HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (29 Sep 2024)

JJF 1109-2003 English PDF

JJF 1109-2003_English: PDF (JJF1109-2003)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1109-2003English269 Add to Cart 3 days [Need to translate] Calibration Specification for Concentricity Tester Valid JJF 1109-2003
Standards related to: JJF 1109-2003

BASIC DATA
Standard ID JJF 1109-2003 (JJF1109-2003)
Description (Translated English) Calibration Specification for Concentricity Tester
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A52
Word Count Estimation 10,143
Date of Issue 2003-09-23
Date of Implementation 2004-03-23
Older Standard (superseded by this standard) JJG 88-1983
Drafting Organization Beijing Institute of Measurement Science
Administrative Organization National Technical Committee geometric length measurement
Regulation (derived from) State Administration of Quality Supervision, Inspection and Quarantine Notice 2003 No. 106
Issuing agency(ies) State Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to gear beating tester and deflection tester calibration.

JJF 1109-2003 Calibration Specification for Concentricity Tester National Metrology Technical Specification of the People's Republic Beat tester calibration specification Released on.2003-09-23 2004-03-23 implementation The General Administration of Quality Supervision, Inspection and Quarantine issued Beat tester calibration specification Concentricity Tester Replace JJG88-1983 This specification was approved by the General Administration of Quality Supervision, Inspection and Quarantine on September 23,.2003, and It will take effect on March 23,.2004. Focal Point. National Geometric Length Measurement Technical Committee Main drafting unit. Beijing Institute of Metrology Participated in drafting unit. China Institute of Metrology This specification entrusts the focal point to be responsible for interpretation The main drafters of this specification. Xia Yang (Beijing Institute of Metrology) Cui Zhenyu (Beijing Institute of Metrology) Participate in the drafters. Zhang Wei (China Institute of Metrology) Li Rui (China Institute of Metrology) table of Contents 1 range (1) 2 Citations (1) 3 Overview (1) 4 Measurement characteristics (2) 4.1 indicator table (2) 4.2 Parallelism of the longitudinal movement of the two top center lines to the slide (2) 4.3 Positional repeatability (2) 4.4 Parallelism of the fixed tip to the center of the active tip to the guide rail (2) 4.5 indication error (2) 5 Calibration conditions (2) 5.1 Environmental conditions (2) 5.2 Standard and other major equipment (3) 6 Calibration items and calibration methods (3) 6.1 Calibration of the indicator table (3) 6.2 Parallelism of the longitudinal movement of the two top center lines to the slide (3) 6.3 Positional repeatability (3) 6.4 Parallelism of the fixed tip to the center of the active tip to the guide rail (3) 6.5 indication error (3) 7 Calibration result expression (4) 8 re-study interval (4) Appendix A Calibration Certificate Page Format (5) Beat tester calibration specification 1 Scope This specification applies to the calibration of the gear runout tester and the yaw tester. 2 Citations The provisions contained in the following documents constitute provisions of this specification by reference in this specification. Publication of this specification The version shown is valid. All standards, specifications or procedures will be revised and all parties using this specification should Use the possibility of the latest version of the following literature. JJF 1001-1998 General measurement terms and definitions JJF 1059-1999 Measurement Uncertainty Evaluation and Representation GB/T 10095.2-2001 Involute cylindrical gears - Accuracy Part 2. Radial comprehensive deviation and radial runout Definition and allowable value GB/T 13924-1992 Involute cylindrical gear precision inspection specification GB/T 15481-2000 General requirements for calibration and inspection laboratory capabilities JJG34-1996 indication table (percent dial and dial gauge) verification procedures JJG39-1990 Mechanical comparator calibration procedures 3 Overview This type of instrument is mainly used to measure the ring runout of cylindrical gears, bevel gears and worm gears, as well as shafts, discs, etc. The radial circular runout of the rotating parts is shown in Figure 1, Figure 2. Figure 1 Gear Beat Checker ...