Chinese Standards Shop Partner of Google-Books Database: 169760 (Nov 9, 2019)
 HOME   Quotation   Tax   Examples Standard-List   Contact-Us   View-Cart
  

JG 225-2007

Chinese Standard: 'JG 225-2007'
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusRelated Standard
JG 225-2007English110 Add to Cart 0--15 minutes. Auto immediate delivery. Corrugated metal dusts for prestressee concrete Valid JG 225-2007
JG 225-2007Chinese14 Add to Cart <=1-day [PDF from Chinese Authority, or Standard Committee, or Publishing House]

 JG 225-2007 -- Click to view a PDF In 0~10 minutes time, full copy of this English-PDF will be auto-immediately delivered to your email by our cloud-server.  
Detail Information of JG 225-2007; JG225-2007
Description (Translated English): Corrugated metal dusts for prestressee concrete
Sector / Industry: Building & Construction Industry Standard
Classification of Chinese Standard: H48
Classification of International Standard: 23.040.10
Word Count Estimation: 12,197
Date of Issue: 2007-09-04
Date of Implementation: 2008-02-01
Older Standard (superseded by this standard): JG/T 3013-1994
Quoted Standard: GB 716; GB/T 2518
Drafting Organization: ?China Architectural Scientific Academy
Administrative Organization: Ministry of Construction Engineering standard technical focal China Architectural Scientific Academy
Regulation (derived from): Chinese Ministry of Construction Bulletin No. 711
Summary: This standard specifies the prestressed concrete with a metal bellows classification and marking, requirements, test methods, inspection rules, packaging, marking, transportation, storage and use of such content. This standard applies to galvanized or not galvanized low carbon steel spiral made of folded seams and for post-tensioned concrete structure in the holes for the metal tube.

