HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (26 Oct 2025)

GB/T 4854.8-2007 English PDF

US$214.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 4854.8-2007: Acoustics -- Reference zero for the calibration of audiometric equipment -- Part 8: Reference equivalent threshold sound pressure levels for pure tone and circumaural earphones
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 4854.8-2007English214 Add to Cart 3 days [Need to translate] Acoustics -- Reference zero for the calibration of audiometric equipment -- Part 8: Reference equivalent threshold sound pressure levels for pure tone and circumaural earphones Valid GB/T 4854.8-2007

PDF similar to GB/T 4854.8-2007


Standard similar to GB/T 4854.8-2007

GB/T 3222.2   GB/T 3222.1   GB/T 4854.7   GB/T 4854.3   GB/T 4854.9   GB/T 4854.6   

Basic data

Standard ID GB/T 4854.8-2007 (GB/T4854.8-2007)
Description (Translated English) Acoustics -- Reference zero for the calibration of audiometric equipment -- Part 8: Reference equivalent threshold sound pressure levels for pure tone and circumaural earphones
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard A59
Classification of International Standard 17.140
Word Count Estimation 11,113
Date of Issue 2007-11-14
Date of Implementation 2008-05-01
Quoted Standard GB/T 4854.1; GB/T 7584.1; GB/T 7341.2; IEC 60318-1-1998; IEC 60318-2-1998
Adopted Standard ISO 389-8-2004, IDT
Regulation (derived from) China Announcement of Newly Approved National Standards No. 12 of 2007 (No. 112 overall)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the frequency range 125Hz ~ 8000Hz pure tone reference equivalent threshold sound pressure levels for a special model with earphones air conduction audiometry equipment calibration. Appendix B shows that earphones sound attenuation. Appendix C gives the AE and BE classes language classes audiometer headphones free field equivalent output correction value.

GB/T 4854.8-2007: Acoustics -- Reference zero for the calibration of audiometric equipment -- Part 8: Reference equivalent threshold sound pressure levels for pure tone and circumaural earphones



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Acoustics Reference zero for the calibration of audiometric equipment Part 8. Reference equivalent threshold sound pressure levels for pure tone and circumaural earphones ICS 17.140 A59 National Standards of People's Republic of China GB/T 4854.8-2007/ISO 389-8.2004 Acoustics - Reference zero for the calibration of audiometric equipment Part 8. Headphones pure tone benchmarks, etc. SPL threshold effect (ISO 389-8.2004, IDT) Posted 2007-11-14 2008-05-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Preface Ⅰ Introduction Ⅱ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 technical requirements Appendix A (informative) obtained HDA200 on type headphones circumaural audiometry Reference equivalent threshold sound pressure levels of note 3 Sound Appendix B (Informative Appendix) HDA200 headphones attenuation 4 Correction value Appendix C (Informative Appendix) HDA200 type Headphones free field equivalent output of 5 Reference 6 GB/T 4854.8-2007/ISO 389-8.2004

Foreword

GB/T 4854 "acoustic calibration of audiometric equipment - Reference zero" includes eight parts. --- Part 1. the ear headphones pure tone reference equivalent threshold sound pressure levels (GB/T 4854.1); --- Part 2. pure tones and insert earphones Reference equivalent threshold sound pressure levels (GB/T 16402); --- Part 3. pure tones and bone vibrators Reference equivalent threshold force levels (GB/T 4854.3); --- Part 4. Reference levels for narrow-band masking noise (GB/T 4854.4); Part --- Article 5. 8kHz ~ 16kHz frequency range of pure tone reference equivalent threshold sound pressure levels (GB/T 4854.5); --- Part 6. short duration of the test signal reference equivalent threshold sound pressure levels; --- Part 7. Reference free field and diffuse - field listening hearing threshold (GB/T 4854.7); --- Part 8. Headphones pure tone reference equivalent threshold sound pressure levels (GB/T 4854.8). This section GB/T Section 84854 of. This part identical with ISO 389-8.2004 "Reference zero for the Section 8 acoustic calibrator audiometric equipment. Headphones pure sound base Quasi-equivalent threshold sound pressure levels "(in English). This section is equivalent to using international standards made editorial changes. This part of the Annex A, Annex B and Annex C is informative appendix. This section proposed by the Chinese Academy of Sciences. The acoustics in part by the National Standardization Technical Committee (SAC/TC17) centralized. This section is drafted. PLA General Hospital Institution of Otorhinolaryngology, Institute of Acoustics. The main drafters of this section. Chen Hongwen, Wu Wenming, at dawn, Zhang Yu Wei, Dai Genhua. GB/T 4854.8-2007/ISO 389-8.2004

Introduction

The enactment of this section, in order to be able to use the same headset 125Hz ~ 16000Hz frequency range for pure tone audiometry. This section It specifies the reference value of 125Hz ~ 8000Hz, GB/T 4854.5 defines the reference value of 8000Hz ~ 16000Hz. The reference value is based on the most reliable data available laboratories in different countries can be provided at the time determined. Currently, these reference values only for SENNHEISERHDA200 this kind of model of earphones. This headset for background noise Sound good sound attenuation, and its frequency response in the human ear and ear simulator there is no obvious resonance. GB/T 4854.8-2007/ISO 389-8.2004 Acoustics - Reference zero for the calibration of audiometric equipment Part 8. Headphones pure tone reference equivalent threshold sound pressure levels

1 Scope

This section provides a frequency range of 125Hz ~ 8000Hz pure tone reference equivalent threshold sound pressure levels (RETSPLs), equipped with a suitable A special type of earphones (SENNHEISERHDA200) of air conduction audiometry calibration equipment. Note. This paper presents results HDA200 type Headphones Reference equivalent threshold sound pressure levels and test conditions described in Annex A and references. Appendix B gives the sound attenuation of this ear headphones. Appendix C gives A-E and Class B-E Language audiometer (see Free field GB/T 7341.2) headphone output equivalent correction value.

2 Normative references

The following documents contain provisions which, through reference to GB/T 4854 to the present, constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB/T 4854.1 acoustic calibration of audiometric equipment - Reference zero - Part 1. the ear headphones pure tone reference equivalent threshold sound pressure levels (GB/T 4854.1-2004, ISO 389-1.1998, IDT) Subjective method of measurement of sound attenuation (GB/T 7584.1-2004,. GB/T 7584.1 Hearing protectors - Part 1 ISO 4869-1.1990, IDT) GB/T 7341.2 Audiometers - Part 2. Language audiometric equipment (GB/T 7341.2-1998, idt IEC 60645-2.1993) IEC 60318-1.1998 electric acoustic head and ear simulator - Part 1. Align the ear headphones with ear simulator IEC 60318-2.1998 electric acoustic head and ear simulator - Part 2. Calibration extends the high frequency range audiometer headphones Pro When the acoustic coupling chamber

3 Terms and Definitions

This part of GB/T 4854.1, GB/T 7341.2, GB/T 7584.1 and IEC 60318-1.1998 The terms and definitions. 4. Technical Requirements Coupled cavity or ear simulator Reference equivalent threshold sound pressure levels and the adapter with the headset model and calibration headphones using. Table 1 to A closed type earphones SENNHEISER HDA200 type with IEC 60318-1.1998 and the provisions of the ear simulator IEC 60318-2.1998 benchmark adapter measured predetermined Figure 1 equivalent threshold sound pressure levels. GB/T 4854.8-2007/ISO 389-8.2004

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 4854.8-2007_English be delivered?

Answer: Upon your order, we will start to translate GB/T 4854.8-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 4854.8-2007_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 4854.8-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information