US$314.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 9331-2008: Single and multicore non-radial field power cables with extruded solid insulation for rated voltages 1kV and 3 kV Status: Valid GB/T 9331: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 9331-2008 | English | 314 |
Add to Cart
|
3 days [Need to translate]
|
Single and multicore non-radial field power cables with extruded solid insulation for rated voltages 1kV and 3 kV
| Valid |
GB/T 9331-2008
|
| GB 9331.1-1988 | English | RFQ |
ASK
|
9 days [Need to translate]
|
Shipboaer power cables and wires of rated voltages up to and including 0. 6/1 KV--General
| Obsolete |
GB 9331.1-1988
|
PDF similar to GB/T 9331-2008
Basic data | Standard ID | GB/T 9331-2008 (GB/T9331-2008) | | Description (Translated English) | Single and multicore non-radial field power cables with extruded solid insulation for rated voltages 1kV and 3 kV | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K13 | | Classification of International Standard | 29.060.20 | | Word Count Estimation | 16,148 | | Date of Issue | 2008-06-30 | | Date of Implementation | 2009-04-01 | | Older Standard (superseded by this standard) | GB 9331.1-1988 | | Adopted Standard | IEC 60092-353-1995, IDT | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 11 of 2008 (No. 124 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard applies to fixed laying rated voltage 0. 6/1 (1. 2) kV and 1. 8/3 (3. 6) kV (see 2. 1) extruded insulation marine power cable. The structure of various types of cable requirements see 3. 1. Unless otherwise specified in this standard, structural requirements and test methods shall comply with structural requirements and test methods should be consistent with GB/T 20637-2006 requirements. |
GB/T 9331-2008: Single and multicore non-radial field power cables with extruded solid insulation for rated voltages 1kV and 3 kV ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Single and multicore non-radial field power cables with extruded solid insulation for rated voltages 1kV and 3 kV
ICS 29.060.20
K13
National Standards of People's Republic of China
GB/T 9331-2008/IEC 60092-353.1995
Replacing GB 9331.1-1988
Electrical installations in ships
Rated voltage Vp 1 k and 3 k Vp extruded insulation non-radial
Single and multi-core field power cables
(IEC 60092-353.1995, IDT)
Posted 2008-06-30
2009-04-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Overview 1
2 2 General requirements
3 structural requirements 2
4 6 test requirements
Enhanced insulation thickness Annex A (informative) rated voltage 450/750V cable alternative 8
Annex B (informative) Model 9
Annex C (informative) The Standard Model and JB/T 8140.1 ~ 8140.2 and 8140.4-1995 model representation
Control 10
GB/T 9331-2008/IEC 60092-353.1995
Foreword
This standard is identical with IEC 60092-353 "Ship for rated voltages 1kV and 3kV extruded insulation single non-radial electric field
Core and multi-core power cables, "(1995, in English), No. 2001, which amendments are included in the content of the text, and they are involved in article
Paragraph margin identified by the vertical wire.
For ease of use, this standard made the following editorial changes.
--- Remove the IEC 60092-353 foreword;
"." --- With a decimal point instead of a comma as the decimal point, "";
--- IEC IEC 60092-350 referenced in the original terms of the corresponding error number, has according to GB/T 20637-2006 terms into numbers
Line the appropriate changes;
--- Increase the informative Appendix A and Appendix B data to guide use.
Since the implementation of this standard replaces GB 9331.1-1988 "rated voltage 0.6/1kV ships Shipboard power cables and wires
Provisions ", compared with the present standard GB 9331.1-1988 The main changes are as follows.
--- Standard name was changed to "Ship for rated voltages 1kV and 3kV extruded insulation non-radial electric field single and multi-core
Power cable ";
--- Scope changed to "suitable for fixed installation rated voltage of 0.6/1 (1.2) kV and 1.8/3 (3.6) kV extruded insulation boat
Power cable "(1988 version 1.1; this version 1.1);
--- Specifies the type of insulating material and a mixture of uses (edition 2.2 and 3.1);
--- Insulation canceled mixture of natural SBR insulation (edition 2.2);
--- Specifies the type of material and the use of a mixture of the sheath (edition 2.3 and 3.1);
--- Provides cable marking shall "and have made Made rated voltage" (1988 version 9.11, this version 2.4.1);
--- Increasing the continuity and durability requirements of flags, and specifies the test methods (Excerpts 2.4.2,2.4.3 and 4.1.2);
--- Specifies the use of metal shielding principle (edition 3.1 and 3.6);
--- Specifies the thickness (this version 3.5.2) in the sheath;
--- Canceled armor layer metal tape armor (version 1988 8.4.3.3);
--- Provides 1.8/3kV cable 5min voltage test voltage values \u200b\u200b(see Table 3);
--- Flame test and performance requirements referenced in IEC 60332-3 bunched Class A requirements (see IEC 60092-350 in 13.5)
[1988 version 9.6.2; this edition 4.2.4f)];
--- Increase the smoke density test halogen-free cable insulation and jacketing materials [Excerpts 4.2.4g)];
--- Canceled watertight performance test requirements (1988 version 9.8);
--- Canceled the length of cable delivery, testing and acceptance, packaging requirements (Edition 1988 Chapter 10, Chapter 11 and Chapter 12);
--- Increase the informative appendix "rated voltage 450/750V cable alternative enhanced insulation thickness" (see the edition of Appendix A);
--- Canceled the 1988 version of Appendix A;
--- Increase the informative appendix "Product Name" (see the edition of Appendix B);
--- Canceled the 1988 version of Annex B;
--- Modify the product family code (1988 version 4.1.1, this version of Appendix B.1.1);
--- Canceled conductor Code (1988 version 4.1.2);
--- Modify the insulation series code (1988 version 4.1.3, this version of Appendix B.1.2);
--- Modify jacket series code (1988 version 4.1.4, this version of Appendix B.1.3);
--- Modify the combustion characteristics symbol (version 4.1.5 1988, edition of Appendix B.1.4);
GB/T 9331-2008/IEC 60092-353.1995
--- Modify the product representation (version 4.2.1 1988, edition of B.2);
--- Increase the informative appendix "The Standard Model and JB/T 8140.1 ~ 8140.2 and 8140.4-1995 Model represent
Collation method "(see the edition of Appendix C);
--- Remove Appendix G "galvanized steel plating adhesion test method", K "watertight test" appendix;
--- Mechanical and physical properties of the finished cable and associated test methods for cable materials not given in detail (version 1988 in the appendix
Appendix C, Appendix D, Appendix E, Appendix F, Appendix H, Appendix I, Appendix J, this version 4.2.4).