JG 225-2007
JG
CONSTRUCTION INDUSTRY STANDARD
OF THE PEOPLE’S REPUBLIC OF CHINA
Replacing JG/T 3013-1994
Corrugated metal ducts for prestressed concrete
预应力混凝土用金属波纹管
ISSUED ON. SEPTEMBER 4, 2007
IMPLEMENTED ON. FEBRUARY 1, 2008
Issued by. Ministry of Construction of the People's Republic of China
Table of Contents
Foreword ... 3 
1 Scope ... 5 
2 Normative references ... 5 
3 Classification and marking ... 5 
4 Requirements ... 6 
5 Test methods ... 9 
6 Inspection rules ... 13 
7 Packaging, marks ... 15 
8 Transport, storage ... 15 
9 Use ... 16 
Annex A (Informative) Quality inspection table of corrugated metal ducts for
prestressed concrete ... 17 
Annex B (Informative) Selection table of corrugated metal ducts for prestressed
concrete ... 18 
Foreword
4.5 and 4.6 of this Standard are mandatory; the rest are recommendatory.
Since the implementation of this Standard, it replaces JG/T 3013-1994 Metal
spiral sheath for prestressed concrete.
Compared with JG/T 3013-1994, main technical changes in this Standard are
as follows.
1. modified material requirements;
2. corrugated metal ducts are divided into standard type and enhanced type
according to rigidity; standard type and enhanced type are basically
identical; enhanced type is the content added;
3. added a clause about marking of corrugated metal ducts;
4. added the minimum overlap width of the folded seam of corrugated metal
ducts;
5. modified dimensional and tolerance requirements for round ducts and flat
ducts;
6. added minimum ripple height requirements of corrugated metal ducts;
7. added radial rigidity requirements of enhanced-type corrugated metal ducts;
8. modified the concentrated load value and uniform load value of radial
rigidity test of flat ducts;
9. modified radial rigidity test method of corrugated metal ducts;
10. modified resistance to leakage of the length of the specimen and test
method of corrugated metal ducts;
11. deleted the anti-leakage performance test of specimen after bearing
uniform load;
12. modified quality assurance documentation requirements for exit-factory
products;
13. improved product transport and storage requirements; added stack height
limit of corrugated metal ducts;
14. added use requirements;
15. merged and adjusted of relevant provisions;
16. modified an annex. Annex A Quality inspection table of corrugated metal
ducts for prestressed concrete which is informative;
17. added an annex. Annex B Selection table of corrugated metal ducts for
prestressed concrete which is informative.
This Standard was proposed by Institute of Standard Quota of Ministry of
Construction of China.
This Standard shall be under the jurisdiction of China Building Research
Institute (the jurisdiction organization specially for standard in construction
engineering of Ministry of Construction).
Main drafting organization of this Standard. China Building Research Institute.
The drafting organizations of this Standard. Zhejiang Institute of Architectural
Science Design & Research Co., Ltd., Kaifeng Strong Anchoring Technology
Co., Ltd., Henan Hongqiao Prestressed Manufacturing Co., Ltd.
Main drafters of this Standard. Li Dongbin, Dai Weiming, Huo Tingbo, Li Guozhu,
Qiao Yongli.
This Standard was issued on October 1994 for the first time. This is the first
revision.
Corrugated metal ducts for prestressed concrete
1 Scope
This Standard specifies the classification and marking, requirements, test
methods, inspection rules, packaging, marks, transport, storage and use of
corrugated metal ducts for prestressed concrete.
This Standard is applicable to metal ducts of reserved hole which are made by
plated or non-plated low-carbon steel with a screw folded seam and used in
post-tensioned prestressed concrete structural pieces.
2 Normative references
The following standards contain the provisions which, through reference in this
Standard, constitute the provisions of this Standard. For dated references,
subsequent amendments (excluding corrections) or revisions do not apply to
this Standard. However, the parties who enter into agreement based on this
Standard are encouraged to investigate whether the latest versions of these
documents are applicable. For undated reference documents, the latest
versions apply to this Standard.
GB 716 Cold-rolled carbon structural steel strips
GB/T 2518 Continuously hot-dip zinc-coated steel sheet and strip
3 Classification and marking
3.1 Classification
Corrugated metal ducts for prestressed concrete are divided into standard type
and enhanced type according to radial rigidity, round and flat according to
sectional shape, dual-wave and multi-wave according to the number of raised
corrugations between each two adjacent folded bites.
3.2 Marking
The mark of corrugated metal ducts for prestressed concrete consists of three
parts. code, diameter size and radial rigidity category.
4 Anti-leakage after concentrated load 3 5.4 4.6
5 Anti-leakage after bending 3 5.4 4.6
6.3 Type inspection
6.3.1 In case of one of the following situations, type inspection shall be
required.
a) stereotypes production identification of new products or old products to
the trial production;
b) after the official production, when great changes in materials, equipment,
technology, etc. may affect product performance;
c) type inspection should be carried out once every 2 years during normal
production;
d) when production is resumed after production discontinuation lasts for
more than six months;
e) great difference between exit-factory inspection results and the previous
type inspection;
f) when state quality supervision organization requires.
6.3.2 Batching
Among corrugated ducts of same corrugated amount, of same cross-sectional
shape, of same stiffness characteristics, select three products of typical
specifications for the inspection.
6.3.3 Sampling amount and inspection content are shown in Table 10.
Table 10 Content of type inspection
S/N Item name Sampling amount Test method
Qualification
criteria
1 Appearance 6 Visual inspection 4.2
2 Size 6 5.2 4.1, 4.4
3 Radial rigidity under concentrated load
6 5.3 4.5
4 Radial rigidity under uniform load
6 5.3 4.5
5 Anti-leakage after concentrated load
6 5.4 4.6
9 Use
9.1 During cast-in-place prestressing project, it shall use galvanized
corrugated metal ducts. During the production of prefabricated components,
when there is no corrosion of corrugated metal ducts, it shall use un- galvanized
corrugated metal ducts.
9.2 During prestressed concrete project, when it uses pre-beam through
process, it shall select standard type corrugated metal ducts; when it uses post-
beam through process, it shall use enhanced type corrugated metal ducts.
Enhanced type corrugated m......
Related standard:   JGJ/T 225-2010
   
 
Privacy   ···   Product Quality   ···   About Us   ···   Refund Policy   ···   Fair Trading   ···   Quick Response
Field Test Asia Limited | Taxed in Singapore: 201302277C | Copyright 2012-2019