HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (15 Jun 2025)

English GB/T 42920-2023 PDF

Search result: GB/T 42920-2023
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 42920-2023English499 Add to Cart 5 days [Need to translate] Plastics - Assessment of the fire characteristics and fire performance of fibre-reinforced plastic composites Valid GB/T 42920-2023


BASIC DATA
Standard ID GB/T 42920-2023 (GB/T42920-2023)
Description (Translated English) Plastics - Assessment of the fire characteristics and fire performance of fibre-reinforced plastic composites
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard G31
Classification of International Standard 83.080.01
Word Count Estimation 26,254
Date of Issue 2023-08-06
Date of Implementation 2024-03-01
Issuing agency(ies) State Administration for Market Regulation, National Standardization Administration


GB/T 42920-2023. Evaluation of fire resistance and fire resistance of plastic fiber reinforced plastic composite materials ICS 83.080.01 CCSG31 National Standards of People's Republic of China Fire resistance properties of plastic fiber reinforced plastic composites and Assessment of fire performance Published on 2023-08-06 2024-03-01 Implementation State Administration for Market Regulation Released by the National Standardization Administration Committee Table of contents PrefaceⅠ 1 range 1 2 Normative reference documents 1 3 Terms and Definitions 1 4 fiber reinforced materials 2 5 Fire resistance properties 3 6 Fire test methods 6 Appendix A (informative) Comparison table 8 between this document and ISO 25762.2009 structure numbers Appendix B (informative) Typical tests of glass fiber reinforced plastic composites by ISO and EN fire test methods Result 9 Appendix C (informative) Procedures for handling fiber-reinforced plastic composite materials in case of fire 15 Appendix D (informative) Recommendations for processing and storage of fiber reinforced plastic composites16 Appendix E (informative) Determination of heat release rate of fiber reinforced plastic composite materials 17 Appendix F (informative) Installation and fixation of fiber reinforced plastic composite specimens 19 Reference 22 Preface This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1.Structure and Drafting Rules of Standardization Documents" Drafting. This document is modified to adopt ISO 25762.2009 "Fire resistance characteristics and fire performance evaluation of plastic fiber reinforced polymer composites" guide". Compared with ISO 25762.2009, this document has many structural adjustments. A comparison list of structural number changes between the two documents See Appendix A. The technical differences between this document and ISO 25762.2009 and their reasons are as follows. ---Replaced ISO 472 (see Chapter 3) with normatively quoted GB/T 2035 to adapt to my country's technical conditions; ---Replaced ISO 13943 with normatively quoted GB/T 5907.1~GB/T 5907.3 (see Chapter 3); ---Change Note 2 of the term "composite materials" in ISO 25762.2009 to the text (see 3.1); ---Change the term "radiation resistance" in ISO 25762.2009 to Note 1~Note 3 of 5.2.1 (see 5.2.1); ---Deleted the terms "smoke growth rate index", "thermoset material", "thermoplastic material" and "reinforced fiber" in ISO 25762.2009 and definition; ---Change the term "fiber-reinforced polymer composite material" to "fiber-reinforced plastic composite material" (see 3.2) to adapt to my country's technology technical conditions; ---Change the notes in ISO 25762.20096.2 to the text (see 6.2); ---Change "ISO Fire Safety Technical Committee (ISO /TC92)" to "National Fire Safety Technical Committee (SAC/TC113)" (See 6.4), to adapt to my country’s technical conditions; ---Change ISO 25762.20093.1.10 to the note in Table B.3 (see Table B.3). The following editorial changes have been made to this document. ---In order to coordinate with the existing standards, the name of the standard is changed to "Fire resistance characteristics and fire performance of plastic fiber reinforced plastic composite materials" assessment"; ---Deleted Note 3 "Related guidance on handling fires in fiber-reinforced polymer composites" in the scope of ISO 25762.2009 to and fire safety management, handling and storage recommendations for fiber reinforced plastic composites” (see Chapter 1); ---Replaced ISO 5660-1 with informative reference GB/T 16172 (see 3.7, 5.1.4, 6.3, Appendix B and Appendix E) to adapt my country’s technical conditions; ---Replaced ISO 1268 (all parts) with the informative reference GB/T 27797 (all parts) (see 4.4) to adapt to our country's Technical conditions; ---Replaced ISO 1182 (see 5.1.2) with the informative reference GB/T 5464 to adapt to my country's technical conditions; ---Replaced ISO 24473 (see 5.1.4 and Appendix E) with the informative reference GB/T 41382 to adapt to my country's technical conditions; ---Replaced ISO 9705 with the informative reference GB/T 25207 (see 5.1.4, 5.2.2, 6.4 and Appendix E) to adapt to my country's Technical conditions; ---Replaced ISO 9239-1 (see 5.1.5) with the informative reference GB/T 11785 to adapt to my country's technical conditions; ---Replaced ISO 5658-2 (see 5.1.5 and Appendix B) with the informative reference GB/T 28752 to adapt to my country's technology condition; ---Replaced