HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

JJF 1281-2011 English PDF

US$329.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1281-2011: Calibration specification for cut tobacco filling power tester
Status: Valid

JJF 1281: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1281-2011English329 Add to Cart 3 days [Need to translate] Calibration specification for cut tobacco filling power tester Valid JJF 1281-2011
JJF 1281-1990English199 Add to Cart 2 days [Need to translate] O.T.N. of the Primary Standard for Audiometric Zero Level of Bone Conduction Obsolete JJF 1281-1990

PDF similar to JJF 1281-2011


Standard similar to JJF 1281-2011

JJF 1406   JJF 1280   JJF 1126   JJF 1960   JJF 1367   

Basic data

Standard ID JJF 1281-2011 (JJF1281-2011)
Description (Translated English) Calibration specification for cut tobacco filling power tester
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A52
Classification of International Standard 17.040
Word Count Estimation 14,169
Date of Issue 2011-04-12
Date of Implementation 2011-07-12
Quoted Standard JJF 1001-1998; JJF 1094-2002; GB/T 18771.4-2002; JJF 1130-2005
Regulation (derived from) AQSIQ Announcement No. 58 of 2011
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to measuring range (0 ~ 30) mm tobacco fill value analyzer calibration.

JJF 1281-2011: Calibration specification for cut tobacco filling power tester

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration specification for cut tobacco filling power tester People's Republic of China National Metrology Technical Specifications Tobacco fill value analyzer calibration specification Issued on. 2011-04-12 2011-07-12 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Tobacco fill value analyzer calibration specification TobaccoFiling PowerTester This specification by the State Administration of Quality Supervision, Inspection and Quarantine approved on April 12, 2011, and from From July 12, 2011 into effect. NFP. National Engineering Geometrical Parameters Measurement Technology Committee Main drafting unit. Henan Institute of Metrology Henan Medical Device Testing China Tobacco Standardization Research Center Beijing Institute of Metrology detection Participated in the drafting unit. Henan tobacco industry limited liability company Zhengzhou Cigarette Factory Zhengzhou Guardian Electric Co., Ltd. This specification project commissioned by the National geometric parameter measurement technology committee responsible for the interpretation The main drafters of this specification. Zhang Weidong (Henan Institute of Metrology) Wang Dongmei (Henan Medical Device Testing) Yang Rong Chao (China Tobacco Standardization Research Center) Sun Jing Yi (Beijing Institute of Metrology detection) Drafters participate. Song Yongjie (Henan tobacco industry limited liability company Zhengzhou Cigarette Factory) Niu Gang (Zhengzhou Guardian Electric Co., Ltd.) Liu Xin (Henan Institute of Metrology)

table of Contents

1 Scope (1) 2. Referenced Documents (1) 3 Overview (1) 4 Metrological characteristics (1) 4.1 Measuring cylinder diameter (1) 4.2 Pressure (1) 4.3 pressing speed (2) 4.4 measuring cylinder and the bottom surface parallel to the urging of the probe measuring surface (2) 4.5 Repeatability (2) 4.6 Indication error (2) Calibration Condition 5 (2) 5.1 environmental conditions (2) 5.2 Calibration standard device and other equipment (2) 6 calibration items and calibration methods (3) 6.1 measuring tube inner diameter (3) Pressure of 6.2 (3) Pressing speed 6.3 (3) 6.4 Repeatability (3) 6.5 Indication error (3) 6.6 measuring cylinder and the bottom surface parallel to the urging of the probe measuring surface (4) 7 Calibration Results The expression (4) 8 Recalibration interval (4) Appendix A tobacco fill value detector indication error measurement Uncertainty Evaluation (5) Appendix B calibration certificate contents (8) Tobacco fill value analyzer calibration specification

1 Scope

This standard applies to the measurement range (0 ~ 30) mm tobacco fill value analyzer calibration.

2 Citations

This specification references the following documents. JJF 1001-1998 common measurement terms and definitions JJF 1094-2002 measuring instrument characteristics evaluation GB/T 18771.4-2002 tobacco Terminology Part IV. quality evaluation and testing JJF 1130-2005 geometric measurement equipment calibration Uncertainty Evaluation Guide When using this specification it should be noted that using the currently valid version of the documents cited.

3 Overview

Tobacco filling measuring instrument is a compression method with a constant weight measuring instruments measuring tobacco (stem) silk padding values. It measures the smoke (stem) by the displacement sensor wire to the top of the bottom of the standard cylindrical tube height values, calculate a certain quality of tobacco Silk filling value of tobacco by a certain pressure (see Figure 1) in the standard inside the cylinder. Depending on the measurement object, smoke Grass filling value of the tester into the tobacco filling value of the tester and the stem silk padding value of the tester two kinds.

1 tobacco fill value Schematic diagram of FIG tester

1- weights; 2,4-organism; 3- measuring cylinder; 5- urging probe; 6- guide post; 7- electric control box with digital display; 8- displacement sensor

4 Metrological characteristics

4.1 Measuring tube inner diameter Measurement of inner diameter shown in Table 1 technical requirements. 4.2 Pressure Tobacco filling pressure value analyzer technical requirements shown in Table 1.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1281-2011_English be delivered?

Answer: Upon your order, we will start to translate JJF 1281-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1281-2011_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1281-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJF 1281-2011?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJF 1281-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.