HOME   Cart(6)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 35691-2017 English PDF

US$759.00 · In stock
Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 35691-2017: Guide for photovoltaic power station identification system
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 35691-2017English759 Add to Cart 6 days [Need to translate] Guide for photovoltaic power station identification system Valid GB/T 35691-2017

PDF similar to GB/T 35691-2017


Standard similar to GB/T 35691-2017

GB 36893   GB 35971   GB/T 35073   GB/T 45573   GB/T 45483   

Basic data

Standard ID GB/T 35691-2017 (GB/T35691-2017)
Description (Translated English) Guide for photovoltaic power station identification system
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard F04
Classification of International Standard 27.160
Word Count Estimation 38,319
Date of Issue 2017-12-29
Date of Implementation 2018-07-01
Regulation (derived from) National Standards Bulletin 2017 No. 32
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

GB/T 35691-2017: Guide for photovoltaic power station identification system

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Guide for photovoltaic power station identification system ICS 27.160 F04 National Standards of People's Republic of China Photovoltaic Power Station Identification System Coding Guidelines 2017-12-29 Posted 2018-07-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 basic requirements 2 5 craft related logo 3 5.1 logo structure 3 5.2 encoding character type 3 5.3 prefix 3 5.4 station code 3 5.5 System Code 4 5.6 device code 4 5.7 Part Number 4 5.8 Each system and major equipment identification 4 6 installation point identification 5 6.1 logo structure 5 6.2 encoding character type 5 6.3 prefix 5 6.4 station code 5 6.5 Install the unit code 5 6.6 Delimiter 6 6.7 installation space code 6 7 location identification 6 7.1 logo structure 6 7.2 Code character type 6 7.3 prefix 6 7.4 station code 6 7.5 building (structure) building code 7 7.6 Room (Partition) Code 7 8 Marking provisions 7 8.1 Note format 7 8.2 Drawings 8 8.3 Live Marking 8 Appendix A (Normative) System Index 9 Appendix B (Normative) Device Index 13 Appendix C (Normative) Component Index 15 Appendix D (Normative) Building (Structure) Index 17 Appendix E (Normative) Process-related labeling of systems and major equipment 18

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some of this document may be patentable. The issuing agencies of this document do not bear the responsibility of identifying these patents. This standard proposed by the China Electricity Council and centralized. This standard was drafted unit. Shanghai Electric Power New Energy Development Co., Ltd., Yellow River upstream hydropower development limited liability company, Guangzhou Jianxin Technology Co., Ltd. The main drafters of this standard. Zhou Yao, Yu Jian, Wang Xingyu, Zhang Wanjun, Xu Lixia, Kim Dong-bing, Xie Li Li, Shen Haiou, Tang Lin, Zou Jian, Xu Jun, Shi Bangwen, Liu Yong, Lu Yuanming, Zhao Hui, Fu Guoxuan, Bai Yu, Chen Wei. Photovoltaic Power Station Identification System Coding Guidelines

1 Scope

This standard specifies the basic requirements of photovoltaic power station identification system coding, process-related identification, installation point identification, location identification and standard Note requirements. This standard applies to photovoltaic power plants and photovoltaic power generation system design, construction and operation and maintenance.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 50549 Power Plant Identification System coding standards GB 50797 photovoltaic power station design specifications GB/T 51061 code for grid project coding system code

3 Terms and definitions

GB 50797 and GB/T 50549 define the following terms and definitions apply to this document. For ease of use, repeat the column below Some of GB 50797 and GB/T 50549 out of some of the terms and definitions. 3.1 Photovoltaic module photovoltaicmodule With the package and the internal connection, can provide a separate DC output, the smallest indivisible solar cell assembly. Also known as the sun Battery components. [GB 50797-2012, Definition 2.1.1] 3.2 PV module string photovoltaicmodulesstring In photovoltaic power generation system, a number of photovoltaic modules in series, the formation of a certain DC output circuit unit. [GB 50797-2012, Definition 2.1.2] 3.3 Photovoltaic power unit photovoltaicpowerunit Photovoltaic power plants, with a certain number of PV modules string, through the DC confluence box collection, the inverter by the centralized inverter (or through the string Inverter inverter, the exchange of confluence box collection) and isolation step-up transformer boost to meet the grid frequency and voltage requirements of the power supply. Also known as single Yuan power generation module. Note rewrite GB 50797-2012, the definition of 2.1.3. 3.4 Photovoltaic square photovoltaicarray A number of photovoltaic modules in a mechanical and electrical manner assembled together and have a fixed support structure and constitute the DC Electrical unit. Also known as photovoltaic array. [GB 50797-2012, Definition 2.1.4]

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 35691-2017_English be delivered?

Answer: Upon your order, we will start to translate GB/T 35691-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 35691-2017_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 35691-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.