JJF 1306-2011: Calibration Specification for X-Ray Fluorescence Coating Thickness Instruments
Status: Valid

JJF 1306: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1306-2011English329 Add to Cart 3 days [Need to translate] Calibration Specification for X-Ray Fluorescence Coating Thickness Instruments Valid JJF 1306-2011
JJF 1306-1990English199 Add to Cart 2 days [Need to translate] Operating technical norm of 3 cm, 5 cm coaxial thermal noise primary standard Obsolete JJF 1306-1990

PDF similar to JJF 1306-2011


Standard similar to JJF 1306-2011

JJF 1406   JJF 1280   JJF 1126   JJF 1305   JJF 1307   JJF 1304   

Basic data

Standard ID JJF 1306-2011 (JJF1306-2011)
Description (Translated English) Calibration Specification for X-Ray Fluorescence Coating Thickness Instruments
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A52
Classification of International Standard 17.040
Word Count Estimation 14,182
Date of Issue 2011-09-14
Date of Implementation 2011-12-14
Quoted Standard JJF 1001-1998; JJF 1059-1999; JJF 1094-2002; GB/T 16921-2005
Regulation (derived from) State Administration of Quality Supervision, Inspection and Quarantine Notice 2011 No. 134
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to the X-ray fluorescence coating thickness gauge calibration.

JJF 1306-2011: Calibration Specification for X-Ray Fluorescence Coating Thickness Instruments

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for X-Ray Fluorescence Coating Thickness Instruments People's Republic of China National Metrology Technical Specifications X-ray fluorescence coating thickness gauge calibration specification Issued on. 2011-09-14 2011-12-14 implementation The State Administration of Quality Supervision, Inspection and Quarantine released X-ray fluorescence coating thickness gauge calibration specification This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on September 14, 2011, and from From December 14, 2011 into effect. Focal point. the National Technical Committee of length measuring geometry Drafting units. China Institute of Metrology Shenzhen Academy of Metrology and Quality Inspection Skyray Instrument Co., Ltd. This specification length measuring geometry commissioned the National Technical Committee is responsible for interpretation The main drafters of this specification. Zhu Xiaoping (China Institute of Metrology) Wang Qiang Bing (Shenzhen Academy of Metrology and Quality Inspection) Li Hua (Jiangsu Skyray Instrument Co., Ltd.) Drafters participate. Du Hua (China Institute of Metrology) Wang Wei Chen (China Institute of Metrology)

table of Contents

1 Scope (1) 2. Referenced Documents (1) 3 Overview (1) 4 Metrological characteristics (1) 4.1 Thickness measurement repeatability (1) 4.2 shows the value of stability (1) 4.3 Thickness measurement indication error (1) Calibration Condition 5 (2) 5.1 environmental conditions (2) 5.2 calibration standard equipment and ancillary equipment (2) 6 calibration items and calibration methods (2) 6.1 Calibration preparation (2) 6.2 Thickness measurement repeatability (2) 6.3 shows the value of stability (2) 6.4 Thickness measurement indication error (3) 7 Calibration Results The expression (3) 8 recalibration intervals (3) Appendix A Evaluation of Uncertainty in Measurement (Example) (4) Appendix B Technical Requirements thickness standard blocks (7) Appendix C Common typical coating material thickness range (9) X-ray fluorescence coating thickness gauge calibration specification

1 Scope

This standard applies to X-ray fluorescence coating thickness gauge calibration.

2 Citations

This specification references the following documents. JJF 1001-1998 common measurement terms and definitions JJF 1059-1999 Evaluation and Expression of Uncertainty in Measurement JJF 1094-2002 measuring instrument characteristics evaluation GB/T 16921-2005 Metallic coatings - Measurement of coating thickness X-ray spectroscopy When using this specification it should be noted that using the currently valid version of the documents cited.

3 Overview

X-ray fluorescence coating thickness gauge is an energy dispersive method based on non-destructive quantitative analysis instrument with points Analysis of measuring a variety of metal materials composition and features a variety of coating thickness, widely used in electronics, semiconductor, jewelry, wood Analysis of materials and other industries. X-ray fluorescence coating thickness measurement of coating thickness principles. X-ray tube primary X On irradiation of the sample to be analyzed, the sample is excited to a secondary X-ray radiation to the detector, the second Energy radiation having a wavelength and characteristics of the sample material, coating thickness, and secondary radiation intensity of a certain relationship, the more Channel analyzer spectrum analysis and computer processing to calculate the coating thickness of the test sample. X-ray fluorescence coating thickness gauge working principle is shown in Figure 1. Figure 1 X-ray fluorescence coating thickness gauge working principle diagram

4 Metrological characteristics

4.1 Thickness measurement repeatability Coating thickness measurement repeatability of less than 3%. 4.2 shows the value of stability 1h shows the change in the value of the instrument is not greater than the maximum permissible indication error. 4.3 Thickness measurement indication error Technical agreement acceptance by users and manufacturers reached between the parties, when recalibration by the user's requirements. Note. Due to calibration measurements are given only, not qualified to judge whether or not the measuring properties are for reference only.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1306-2011_English be delivered?

Answer: Upon your order, we will start to translate JJF 1306-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1306-2011_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1306-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJF 1306-2011?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1306-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.