The Standard Appendix A, Appendix B and Appendix C are informative appendix.
The standard proposed by China Electrical Equipment Industrial Association.
This standard by the national wire and cable Standardization Technical Committee (SAC/TC213) centralized.
This standard is drafted by. Shanghai Electric Cable Research Institute.
Participated in the drafting of this standard. Baosheng Science and Technology Innovation Co., Ltd., Changzhou Marine Cable Co., Ltd., Fujian Nanping Sun Electric
Cable Co., Ltd., Jiangsu Cable Group, Jiangsu Ocean Dongze Cable Group Limited, a wire and cable Tianjin Jinshan shares
the company.
The main drafters of this standard. Guo Han Yang, Zhou Jian, GAO Jun, Van der hair, sand Wei Lu Yunchun, Zheng Guojun.
This standard replaces the standards previously issued as follows.
--- GB 9331.1-1988.
GB/T 9331-2008/IEC 60092-353.1995
Electrical installations in ships
Rated voltage Vp 1 k and 3 k Vp extruded insulation non-radial
Single and multi-core field power cables
1 Overview
1.1 Scope and purpose
This standard applies to fixed installation rated voltage of 0.6/1 (1.2) kV and 1.8/3 (3.6) kV (see 2.1) extruded insulation marine power electricity
cable.
NOTE. If necessary, fire resistant (to maintain the integrity of the line under certain conditions) the terms of the cable has been developed.
Structure of the various types of cable requirements of section 3.1. Unless otherwise specified in this standard, the structure should meet the requirements and test methods
GB/T 20637-2006 requirements.
The purpose of this standard.
--- Designed to press GB/T 13029.1-2003 requirements when laying, safety and reliability are guaranteed cable energy standardization;
--- Directly or indirectly, the safety provisions of the laying, production requirements and characteristics of this type of cable;
--- Specifies the test methods to check compliance with these requirements.
1.2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 156-2003 standard voltage (IEC 60038. 1983, NEQ)
GB/T 2951-1997 (all parts) cable insulation and sheathing materials test methods (idt IEC 60811)
GB/T 13029.1-2003 Electrical installations in ships low-voltage power cable systems selection and installation (IEC 60092-352.
1997, IDT)
Test equipment. GB/T 17651.1-1998 of cables burning under defined conditions - Part 1 smoke density determination
(Idt IEC 61034-1.1997)
GB/T 17651.2-1998 of cables burning under defined conditions Measurement of smoke density - Part 2. Test procedure and requirements
(Idt IEC 61034-2.1997)
GB/T 19216.11-2003 in Circuit integrity under fire conditions - electric cables - Part 11. Apparatus - Fire
Temperature not lower than 750 ℃ \u200b\u200bfor a separate fire (IEC 60331-11.1999, IDT)
GB/T 19216.21-2003 in Part 21 Circuit integrity under fire conditions - cable or fiber optic cable. To test procedure and
Seek rated voltage 0.6/1kV and below cables (IEC 60331-21.1999, IDT)
GB/T 19666-2005 retardant and fire-resistant wire and cable General
GB/T 20637-2006 Electrical installations in ships shipboard power cables - General construction and test requirements (IEC 60092-350.
2001, IDT)
IEC 60092-351.2004 Electrical installations in ships and marine oil platforms with power, control, instrumentation, communication and data cables must
Insulating material
IEC 60092-359.1999 Electrical installations in ships shipboard power and telecommunication cables with sheathing material
1.3 Definitions
Definitions GB/T 20637-2006 apply to this standard.
GB/T 9331-2008/IEC 60092-353.1995
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 9331-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 9331-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 9331-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 9331-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 9331-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 9331-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|