HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (1 Nov 2025)

GB/T 32901-2016 English PDF

US$499.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 32901-2016: General specification for protection relay in smart substation
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 32901-2016English499 Add to Cart 4 days [Need to translate] General specification for protection relay in smart substation Valid GB/T 32901-2016

PDF similar to GB/T 32901-2016


Standard similar to GB/T 32901-2016

GB/T 38953   GB/T 37155.2   GB/T 19826   GB/T 32898   GB/T 32897   

Basic data

Standard ID GB/T 32901-2016 (GB/T32901-2016)
Description (Translated English) General specification for protection relay in smart substation
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K45
Classification of International Standard 29.240
Word Count Estimation 25,276
Date of Issue 2016-08-29
Date of Implementation 2017-03-01
Regulation (derived from) National Standard Announcement 2016 No.14
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

GB/T 32901-2016: General specification for protection relay in smart substation

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
General specification for protection relay in smart substation ICS 29.240 K45 National Standards of People's Republic of China General technical conditions for relay protection of intelligent substations 2016-08-29 released 2017-03-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Management Committee released Directory Preface III 1 Scope 1 2 normative reference document 1 3 Terms and definitions 2 4 technical requirements 2 5 Test Method 10

6 inspection rules

Marking, packaging, transportation and storage 8 other 15 Appendix A (informative) Network stress test program 16 Appendix B (Normative Appendix) Protection Device Message Frame Format 19 Appendix C (Normative Appendix) Equipment Communication Interface Test 20

Foreword

This standard is drafted in accordance with the rules given in GB/T 1.1-2009. This standard is proposed by the China Electricity Council and centralized. Please note that some of the contents of this document may involve patents. The issuer of this document does not assume responsibility for the identification of these patents. The drafting of the standard unit. Nanjing Nairui following Electric Co., Ltd., Zhejiang Electric Power Dispatching Control Center, the State Electric Power Dispatching Control Center, China Southern Power Grid Power Dispatching Control Center, Fujian Electric Power Research Institute, Guangdong Power Grid Corporation, Jiangsu Electric Power Research Institute, Guangzhou Power Supply Bureau, Zhejiang Electric Power Research Institute, China Electric Power Research Institute, Shanghai Electric Power Design Institute, Guodian Nanjing Automation Co., Ltd., Beijing Quartet Jubao Automation Co., Ltd., XJ Electric Co., Ltd. The main drafters of this standard are. Lu Hang, Qiu Youtao, Li Li, Wang Delin, Xu Peng, Zhu Weijun, Li Yiquan, Yuan Yubo, Xu Qiangchao, Wang Song, Qian Guoming, Liao Zeyou, Jiang Jianning, Li Chaoqun, Ling Gang, Cheng Xiao, Wu Jun, Xiao Yuanqing, Li Peng, Deng Chaoping, Du Zhenhua. General technical conditions for relay protection of intelligent substations

1 Scope

This standard specifies the intelligent substation line protection, circuit breaker protection, short lead protection, bus protection, transformer protection, high voltage parallel power (Hereinafter referred to as the protection device) and related equipment, technical requirements, test methods, inspection rules, the protection of equipment, As well as requirements for labeling, packaging, transportation and storage. This standard applies to the intelligent substation 110 (66) kV ~ 750kV voltage level protection device, is the device development, design, manufacture, test, Inspection and application of the basis. For the relay protection device input and output interface form and requirements, this standard only provides when the relay protection device using SV or GOOSE when the relevant digital interface requirements, does not specify the intelligent substation relay protection device input and output interface form. Intelligent substation 35kV and below the voltage level of the protection device can refer to the implementation of this standard.

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. GB/T 191 Packaging and Storage Icons (GB/T 191-2008, ISO 780..1997, MOD) General specification for computer premises GB/T 2887-2011 GB/T 4798.2 Environmental conditions for the application of electrical and electronic products - Part 2. Transport (GB/T 4798.2-2008, IEC 60721-3- 2..1997, MOD) Basic test methods for relay protection and safety automatic devices GB/T 7261-2008 GB/T 9361-2001 Computing station site safety requirements GB/T 11287 Electrical relays - Part 21. Vibration, shock, impact and seismic tests for measuring relays and protective devices Part 1. Vibration test (sinusoidal) (GB/T 11287-2000, IEC 60255-21-1. 1988, IDT) General specification for packaging of electromechanical products GB/T 13384 Technical specification for relay protection and safety automatic device GB/T 14285 GB/T 14537-1993 Impact and impact tests for relays and protective devices (IEC 60255-21-2. 1988, IDT) GB/T 14598.27 Measuring relays and protective devices - Part 27. Product safety requirements (GB/T 14598.27-2008, IEC 60255-27..2005, MOD) GB/T 15145 General technical conditions for transmission line protection devices GB/T 19520.12 Mechanical construction of electronic equipment 482.6mm (19in) series Mechanical structure dimensions Part 3-101. Boxes And its plug-in (GB/T 19520.12-2009, IEC 60297-3-101..2004, IDT) GB/T 20840.8 Transformers - Part 8. Electronic current transformers (GB/T 20840.8-2007, IEC 60044-8. 2002, MOD) Technical guide for intelligent substation GB/T 30155-2013 General specification for relay protection and safety automatic devices General specification for DL/T 670 busbar protection devices General specification for DL/T 770 transformer protection device DL/T 860 (all parts) substation communication networks and systems

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 32901-2016_English be delivered?

Answer: Upon your order, we will start to translate GB/T 32901-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 32901-2016_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 32901-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information