| US$909.00 · In stockDelivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email.
 GB/T 39559.3-2020: Specifications for operational monitoring of urban rail transit facilities - Part 3: Tunnel
 Status: Valid
 
	
		
			| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |  
			| GB/T 39559.3-2020 | English | 909 | Add to Cart | 6 days [Need to translate] | Specifications for operational monitoring of urban rail transit facilities - Part 3: Tunnel | Valid | GB/T 39559.3-2020 |  
	 
       PDF similar to GB/T 39559.3-2020 
 Basic data             | Standard ID | GB/T 39559.3-2020 (GB/T39559.3-2020) |           | Description (Translated English) | Specifications for operational monitoring of urban rail transit facilities - Part 3: Tunnel |           | Sector / Industry | National Standard (Recommended) |           | Classification of Chinese Standard | P51 |           | Classification of International Standard | 03.220.30 |           | Word Count Estimation | 49,496 |           | Date of Issue | 2020-12-14 |           | Date of Implementation | 2021-07-01 |           | Quoted Standard | GB/T 39559.1-2020; GB 50157; GB/T 50299; GB/T 50308; GB/T 50344; GB 50911; JGJ 8; JGJ/T 23; CJJ/T 202 |           | Regulation (derived from) | National Standard Announcement No. 28 of 2020 |           | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |           | Summary | This standard specifies the basic requirements, inspection, monitoring and condition assessment requirements and methods for the operation and monitoring technology of urban rail transit tunnel facilities. This standard is applicable to the operation inspection, monitoring and status evaluation of urban rail transit tunnel facilities. | GB/T 39559.3-2020: Specifications for operational monitoring of urban rail transit facilities - Part 3: Tunnel---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
 (Technical Specification for Operation and Monitoring of Urban Rail Transit Facilities Part 3: Tunnel)
ICS 03:220:30
P51
National Standards of People's Republic of China
Technical specifications for operation and monitoring of urban rail transit facilities
Part 3: Tunnel
Part 3:Tunnel
2020-12-14 release
2021-07-01 implementation
State Administration for Market Regulation
Issued by the National Standardization Management Committee
 Table of contentsForeword Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
4 Basic requirements 2
5 Check 2
5:1 Daily inspection 2
5:2 Periodic inspection 2
5:3 Special inspection 3
6 Monitoring 4
6:1 General requirements 4
6:2 Routine monitoring 6
6:3 Special monitoring 7
7 Status evaluation 8
7:1 General requirements 8
7:2 Evaluation of technical status 8
7:3 Structural safety evaluation 9
7:4 Evaluation of driving impact 10
Appendix A (Normative Appendix) Daily Tunnel Inspection Content 11
Appendix B (informative appendix) Sample of daily tunnel inspection record sheet 15
Appendix C (Normative Appendix) Periodic inspection contents of various tunnels 17
Appendix D (informative appendix) Sample of regular (special) tunnel inspection records 21
Appendix E (Normative Appendix) Tunnel Special Inspection Content 26
Appendix F (Informative Appendix) Sample Tunnel Deformation Monitoring Report 28
Appendix G (Normative Appendix) Sub-scale values of various tunnel technology conditions 30
Appendix H (Informative Appendix) Sample of Evaluation Form for Tunnel Technology Condition 45
References 46ForewordGB/T 39559 "Urban Rail Transit Facilities Operation Monitoring Technical Specifications" is divided into four parts:
---Part 1: General Provisions;
---Part 2: Bridge;
---Part 3: Tunnel;
---Part 4: Track and roadbed:
This part is Part 3 of GB/T 39559:
This section was drafted in accordance with the rules given in GB/T 1:1-2009:
This part was proposed by the Ministry of Transport of the People's Republic of China:
This part is under the jurisdiction of the National Urban Passenger Transport Standardization Technical Committee (SAC/TC529):
Drafting organizations of this section: Beijing Municipal Commission of Communications, Beijing Urban Construction Survey and Design Institute Co:, Ltd:, Scientific Research Institute of the Ministry of Transport
Research Institute, Beijing Urban Construction Design and Development Group Co:, Ltd:, Beijing Subway Operation Co:, Ltd:, Beijing Jinggang Subway Company, Chongqing Rail