ISO 5659-2 (see 5.1.6, 5.1.7 and Appendix B) with the informative reference GB/T 8323.2 to adapt to my country's technology technical conditions; ---Replaced ISO 834 (all parts) with the informative reference GB/T 9978 (all parts) (see 5.2, 6.5, Appendix B and Appendix F), to adapt to my country’s technical conditions; ---Replaced ISO 13784-1 (see 6.4) with the informative reference GB/T 25206.1 to adapt to my country's technical conditions; ---Replaced ISO 13784-2 (see 6.4) with the informative reference GB/T 25206.2 to adapt to my country's technical conditions; ---Deleted Note 2 in ISO 25762.20096.5 "ISO 30021-2, Medium-scale fire resistance test of fiber-reinforced polymer composites Standard, which is currently under development,” and the ISO 30021 standard has been transformed into a national standard. ---Added Appendix A (informative) "List of comparison between this document and ISO 25762.2009 structure numbers"; Please note that some content in this document may be subject to patents. The publisher of this document assumes no responsibility for identifying patents. This document is proposed by China Petroleum and Chemical Industry Federation. This document is under the jurisdiction of the National Plastics Standardization Technical Committee (SAC/TC15). This document was drafted by. Zhonglan Chenguang Chemical Research and Design Institute Co., Ltd., Chengdu Product Quality Inspection Institute Co., Ltd., Fuzhou Jian Provincial Product Quality Inspection Institute, Huafeng Group Co., Ltd., Zhejiang Plite New Materials Co., Ltd., Zhejiang Ruigao New Materials Co., Ltd. Company, Nanjing Jiangning Analytical Instrument Co., Ltd., Xihua University, CGN Juner (Zhejiang) New Materials Co., Ltd., Chongqing International Composite Materials Stock Co., Ltd., Xinchuang Carbon Valley Group Co., Ltd., Liaocheng University, East China University of Science and Technology Huachang Polymer Co., Ltd., Zhejiang World Expo New Materials Co., Ltd. Co., Ltd., Jilin Provincial Product Quality Supervision and Inspection Institute, Ningbo Jujia New Material Technology Co., Ltd., Meixin Technology Co., Ltd., Shenzhen Langbowan Advanced Materials Co., Ltd., Guangdong Shunde Shunyan New Materials Co., Ltd., Ningbo Yijia Chemical Fiber Technology Co., Ltd., Guangdong Tai Plastic New Material Technology Co., Ltd., Xinrun New Material Technology (Jiangsu) Co., Ltd. The main drafters of this document. Ma Chaoqiang, Fu Jingwei, Wei Min, Yao Zengwen, Zhao Liping, Zhao Junhuan, Wang Fuhai, Li Guangming, Li Jun, Zhang Yanjun, Liu Qi, Tan Kunlun, Teng Mouyong, Liu Hua, Tu Dan, Li Shangyu, Wang Xiao, Wang Yang, Lin Dongrong, Kang Hongwei, Zhang Ping, Shen Litao, Li Ang, Wei Xin, Zhang Haisheng, Ji Yongjing, Zhang Yang. Fire resistance properties of plastic fiber reinforced plastic composites and Assessment of fire performance 1 Scope This document describes the fire resistance properties and fire resistance of fiber-reinforced plastic (FRP) composites for structural applications in construction and transportation. Ability assessment methods. This document applies to fiber-reinforced thermosetting or thermoplastic plastic composites with inorganic fiber lengths greater than 7.5mm. This document describes the following evaluation methods. ---The suitability of different product types (such as panels, laminates, profiles and certain sandwich structures) for end-use performance; ---Test methods and performance judgment basis for fiber-reinforced plastic samples with different shapes. Note 1.The physical form (such as thickness, density and shape) of fiber-reinforced plastic composites varies widely. Note 2.Fiber-reinforced plastic composites can also be products that also contain other materials (such as metal or inorganic non-fiber fillers), as well as air gaps, joints, etc. Components for sewing and fastening accessories. 2 Normative reference documents The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, the dated quotations For undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to this document. GB/T 2035 Plastic terms and definitions (GB/T 2035-2008, ISO 472.1999, IDT) GB/T 5907.1 Fire protection vocabulary Part 1.General terms GB/T 5907.2 Fire Vocabulary Part 2.Fire Prevention GB/T 5907.3 Fire Vocabulary Part 3.Fire Fighting and Rescue 3 Terms and definitions The following terms and definitions as defined in GB/T 2035 and GB/T 5907.1~GB/T 5907.3 apply to this document. 3.1 composite materialcomposite Two or more different phase materials, at least one of which is a matrix material that is a plastic or organic polymer and forms a structured group of continuous phases Composite materials. Note. Composite materials have a single-layer structure or a multi-layer structure. 3.2 A composite material composed of thermosetting or thermoplastic resin and fibers with a length greater than 7.5 mm before processing. Note. In this document, plastic composite materials containing fibers with a pre-processing length of 7.5 mm or less are not considered fiber-reinforced plastic composite materials. 3.3 load-bearingcapacity load-bearingcapacity The ability of a product to maintain its structural stability after one or more sides have been exposed to flame for a period of time. ......

Similar standards: GB/T 42976   GB/T 42977   GB/T 42924.1   GB/T 42918.2