HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 41074-2021 English PDF

US$284.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 41074-2021: Microbeam analysis - Method of specimen preparation for analysis of general powders using WDS and EDS
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 41074-2021English284 Add to Cart 3 days [Need to translate] Microbeam analysis - Method of specimen preparation for analysis of general powders using WDS and EDS Valid GB/T 41074-2021

PDF similar to GB/T 41074-2021


Standard similar to GB/T 41074-2021

GB/T 40244   GB/T 35924   GB/T 35930   GB/T 41072   GB/T 41064   

Basic data

Standard ID GB/T 41074-2021 (GB/T41074-2021)
Description (Translated English) Microbeam analysis - Method of specimen preparation for analysis of general powders using WDS and EDS
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard G04
Word Count Estimation 14,170
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 41074-2021: Microbeam analysis - Method of specimen preparation for analysis of general powders using WDS and EDS


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Microbeam analysis -- Method of specimen preparation for analysis of general powders using WDS and EDS ICS 71:040:99 CCSG04 National Standards of People's Republic of China Microbeam Analysis for Spectroscopy and Energy Spectroscopy Powder sample preparation method (ISO 20720:2018, IDT) Published on 2021-12-31 2022-07-01 Implementation State Administration for Market Regulation Released by the National Standardization Administration directory Preface III Introduction IV 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Abbreviations 1 5 Sample preparation method 1 6 Conductive treatment 6 Appendix A (Informative) Example 7 of the Influence of Pressure on the Intensity of Tablet X-rays Appendix B (Informative) Example 8 of the Effect of Particle Size on Tablet X-ray Intensity Reference 9

foreword

This document is in accordance with the provisions of GB/T 1:1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents" Drafting: This document is identical to ISO 20720:2018 "Microbeam Analysis Method for Preparation of Powder Samples for Spectroscopic and Energy Dispersive Analysis": Please note that some content of this document may be patented: The issuing agency of this document assumes no responsibility for identifying patents: This document is proposed and managed by the National Microbeam Analysis Standardization Technical Committee (SAC/TC38): This document is drafted by: Institute of Mineral Resources, Chinese Academy of Geological Sciences, Beijing Institute of Geology of Nuclear Industry, Chinese Academy of Sciences of Geology and Geology Institute of Ball Physics: The main drafters of this document: Chen Zhenyu, Fan Guang, Mao Qian:

Introduction

Although Electron Probe (EPMA) and Scanning Electron Microscopy (SEM) are widely used in powder analysis, there are some difficulties, especially in In the case of single particle analysis, such as: a) particle agglomeration during sample preparation; b) fixation of the specimen, especially when a small amount of fine particles is present for surface analysis or cross-sectional analysis; c) Cross-sectional preparation of small particles with a core-shell structure; d) In the case that the particle surface is sensitive to electron beam, protect the particle surface from damage by electron beam irradiation; e) neutralization of the charge of the sample under electron irradiation to prevent powder splashing or dispersion due to charge repulsion; f) When the volume of X-rays generated is larger than the powder particles, the interpretation of qualitative and quantitative analysis results: In the case of analyzing the elemental composition of powders, sample preparation can also affect the analytical results because of coarseness in particle aggregates or agglomerates Degree, void space can affect X-ray intensity: To overcome these difficulties, it is important to standardize sample preparation for particle analysis: Microbeam Analysis for Spectroscopy and Energy Spectroscopy Powder sample preparation method

1 Scope

This document specifies the use of an energy dispersive spectrometer (EDS) or spectrometer mounted on an electron probe (EPMA) or scanning electron microscope (SEM): (WDS) Method of sample preparation when analyzing particles in powders: According to the purpose of analysis and particle size, the preparation method of powder particle samples classified: This document applies to inorganic particles with a particle size ranging from 100 nm to 100 μm: This document is not suitable for some special applications, such as forensic analysis or trace analysis:

2 Normative references

There are no normative references in this document:

3 Terms and Definitions

There are no terms and definitions that need to be defined in this document:

4 Abbreviations

The following abbreviations apply to this document: EDS: energy spectrometer (energy-dispersiveX-rayspectrometer) EDX: energy-dispersiveX-rayspectroscopy Energy-dispersiveX-rayspectrometry EPMA: Electron Probe Microanalysis Electron probe microanalyzer (electronprobemicroanalyzer) SEM: Scanning Electron Microscopy Scanning Electron Microscope WDS: Spectrometer (wavelength-dispersiveX-rayspectrometer) WDX: Wavelength-dispersiveX-rayspectroscopy Wavelength-dispersiveX-rayspectrometry 5: Sample preparation method 5:1 Overview Particle analysis mainly adopts the following sample preparation methods (see Figure 1): The specific steps of the preparation method are shown in 5:2: In some cases, no The use of other more suitable sample preparation methods for particle analysis is excluded:

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 41074-2021_English be delivered?

Answer: Upon your order, we will start to translate GB/T 41074-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 41074-2021_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 41074-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.