Transportation (Group) Co:, Ltd:, Beijing Rail Transit Construction Management Co:, Ltd:, Beijing Urban Express Rail Construction Management Co:, Ltd:, Beijing Road
Railway Engineering Quality Supervision Station, China Academy of Railway Sciences Group Co:, Ltd:, Beijing Jiaotong University, Shanghai Survey and Design Institute (Group)
Co:, Ltd:, Beijing Rail Transit Design and Research Institute Co:, Ltd:, China Metallurgical Construction Research Institute Co:, Ltd:, Guangzhou Metro Group Co:, Ltd:, South
Nanjing Rail Transit Group Co:, Ltd:, Ningbo Rail Transit Group Co:, Ltd:, Xi'an Rail Transit Group Co:, Ltd:, Zhengzhou Metro
Group Co:, Ltd: operating branch, China Academy of Building Research Co:, Ltd:, Beijing Construction Engineering Quality Third Inspection Institute Co:, Ltd:
Company, Beijing Huan’an Engineering Inspection Co:, Ltd:, Beijing Zhongtian Lutong Engineering Survey Co:, Ltd:
The main drafters of this section: Zhang Jianquan, Ma Haizhi, Wang Chunqiang, Sun Zhuangzhi, Wang Sikai, Zhang Wei, Qiu Ronghua, Feng Xujie, Jin Huai, Ren Qian,
Tan Lei, Li Yujie, Shu Junjie, Yu Yang, Wang Ning, Ma Ruiqiao, Zhang Yuelong, Huang Zhonghui, Lu Weidong, Guo Chunsheng, He Meide, Kong Xiangli, Jia Yonggang,
Guo Xiaohua, Ma Weibin, Hao Zhihong, Qin Qinghua, Wang Gang, Xu Jinsong, Gao Hongwei, Zhu Shiyou, Xu Dawei, Xie Yuyu, Zhang Yue, Ma Xuemei, Ma Chaofeng,
Gao Ailin, Xu Xueliang, Liu Fei, Liu Stillkui, Cao Baoning, Yan Yulei, Gong Jieying, Yao Aimin, Li Fangning, Feng Shaopan, Yang Yuanxin:
Technical specifications for operation and monitoring of urban rail transit facilities
Part 3: Tunnel1 ScopeThis part of GB/T 39559 specifies the basic requirements, inspection, monitoring and status of the operation monitoring technology of urban rail transit tunnel facilities
Evaluation requirements and methods:
This part is applicable to the operation inspection, monitoring and status evaluation of urban rail transit tunnel facilities:2 Normative referencesThe following documents are indispensable for the application of this document: For dated reference documents, only the dated version applies to this article
Pieces: For undated references, the latest version (including all amendments) applies to this document:
GB/T 39559:1-2020 Technical Specification for Operation Monitoring of Urban Rail Transit Facilities Part 1: General Provisions
GB 50157 Metro Design Code
GB/T 50299 Construction Quality Acceptance Standard for Underground Railway Engineering
GB/T 50308 Urban Rail Transit Engineering Survey Specification
GB/T 50344 Technical standard for building structure inspection
GB 50911 Technical Code for Urban Rail Transit Engineering Monitoring
JGJ8 Building Deformation Measurement Code
JGJ/T 23 Technical specification for testing concrete compressive strength by rebound method
CJJ/T 202 Technical Specification for Safety Protection of Urban Rail Transit Structure3 Terms and definitionsThe following terms and definitions defined in GB/T 39559:1-2020 apply to this document:
3:1
Tunnel
Underground structures that provide space for driving, including open-cut, mining, shield and immersed tunnels and related auxiliary facilities:
Note: Rewrite GB/T 50833-2012, term 7:3:1:
3:2
Routine monitoring
In order to fully grasp the changes of the operating tunnel structure, the tunnel structure deformation monitoring work was carried out during the entire life cycle of the tunnel:
3:3
Special monitoring specialmonitoring
In order to grasp the changes in the damaged section of the tunnel structure and the section of the tunnel structure affected by the protection zone project, the tunnel structure will be carried out within a certain period:
Structural deformation monitoring work:
3:4
Technical status evaluation technicalstatusevaluation
Based on the results of tunnel operation inspection and monitoring, an evaluation of the disease condition of the tunnel is made:
 
 Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 39559.3-2020_English be delivered?Answer: Upon your order, we will start to translate GB/T 39559.3-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 39559.3-2020_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 39559.3-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries Question 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected] . In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.    |