US$259.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 34939.1-2017: D.C. ±800 kV composite post insulator -- Part 1: Composite post insulator with resin impregnated glass fibers solid core Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 34939.1-2017 | English | 259 |
Add to Cart
|
3 days [Need to translate]
|
D.C. ±800 kV composite post insulator -- Part 1: Composite post insulator with resin impregnated glass fibers solid core
| Valid |
GB/T 34939.1-2017
|
PDF similar to GB/T 34939.1-2017
Basic data | Standard ID | GB/T 34939.1-2017 (GB/T34939.1-2017) | | Description (Translated English) | D.C. ��800 kV composite post insulator -- Part 1: Composite post insulator with resin impregnated glass fibers solid core | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K48 | | Classification of International Standard | 29.080.10 | | Word Count Estimation | 13,198 | | Date of Issue | 2017-11-01 | | Date of Implementation | 2018-05-01 | | Regulation (derived from) | National Standard Announcement 2017 No. 29 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
GB/T 34939.1-2017: D.C. ±800 kV composite post insulator -- Part 1: Composite post insulator with resin impregnated glass fibers solid core ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
DC ± 800 kV composite post insulator-Part 1. Composite post insulator with resin impregnated glass fibers solid core
ICS 29.080.10
K48
National Standards of People's Republic of China
± 800kV DC post composite insulators
Part 1. Solid epoxy glass fiber core
Composite insulators
DC ± 800kVcompositepostinsulator-
Part 1.Compositepostinsulatorwithresinimpregnatedglassfiberssolidcore
Posted.2017-11-01
2018-05-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
China National Standardization Administration released
Directory
Foreword Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions 2
4 logo 2
5 environmental conditions 2
6 Transport, storage and installation information 2
7 Features 2
7.1 Electrical Characteristics 2
7.2 Mechanical Characteristics 2
7.3 Size Features 3
7.4 Other 4
8 test classification 4
9 Design Test 4
9.1 General 4
9.2 Interface and end fitting connection zone test 4
9.3 Assembled core load test 4
9.4 Umbrella and umbrella cover material test 4
9.5 core material test 6
10 type test 6
10.1 type test test sample 6
10.2 size check 6
10.3 Electrical test 6
10.4 Mechanical test 7
11 sample test 8
11.1 General 8
11.2 Size check (E1 E2) 8
11.3 Sheath Thickness Inspection (E1 E2) 9
11.4 Galvanized layer test (E1 E2) 9
11.5 Steep wave front shock test (E1) 9
11.6 Measurement of surface temperature rise under power frequency voltage (E1) 9
11.7 Provisions for mechanical load verification (E1) 9
12 one by one experiment 9
12.1 inscription of insulators
12.2 Visual inspection 9
12.3 Tensile load test 9
12.4 core material test 9
Foreword
GB/T 34939 "± 800kV DC post composite insulators" is divided into two parts.
--- Part 1. Epoxy glass fiber solid core composite insulators;
--- Part 2. Ceramic core composite insulators.
This section GB/T 34939 Part 1.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This part is proposed and managed by China Electrical Equipment Industry Association.
This section drafted unit. Xi'an High Voltage Apparatus Research Institute Co., Ltd., China Southern Power Grid Corporation Technology Research Center, Machinery Industry Beijing
Electrician Institute of Economic and Technological, Nantong God horse power technology companies, Tsinghua University, State Grid Electric Power Research Institute, Xi'an West high-voltage casing with
Limited liability company, Tangshan high-voltage porcelain Co., Ltd., Suzhou Electric Porcelain Co., Ltd.
Yao Junrui, Lu Jinzhuang, Fang Xiaoyan, Ma Bin, Li Xiaolin, Dang Zhenping, Luo Bing, Liang Xidong, Wu Guangya, Zhao Yuming, Zhang Rui,
Chen Ziyan, Yang Ming, Lu Zhou, Zhao Linjie, Zhao Hui.
± 800kV DC post composite insulators
Part 1. Solid epoxy glass fiber core
Composite insulators
1 Scope
GB/T 34939 provisions of this section ± 800kV DC epoxy fiberglass solid core column composite insulator (hereinafter referred to as
Edge) definition, characteristics, test classification, test methods and judgments.
This section applies to ± 800kV DC converter station power equipment and devices with solid pillar composite insulators.
Note. The insulators mainly bear bending, twisting load. Insulators may also be subject to tensile or compressive loads in some special cases.
This section does not apply to the switchgear insulator, nor is it suitable for epoxy glass fiber hollow core pillars composite insulators.
This section does not include the selection of insulators under special operating conditions.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 311.1 insulation coordination Part 1. Definitions, principles and rules
Rubber, vulcanized or thermoplastic - Determination of tensile stress - strain properties
GB/T 529 Determination of tear strength of vulcanized rubber or thermoplastic rubber (pant-shaped, rectangular and crescent-shaped specimen)
GB/T 1408.1 Insulating material Electrical strength test methods Part 1
GB/T 1408.2 Insulating material electrical strength test methods Part 2. Additional requirements for the application of DC voltage test
Rubber, vulcanized, Determination of insulation resistance
GB/T 2900.8 Electrotechnical terminology insulators
GB/T 6553 Electrical insulating materials for use in harsh environmental conditions - Test methods for resistance to tracking and erosion
GB/T 8287.1-2008 Indoor and outdoor post insulators for nominal voltages above 1000V Part 1. Porcelain or glass
Insulator test
GB/T 8287.2-2008 Indoor and outdoor post insulators for nominal voltages above 1000V Part 2. Dimensions and
characteristic
GB/T 11344 nondestructive testing contact ultrasonic pulse echo thickness measurement method
GB/T 22079 Nominal voltage higher than 1000V Use of indoor and outdoor polymer insulators General definitions, test methods and receiving
Guidelines
GB/T 24622 insulator surface wettability measurement guidelines
GB/T 24623 high voltage insulator radio interference test
GB/T 25096-2010 AC voltage is higher than 1000V Substations substation pillar composite insulator definition, test methods and access
Admission criteria
GB/T 26218.1 Pollution conditions used in the selection of high voltage insulators and size determination Part 1. Definitions, information and general
in principle
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 34939.1-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 34939.1-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 34939.1-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 34939.1-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|