HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (26 Oct 2025)

GB/T 4854.5-2008 English PDF

US$194.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 4854.5-2008: Acoustics -- Reference zero for the calibration of audiometric equipment -- Part 5: Reference equivalent threshold sound pressure levels for pure tone in the frequency range 8 kHz to 16 kHz
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 4854.5-2008English194 Add to Cart 3 days [Need to translate] Acoustics -- Reference zero for the calibration of audiometric equipment -- Part 5: Reference equivalent threshold sound pressure levels for pure tone in the frequency range 8 kHz to 16 kHz Valid GB/T 4854.5-2008

PDF similar to GB/T 4854.5-2008


Standard similar to GB/T 4854.5-2008

GB/T 3222.2   GB/T 3222.1   GB/T 4854.7   GB/T 3241.2   GB/T 4854.3   GB/T 4854.9   

Basic data

Standard ID GB/T 4854.5-2008 (GB/T4854.5-2008)
Description (Translated English) Acoustics -- Reference zero for the calibration of audiometric equipment -- Part 5: Reference equivalent threshold sound pressure levels for pure tone in the frequency range 8 kHz to 16 kHz
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard A59
Classification of International Standard 17.140
Word Count Estimation 10,157
Date of Issue 2008-07-02
Date of Implementation 2009-02-01
Adopted Standard ISO 389-5-2006, IDT
Regulation (derived from) Announcement of Newly Approved National Standards No. 11 of 2008 (No. 124 overall)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the 8kHz ~ 16kHz frequency range of pure tone reference equivalent threshold sound pressure levels (RETSPLs), a specific model for air conduction headset audiometer calibration.

GB/T 4854.5-2008: Acoustics -- Reference zero for the calibration of audiometric equipment -- Part 5: Reference equivalent threshold sound pressure levels for pure tone in the frequency range 8 kHz to 16 kHz



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Acoustics Reference zero for the calibration of audiometric equipment Part 5. Reference equivalent threshold sound pressure levels for pure tone in the frequency range 8 kHz to 16 kHz ICS 17.140 A59 National Standards of People's Republic of China GB/T 4854.5-2008/ISO 389-5.2006 Acoustics - Reference zero for the calibration of audiometric equipment Part 5. 8 k H z ~ 16 k H z frequency Range pure tone reference equivalent threshold sound pressure levels (ISO 389-5.2006, IDT) Posted 2008-07-02 2009-02-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

GB/T 4854 "acoustic calibration of audiometric equipment - Reference zero" includes eight parts. --- GB/T 4854.1 acoustic calibration of audiometric equipment - Reference zero for Part 1. the ear headphones pure tone reference equivalent threshold sound Pressure level; --- GB/T 16402 Acoustics pure tones and insert earphones Reference equivalent threshold sound pressure levels; --- GB/T 4854.3 acoustic calibration of audiometric equipment - Reference zero - Part 3. pure tones and bone vibrators Reference equivalent threshold force levels; --- GB/T 4854.4 Acoustics - Reference zero for the calibration of audiometric equipment - Part 4. Reference levels for narrow-band masking noise; --- GB/T 4854.5 acoustic calibration of audiometric equipment - Reference zero - Part 5. 8kHz ~ 16kHz frequency range of pure tones Reference equivalent threshold sound pressure levels; --- GB/T 4854.6 Acoustics - Reference zero for the calibration of audiometric equipment - Part 6. short test drive signal reference hearing threshold level; --- GB/T 4854.7 Section 7 Reference zero acoustic calibrator audiometric equipment. free-field and diffuse - field listening base Quasi hearing threshold; --- GB/T 4854.8 acoustic calibration of audiometric equipment - Reference zero - Part 8. Headphones pure tone reference equivalent threshold sound Pressure level. Note. In developing this standard Part 2, our country has not yet formed a series of standards, the standard number is GB/T 16402, in the part of the revision of its Standard will be changed to GB/T 4854.2. This section GB/T 54854 Part of. This part identical with ISO 389-5.2006 "Acoustics --- calibration of audiometric equipment - Reference zero --- Part 5. 8kHz ~ 16kHz frequency range pure tone reference equivalent threshold sound pressure levels "(in English). This section is equivalent to using international standards made editorial changes. Appendix A of this section and Appendix B is an informative annex. This section proposed by the Chinese Academy of Sciences. The acoustics in part by the National Standardization Technical Committee (SAC/TC17) centralized. This section drafted by. Institute of Otolaryngology, Chinese PLA General Hospital, Chinese Academy of Sciences Institute of Acoustics. The main drafters of this section. Chen Hongwen, at dawn, Wu Wenming, Dai Genhua, Zhang Yu Wei. This section first release. GB/T 4854.5-2008/ISO 389-5.2006

