HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (6 Jul 2025)

GB/T 4750-2016 English PDF

US$599.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 4750-2016: Criteria for designing of household anaerobic digesters
Status: Valid

GB/T 4750: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 4750-2016English599 Add to Cart 5 days [Need to translate] Criteria for designing of household anaerobic digesters Valid GB/T 4750-2016
GB/T 4750-2002EnglishRFQ ASK 8 days [Need to translate] Collection of standard design drawings for household anerobie digesters Obsolete GB/T 4750-2002
GB/T 4750-1984EnglishRFQ ASK 14 days [Need to translate] The collection of designs for household hydraulic biogas digesters in rural areas Obsolete GB/T 4750-1984

PDF Samples

Basic data

Standard ID GB/T 4750-2016 (GB/T4750-2016)
Description (Translated English) Criteria for designing of household anaerobic digesters
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard F18
Classification of International Standard 27.180
Word Count Estimation 30,319
Date of Issue 2016-10-13
Date of Implementation 2017-05-01
Older Standard (superseded by this standard) GB/T 4750-2002
Regulation (derived from) National Standard Notice No.1716 of 2016
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People Republic of China, China National Standardization Administration Committee

Similar standards

GB/T 29729   GB/T 29838   GB/T 29411   GB/T 4752   GB/T 4751   

GB/T 4750-2016: Criteria for designing of household anaerobic digesters

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Criteria for working of householdanaerobic digesters ICS 27.180 F19 National Standards of People's Republic of China Replacing GB/T 4750-2002 Household biogas digesters design specifications 2016-10-13 released 2017-05-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Management Committee released Directory Preface I 1 Scope 1 2 normative reference document 1 3 specification content 1 4 Use condition 3 5 security measures 3 6 quality inspection 3 Appendix A (Normative Appendix) Material Legend, Legend Symbol, Commonly Used Name 4 Appendix B (informative) Partial household biogas digesters Specific design requirements 6 B.1 masonry cloth biogas digesters 6 B.2 Swirl cloth biogas digesum 17 B.3 Separation of gas storage bucket biogas digesters 19 B.4 Prefabricated reinforced concrete slabs equipped with biogas digesters B.5 biogas digesters, poultry, pig house, toilet "three combined" arrangement 27 Figure B.1 masonry cloth biogas digesters type A pool type Figure 8 Figure B.2 masonry cloth biogas digesters detail (type A) 9 Figure B.3 Masonry cloth biogas digesters B type pond Figure 10 Figure B.4 masonry cloth biogas digesters detail (type B) 11 Figure B.5 masonry cloth biogas digesters C type pond Figure 12 Figure B.6 masonry cloth biogas digesters detail (type C) 13 Figure B.7 Masonry cloth biogas digesters Figure 14 Figure B.8 Masonry cloth biogas digesters Figure 15 Figure B.9 Component Figure 16 Figure B.10 Swirl cloth biogas digesum 18 Figure B.11 Separating the aerosol buoy Figure B.12 Prefabricated reinforced concrete slabs equipped with biogas digesters Figure B.13 Prefabricated reinforced concrete slabs equipped with biogas digesters Figure B.14 Prefabricated reinforced concrete slabs equipped with biogas digesters Figure B.15 Prefabricated reinforced concrete slabs equipped with biogas digesters Figure B.16 Prefabricated reinforced concrete slabs equipped with biogas digesters Figure B.17 Schematic diagram of the three-in-one arrangement of biogas digesters, poultry, pig houses and toilets Table A.1 Material Legend 4 Table A.2 Illustration Symbol 4 Table A.3 Commonly used names 5

Foreword

This standard and GB/T 4752-2016 and GB/T 4751-2016 and the proposed "household biogas digesters operation and maintenance norms" common Constitute a household biogas digesters design, construction, acceptance, operation of the series of national standards. This standard is drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces GB/T 4750-2002 "household biogas digesters standard Atlas", compared with GB/T 4750-2002 main technology change As follows. --- increased the type of fermentation between the pool and the structural design requirements; --- modified air tightness, working pressure, test air pressure, maximum air pressure limit; --- to modify the unit effective volume of gas production, life and safety measures; --- increase the swirl cloth biogas digesters design; --- increase the engineering plastics, glass fiber reinforced plastics and other new materials commercial biogas products refer to the application of the relevant content; - the material legend, symbol symbols, commonly used name as a normative appendix; - the application of the original standard map is more extensive, is still suitable for the actual pool and the current type of absorption of the new pool are classified as informative appendix. Please note that some of the contents of this document may involve patents. The issuer of this document does not assume responsibility for the identification of these patents. This standard is proposed by the Ministry of Agriculture. This standard is nationalized by the National Biogas Standardization Technical Committee (SAC/TC515). The drafting unit of this standard. Ministry of Agriculture, Agricultural Ecology and Resource Protection Station, Kunming Energy Research Association, Northwest A & F University, Ministry of Agriculture marsh Gas Products and Equipment Quality Inspection Center, China Biogas Society, Yunnan Normal University. The main drafters of this standard. Li Jingming, Zhang Wanjun, Qiu Ling, Zheng Shihuan, Xie Jian, Dong Baocheng, Sun Liying, Liu Geng, Li Bingfeng, Xu Wenyong, Liu Xinqing. This standard replaced the previous version of the standard release. GB/T 4750-1984, GB/T 4750-2002. Household biogas digesters design specifications

1 Scope

This standard specifies the design specifications of the household biogas digesters and the design requirements and indicators of the necessary supporting facilities. This standard is applicable to the design, construction and production of biogas digesters for concrete, brick and concrete, engineering plastics and glass fiber reinforced plastics.

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. Code for acceptance of quality inspection of biogas digesters GB/T 4751 Code of practice for construction of biogas digesters GB/T 4752 households

3 specification content

3.1 pool type of various parts of the structure 3.1.1 Fermentation structure Should use the same volume of timber less, both inside and outside the force is reasonable, favorable liquid flow, not easy to produce dead space, easy processing, transportation, construction And the use of the structure of the management of the shape, examples, symbols see Appendix A, the structure of the shape see Appendix B. 3.1.2 inlet and outlet pipes The diameter of the inlet and outlet pipes is in the range of.200mm ~ 300mm. When the concrete prefabricated pipe is used, the inner diameter should not be less than 250mm, Tube, the diameter should not be less than.200mm. Into the flow of material in principle, the requirements of the outflow, special terrain, if the fermentation room is not effective Diversion device, the inlet and outlet pipe (mouth) horizontal projection angle of not less than 120 °. 3.1.3 days window, activity cover Household biogas digesters set up day window, activity cover. The shape can be selected according to the type of the tank and the construction process. round, oval, positive Square, rectangular and other shapes; sealing can be bottle-type, flat-type positive cover (that is, from the top cover), anti-cover (that is, from the next cover). See attached Record B, Figure B.9 Component diagram. 3.1.4 between the hydraulic pressure The effective volume of the pressure between the biogas digesters is not less than 50% of the daily production. According to the plane shape can be divided into. round, oval, square Shaped, rectangular, according to the pool type, built pool terrain according to local conditions should be designed. In the material can be discharged in the direction of the overflow should be provided. 3.1.5 gas storage The effective volume of the gas storage cover of the separated biogas digesters is not less than 50% of the daily production capacity.
......