JB/T 20050-2018 English PDF

US$229.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JB/T 20050-2018: Herbal infiltrating machinery
Status: Valid

JB/T 20050: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JB/T 20050-2018English229 Add to Cart 3 days [Need to translate] Herbal infiltrating machinery Valid JB/T 20050-2018
JB/T 20050-2005English479 Add to Cart 3 days [Need to translate] Herbal medicine infiltrating machine Obsolete JB/T 20050-2005

PDF similar to JB/T 20050-2018


Standard similar to JB/T 20050-2018

GB/T 36030   JB/T 20032   JB/T 20104   JB/T 20053   JB/T 20052   JB/T 20051   

Basic data

Standard ID JB/T 20050-2018 (JB/T20050-2018)
Description (Translated English) Herbal infiltrating machinery
Sector / Industry Mechanical & Machinery Industry Standard (Recommended)
Classification of Chinese Standard C93
Classification of International Standard 11.120.30
Word Count Estimation 10,154
Date of Issue 2018-07-04
Date of Implementation 2019-01-01
Older Standard (superseded by this standard) JB/T 20050-2005
Regulation (derived from) Ministry of Industry and Information Technology Announcement No. 36 of 2018
Issuing agency(ies) Ministry of Industry and Information Technology
Summary This standard specifies the terms and definitions, classification and marking, requirements, test methods, inspection rules and signs, instructions for use, packaging, transportation and storage of the machine. This standard applies to pressure infiltration and vacuum infiltration of the drug machine.

JB/T 20050-2018: Herbal infiltrating machinery

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Thiamethoxam seed treatment suspension) ICS 11.120.30 C93 Record number. 64809-2018 People's Republic of China pharmaceutical machinery industry standard Replace JB/T 20050-2005 Runner machine Published on.2018-07-04 2019-01-01 implementation Ministry of Industry and Information Technology of the People's Republic of China

Foreword

This standard is drafted in accordance with the rules given in GB/T 1.1-2009 "Standardization Work Guide Part 1. Standard Structure and Compilation". The JB/T 20050-2005 "Running Machine" was revised. This standard replaces JB/T 20050-2005. Compared with JB/T 20050-2005, the main technical contents of this standard are as follows. --- Removed 5.1.2, 5.2.3, 6.3.5 of JB/T 20050-2005. --- Revised guidelines for normative references (see Chapter 2,.2005 Edition 2). --- Revised terms and definitions (see Chapter 3,.2005 edition 3). --- Revised product classification (see 4.1,.2005 edition 4.1). --- Revised model preparation (see 4.2.1,.2005 edition 4.2.1). --- Revised appearance, performance and experimental methods (see 5.2, 5.3,.2005 edition 5.2, 5.3). --- Revised electrical safety requirements and test methods (see 5.4,.2005 edition 5.4). --- Revised the type test conditions (see 7.3.1,.2005 version 7.3.1). --- Revised the contents of the instruction manual (see 8.2,.2005 edition 8.2). --- Increased the designated test samples and test methods for the quality test of the drug (see 6.5,.2005 edition 6.5). --- Added 8.3c) Material Certificate as specified in this standard. This standard was proposed by the China Pharmaceutical Equipment Industry Association. This standard is under the jurisdiction of the National Pharmaceutical Equipment Standardization Technical Committee (SAC/TC356). This standard was drafted. Zhoukou Pharmaceutical Machinery Factory Co., Ltd. The main drafters of this standard. Liu Xiaoguang, Han Gang, Zhao Liuzhu, Chang Jingjie. The previous versions of the standards replaced by this standard are. ---JB/T 20050-2005. Runner machine

1 Scope

This standard specifies the terms and definitions, classification and marking, requirements, test methods, inspection rules and signs, instructions for use, and packages of the drug-filling machine. Loading, transport and storage. This standard applies to pressure infiltration and vacuum infiltration of the drug machine.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 150.1~150.4-2011 Pressure vessel GB/T 191 packaging storage and transportation graphic standard GB 5226.1-2008 Mechanical safety machinery and electrical equipment - Part 1. General technical conditions GB/T 6388 packaging transport receipt and delivery mark GB/T 9969 General guidelines for the use of industrial products GB/T 10111 random number generation and its application in product quality sampling inspection GB/T 13306 signage General technical conditions for GB/T 13384 mechanical and electrical product packaging GB/T 24342-2009 Industrial machinery electrical equipment protective earthing circuit continuity test specification JB/T 20188 pharmaceutical machinery product model preparation method TSG21-2016 Safety Regulations for Fixed Pressure Vessels

3 Terms and definitions

The following terms and definitions apply to this document. 3.1 A machine in which water vapor contacts the medicinal material and penetrates into the tissue to expand the volume and weaken the mechanical strength. [Modify 6.2.1 of GB/T 15692-2008] 3.2 Pressurized medicine machine pressedherbalmaterialinfiltratingmachine Pressurizing machine that pressurizes water vapor into the medicinal tissue. [Modify 6.2.1.2 of GB/T 15692-2008] 3.3 Vacuum medicine machine vacuumherbalinfiltratingmachine The gas in the interstitial space of the medicinal material is extracted by a negative pressure, and then the water vapor is passed through the medicinal machine. [Modify 6.2.1.1 of GB/T 15692-2008]

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JB/T 20050-2018_English be delivered?

Answer: Upon your order, we will start to translate JB/T 20050-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JB/T 20050-2018_English with my colleagues?

Answer: Yes. The purchased PDF of JB/T 20050-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JB/T 20050-2018?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JB/T 20050-2018 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.