Introduction

National Standard GB extended high frequency audiometry device/T 7341.4 has been promulgated. As the high-frequency range extending calibration audiometry using headphones Adapter with IEC 60318-1 ear simulator used together to form the acoustic coupler calibration middle-ear headphones. The adapter has now become International Standard IEC 60318-2 (will be included in the revised IEC 60318-1). This section describes specific model Headphones And insert earphones reference equivalent threshold sound pressure levels, can be used for these models have been equipped with headphones calibrated audiometer, hearing threshold level in our country Expression measurements values \u200b\u200bconsistent with internationally. GB/T 4854.5-2008/ISO 389-5.2006 Acoustics - Reference zero for the calibration of audiometric equipment Part 5. 8 k H z ~ 16 k H z frequency Range pure tone reference equivalent threshold sound pressure levels

1 Scope

This section provides 8kHz ~ 16kHz frequency range pure tone reference equivalent threshold sound pressure levels (RETSPLs), for a particular type ear Air conduction audiometer calibration machine. NOTE. it gives a description and experimental conditions to determine the reference equivalent threshold sound pressure levels in Appendix A and reference.

2 Normative references

The following documents contain provisions which, through reference to GB/T 4854 to the present, constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated references, the latest version applies to This section. GB/T 4854.1 acoustic calibration of audiometric equipment - Reference zero - Part 1. the ear headphones pure tone reference equivalent threshold sound pressure levels (GB/T 4854.1-2004, ISO 389-1.1998, IDT) GB/T 16402 Acoustics pure tones and insert earphones Reference equivalent threshold sound pressure levels (GB/T 16402-1996, eqv ISO 389-2. 1994) IEC 60318-11) electro-acoustics simulator head and ear - Part 1. Align the ear headphones ear simulator IEC 60318-2.19982) electro-acoustics simulator head and ear - Part 2. Calibration extended high-frequency audiometry intermediate range headphones Acoustic coupler IEC 607113) and insert earphones measurement clogged ear simulator

3 Terms and Definitions

This part of GB/T 4854.1 and IEC 60318-1 terms and definitions in. 4. Technical Requirements Reference equivalent threshold sound pressure levels (RETSPLs) headset model and calibration headset with an ear simulator and adapter related. Table 1 to Out (ETYMOTICRESEARCHER-2 with ER1-14A type earplugs) and close to two different types of headphones [insert earphones Predetermined value closed earphones (SENNHEISERHDA200)] of. Headband SENNHEISERHDA200 type earphones clamping force should be (10.0 ± 1.0) N. When measuring headband clamping force, two ears The distance between the machine should be 145mm; headband center (top) from the midpoint of the center of two headphones to be adjusted to 130mm. Ear ETYMOTICRESEARCHER-2 plug-in headset, should be deep into a subject's ear canal, so earplugs The outer end of the ear canal flush. 1) is being revised. 2) will be canceled, its content is included in the revised IEC 60318-1. 3) will become the IEC 60318-4. GB/T 4854.5-2008/ISO 389-5.2006

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 4854.5-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 4854.5-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 4854.5-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 4854.5-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information