JJF 1102-2003: Calibration specification for bore dial indicators
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJF 1102-2003English469 Add to Cart 3 days [Need to translate] Calibration specification for bore dial indicators Valid JJF 1102-2003

PDF similar to JJF 1102-2003


Standard similar to JJF 1102-2003

JJG 1114   JJF 1280   JJF 1126   JJF 1097   JJF 1099   JJG 1102   

Basic data

Standard ID JJF 1102-2003 (JJF1102-2003)
Description (Translated English) Calibration specification for bore dial indicators
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A52
Word Count Estimation 18,193
Date of Issue 2003-05-12
Date of Implementation 2003-11-12
Older Standard (superseded by this standard) JJG 36-1989
Quoted Standard GB/T 8122-1987; JJS B7515-1982; JJF 1001-1998; JJF 1059-1999; JJG 34-1996; JJG 201-1999
Issuing agency(ies) State Administration of Quality Supervision, Inspection and Quarantine
Summary This standard applies to indexing is 0. 01mm, 0. 001mm, measuring range (2 to 450) calibration mm inner diameter of the table.

JJF 1102-2003: Calibration specification for bore dial indicators

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration specification for bore dial indicators National Metrology Technical Specification of the People's Republic Internal diameter table calibration specification Released on.2003-05-12 Implementation of.2003-11-12 The General Administration of Quality Supervision, Inspection and Quarantine issued Internal diameter table calibration specification Replace JJG36-1989 This specification was approved by the General Administration of Quality Supervision, Inspection and Quarantine on May 12,.2003, and Implemented on November 12,.2003. Focal Point. National Geometric Quantity Engineering Measurement Technology Committee Main drafting unit. China Testing Technology Research Institute This specification is interpreted by the focal point The main drafters of this specification. Chen Yongkang (China Testing Technology Research Institute) Zhaoqing (China Testing Technology Research Institute) Chang Yuyu (China Testing Technology Research Institute)

table of Contents

1 Scope (1) 2 Citations (1) 3 Overview (1) 4 Measurement characteristics (1) 4.1 Surface roughness of the measuring surface of the probe (1) 4.2 Spherical radius of the probe (1) 4.3 indicator table (1) 4.4 Working stroke of the active probe (1) 4.5 Force measurement of the movable probe and contact pressure of the positioning bridge (2) 4.6 Correctness of the centering device (3) 4.7 indication variability (3) 4.8 indication error and adjacent error (4) 5 Calibration conditions (5) 5.1 Environmental Conditions (5) 5.2 Calibration standard and corresponding equipment (5) 6 Calibration items and calibration methods (5) 6.1 Surface roughness of the measuring surface of the probe (5) 6.2 Spherical radius of the probe (5) 6.3 indicator table (5) 6.4 Working stroke of the active probe (5) 6.5 Force measurement of the movable probe and contact pressure of the positioning bridge (6) 6.6 Correctness of the centering device (6) 6.7 Indication variability (7) 6.8 indication error and adjacent error (7) 7 Calibration result expression (8) 8 re-study interval (8) Appendix A Calibration Certificate Contents (9) Appendix B Calculation Example of Correctness of Steel Ball Inner Diameter Dialing Center Setting Device (10) Appendix C Analysis of Uncertainty of Measurement Results of Internal Diameter Value Error (11) Internal diameter table calibration specification

1 Scope

This specification applies to internal diameter meters with a graduation value of 0.01 mm and 0.001 mm and a measurement range of (2 to 450) mm. calibration.

2 Citations

This specification refers to the following documents. GB/T 8122-1987 inner diameter dial gauge JJS.B7515-1982 Internal diameter dial gauge and internal diameter dial gauge JJF 1001-1998 General measurement terms and definitions JJF 1059-1999 Measurement Uncertainty Evaluation and Representation JJG34-1996 indication table verification procedure JJG201-1999 Verification procedure for indicating gauges Use of this specification should be done with the current valid version of the above cited documents.

3 Overview

The inner diameter gauge is an indicator table (percent dial or dial gauge) and a table set with a lever drive or linear drive A measuring instrument that converts a linear displacement of a measuring element into a pointer angular displacement or a numerical value. Mainly used for comparison Measure the inner diameter of the workpiece. According to its structure, it is divided into three types. positioning bridge (lever type or raceway type), spring type and steel ball type. Its shape is schematic The figures are shown in Figure 1, Figure 2 and Figure 3.

4 Measurement characteristics

4.1 Surface roughness of the measuring surface of the probe 4.1.1 Inner diameter table with positioning bridge can change the measuring head, the measuring surface of the movable probe and the surface of the contact bridge contact surface The roughness Ra does not exceed 0.2 μm. 4.1.2 The surface roughness Ra of the measuring surface of the spring probe of the spring type inner diameter meter shall not exceed 0.1 μm. 4.1.3 Measurement of the steel ball type inner diameter gauge The surface roughness Ra of the steel ball and the positioning steel ball does not exceed 0.05 μm. 4.2 Spherical radius of the probe The spherical radius of the interchangeable probe and the movable probe with the inner diameter gauge of the positioning bridge and the spherical half of the spring-loaded inner diameter gauge The diameter is less than 1/2 of the lower limit of the measurement. When comparing with a radius template of the corresponding size, a light gap appears on both sides of the template. 4.3 indicator The matching special indicator table complies with the requirements of JJG34-1996. 4.4 Working stroke of the active probe 4.4.1 Internal diameter dial gauge with positioning bridge The working stroke of the active probe is shown in Table 1.