JB/T 20051-2018: Herbal roaster
Status: Valid

JB/T 20051: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JB/T 20051-2018English229 Add to Cart 3 days [Need to translate] Herbal roaster Valid JB/T 20051-2018
JB/T 20051-2005English439 Add to Cart 3 days [Need to translate] Herbal medicine roaster Obsolete JB/T 20051-2005

PDF similar to JB/T 20051-2018


Standard similar to JB/T 20051-2018

GB/T 36030   JB/T 20032   JB/T 20104   JB/T 20053   JB/T 20052   JB/T 20050   

Basic data

Standard ID JB/T 20051-2018 (JB/T20051-2018)
Description (Translated English) Herbal roaster
Sector / Industry Mechanical & Machinery Industry Standard (Recommended)
Classification of Chinese Standard C93
Classification of International Standard 11.120.30
Word Count Estimation 10,130
Date of Issue 2018-07-04
Date of Implementation 2019-01-01
Older Standard (superseded by this standard) JB/T 20051-2005
Regulation (derived from) Ministry of Industry and Information Technology Announcement No. 36 of 2018
Issuing agency(ies) Ministry of Industry and Information Technology
Summary This standard specifies the terms and definitions, classification and marking, requirements, test methods, inspection rules and signs, instructions for use, packaging, transportation and storage of the speculative machine. This standard applies to electric heating fryers.

JB/T 20051-2018: Herbal roaster

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Rubber seals for headlights) ICS 11.120.30 C93 Record number. 64810-2018 People's Republic of China pharmaceutical machinery industry standard Replace JB/T 20051-2005 Stir-fry machine Herbalroaster Published on.2018-07-04 2019-01-01 implementation Ministry of Industry and Information Technology of the People's Republic of China

Foreword

This standard is drafted in accordance with the rules given in GB/T 1.1-2009 "Standardization Work Guide Part 1. Standard Structure and Compilation". The JB/T 20051-2005 "Fruit Machine" was revised. This standard replaces JB/T 20051-2005. Compared with JB/T 20051-2005, the main technical contents of this standard are as follows. --- Revised the normative reference document guide (see 2,.2005 edition 2). --- Revised product classification (see 4.1,.2005 edition 4.1). --- Revised the model preparation method (see 4.2,.2005 edition 4.2). --- Revised load bearing temperature and test method (see 5.3.3, 6.3.3,.2005 edition 5.3.3, 6.3.3). --- Revised electrical safety requirements and test methods (see 5.4,.2005 edition 5.4). --- Revised the type test conditions (see 7.3.1,.2005 version 7.3.1). --- Revised the contents of the instruction manual (see 8.2,.2005 edition 8.2). --- Added 8.3c) Material Certificate as specified in this standard. This standard was proposed by the China Pharmaceutical Equipment Industry Association. This standard is under the jurisdiction of the National Pharmaceutical Equipment Standardization Technical Committee (SAC/TC356). This standard was drafted. Zhoukou Pharmaceutical Machinery Factory Co., Ltd. The main drafters of this standard. Liu Xiaoguang, Han Gang, Zhao Liuzhu, Chang Jingjie. The previous versions of this standard were released as follows. ---JB/T 20051-2005. Stir-fry machine

1 Scope

This standard specifies the terms and definitions, classification and marking, requirements, test methods, inspection rules and signs, instructions for use, and packages of the speculative machine. Loading, transport and storage. This standard applies to electric heating fryers.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 191 packaging storage and transportation icon GB 5226.1-2008 Mechanical safety machinery and electrical equipment - Part 1. General technical conditions GB/T 6388 transport receipt and delivery mark GB/T 9969 General guidelines for the use of industrial products GB/T 10111 random number generation and its application in product quality sampling inspection GB/T 13306 signage General technical conditions for GB/T 13384 mechanical and electrical product packaging GB/T 16769 metal cutting machine noise sound pressure level measurement method GB/T 24342-2009 Industrial machinery electrical equipment protective earthing circuit continuity test specification JB/T 20188-2017 Pharmaceutical machinery product model preparation method Pharmacopoeia of the People's Republic of China (2015 Edition)

3 Terms and definitions

The following terms and definitions apply to this document. 3.1 Fried medicine machine herbalroaster A machine that indirectly heats the medicinal herbs. [GB/T 15692-2008, definition 6.3.2] 3.2 Horizontal fried medicine machine horizontalherbalroaster Stir-fry horizontally installed fry machine. [GB/T 15692-2008, definition 6.3.2.1] 3.3 Vertical fry machine verticalherbalroaster The fry pan is installed vertically and equipped with a mechanical stirrer. [GB/T 15692-2008, definition 6.3.2.3]