2 Target repeatability Under a set of repeatable measurement conditions, the measurement precision for the measured value of the target center coordinate (point position). 5.3 Indication error of radial distance The difference between the measured value and the reference value of the relative distance along the measuring axis. 5.4 Indication error of spatial distance When scanning and measuring targets at different distances and orientations in space, the difference between the measured value and reference value of the relative distance. 6 Calibration Conditions 6.1 Environmental conditions Calibration shall be performed under the conditions specified by the manufacturer or agreed by the user. Ambient temperature and its rate of change shall affect the uncertainty of the calibration result and shall be considered in the uncertainty report. 6.2 Etalon for calibration It is recommended to use the measurement-calibration device or etalon listed in Table 1; and it is allowed to use other measurement-standard equipment that meets the uncertainty requirements for calibration. Table 1 -- Measurement-Calibration Equipment and Technical Requirements SN Measurement-calibration equipment and etalon Technical requirements 1 Target Diffuse reflection, non-transmission spherical target (aluminum products with sandblasted surface are recommended). The diameter is no less than 100mm, and the diameter change is no more than 0.1mm 2 Calibration device for radial distance Provides a series of linear reference distances covering the calibration range, such as moving a target from one location to floating guide rail is better than 0.5μm+0.5 ×10-6 L (k=2). When the measurement is estimated at the farthest 80 m, the standard uncertainty is as follows: C.4.2 The uncertainty component u2(Li) introduced by the measured value Li of the radial distance C.4.2.1 The uncertainty component u21(Li) introduced by the spherical target changing with temperature The aluminum spherical target with diameter of 200mm shall be used in the measurement; it has a temperature linear expansion coefficient of 23.6×10-6°C-1. Assuming that the temperature during calibration differs from the temperature of the spherical target by 5°C, it is uniformly distributed. According to the temperature correction formula, the standard uncertainty is as follows: C.4.2.2 The uncertainty component u22(Li) introduced by spherical target shape error The radius error of the spherical target shall cause the deviation of the spherical center coordinates. Through the calibration by the coordinate measuring machine, the maximum change in diameter is no more than 0.1mm; and it is uniformly distributed. The standard uncertainty introduced thereby is as follows: C.4.2.3 The uncertainty component u23(Li) introduced by the measurement repeatability of radial distance If the radial distance is repeatedly measured for at least 10 times, the uncertainty introduced by the repeatability is as follows: Combining the above three items, the uncertainty introduced by the measured value Li is as follows: ......
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.