GB/T 3286.3-2012: Methods for chemical analysis of limestone and dolomite -- Part 3: The determination of aluminium oxide content -- The chrome azurol S spectrophotometric method and the complexometric titration method
Status: Valid

GB/T 3286.3: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 3286.3-2012English349 Add to Cart 3 days [Need to translate] Methods for chemical analysis of limestone and dolomite -- Part 3: The determination of aluminium oxide content -- The chrome azurol S spectrophotometric method and the complexometric titration method Valid GB/T 3286.3-2012
GB/T 3286.3-1998English279 Add to Cart 3 days [Need to translate] Methods for chemical analysis of limestone and dolomite--The determination of aluminium oxide content Obsolete GB/T 3286.3-1998
GB/T 3286.3-1982EnglishRFQ ASK 3 days [Need to translate] Chemical analysis of limestone and dolomite--The perchloric acid dehydration gravimetric method for determination of silicon dioxide Obsolete GB/T 3286.3-1982

PDF similar to GB/T 3286.3-2012


Standard similar to GB/T 3286.3-2012

GB/T 3286.11   GB/T 3286.8   GB/T 3286.9   GB/T 3286.12   GB/T 3286.10   GB/T 3286.6   

Basic data

Standard ID GB/T 3286.3-2012 (GB/T3286.3-2012)
Description (Translated English) Methods for chemical analysis of limestone and dolomite -- Part 3: The determination of aluminium oxide content -- The chrome azurol S spectrophotometric method and the complexometric titration method
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard D52
Classification of International Standard 73.080
Word Count Estimation 15,140
Older Standard (superseded by this standard) GB/T 3286.3-1998
Quoted Standard GB/T 2007.2; GB/T 3286.1; GB/T 3286.2; GB/T 3286.4; GB/T 6379.2; GB/T 6682; GB/T 8170
Regulation (derived from) National Standards Bulletin 2012 No. 28
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the use Chromazurol S spectrophotometry and complexometric titration alumina content. This section applies to limestone, dolomite alumina content, but also for metallurgical lime alumina content. Chromazurol S spectrophotometry, me

GB/T 3286.3-2012: Methods for chemical analysis of limestone and dolomite -- Part 3: The determination of aluminium oxide content -- The chrome azurol S spectrophotometric method and the complexometric titration method



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS73.080 D52 National Standards of People's Republic of China Replacing GB/T 3286.3-1998 Methods for chemical analysis of limestone and dolomite Part 3. Determination of alumina content Chromium Azure S Spectrophotometry and Complexometry Part 3. Thedeterminationofaluminiumoxidecontent-Thechrome Issued on. 2013-05-01 2012-11-05 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

GB/T 3286 "Methods for chemical analysis of limestone and dolomite" is divided into nine sections. --- Part 1. calcium oxide and magnesium oxide content complexometric titration and flame atomic absorption spectrometry; --- Part 2. Determination of silica content of silicon molybdenum blue spectrophotometric method and perchloric acid dehydration gravimetric method; --- Part 3. Determination of alumina content of chromium azure S spectrophotometric and complexometric titration; --- Part 4. Determination of iron oxide content of phenanthroline spectrophotometric method and the flame atomic absorption spectrometry; --- Part 5. Determination of manganese oxide content; --- Part 6. Determination of phosphorus content; --- Part 7. Determination of sulfur content; --- Part 8. Determination of loss on ignition; --- Part 9. Determination of the amount of carbon dioxide. This is Part 3 GB/T 3286's. Rules in this section in accordance with GB/T 1.1-2009 given draft. This Part replaces GB/T 3286.3-1998 "limestone, dolomite chemical analysis of aluminum oxide content determination." This section compared with the GB/T 3286.3-1998, mainly for the following changes. --- This part of the standard name to "Methods for chemical analysis of limestone and dolomite - Part 3. Determination of aluminum oxide content of chromium Azure S spectrophotometric and complexometric titration "; --- Normative references canceled the reference standard reign, and adds some reference standards; --- Carried out jointly between laboratory precision test statistics obtained by the repeatability limit (r) and reproducibility limit R instead of "allowable difference"; --- Change the part of the text expression. This part is proposed by the China Iron and Steel Association. This part of the National Steel Standardization Technical Committee (SAC/TC183) centralized. This section is drafted. Wuhan Iron and Steel (Group) Corporation, Wuhan University of Science and Technology, Metallurgical Industry Information Standards Institute. The main drafters of this section. Wen east, Chen Shihua, Shao Mei, Zhang Suizhong, Zhou Zheng, CAO Hong-yan, Yu Weihua, Xu Jianping, Chou Jinhui, Gao Jianping. This part of the standard replaces the previous editions are. --- GB/T 3286.3-1988; --- GB/T 3286.5-1982; --- GB/T 3286.6-1992. Methods for chemical analysis of limestone and dolomite Part 3. Determination of alumina content Chromium Azure S Spectrophotometry and Complexometry

1 Scope

This section GB/T 3286 requirements using Chromium Azure S Spectrophotometry and complex titration alumina content. This section applies to limestone and dolomite - The determination of aluminum oxide content, is also applicable to the determination of the metallurgical alumina content of lime. CHROME Green S spectrophotometric measurement range. alumina content (mass fraction) from 0.01% to 0.75%; complexometric titration, measurement range. Alumina Content (mass fraction) is greater than 0.5%.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated edition applies to this article Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 2007.2 bulk minerals sampling and sample preparation General manual sample preparation method GB /Part 1 T3286.1 limestone and dolomite Chemical analysis methods. Determination of calcium oxide and magnesium oxide content of the complex drops Titration and flame atomic absorption spectrometry GB/T 3286.2 limestone and dolomite chemical analysis - Part 2. Determination of silicon dioxide content of silicon-molybdenum blue spectrophotometric Degree method and perchloric acid dehydration gravimetric method GB/T 3286.4 limestone and dolomite Chemical analysis methods - Part 4. Determination of iron oxide content of phenanthroline spectrophotometric Method and the flame atomic absorption spectrometry GB/T 6379.2 measurement methods and results of Accuracy (trueness and precision) - Part 2. Determine the standard measurement method to repeat Of the basic methods of reproduction Laboratory use specifications and test methods GB/T 6682 Analysis GB/T 8170 represents rounding off rules and limit values \u200b\u200band judgment

3 Chromium Azure S Spectrophotometry

3.1 Principle Sample with sodium carbonate - boric acid flux melt, dilute hydrochloric acid leaching aliquot of the test solution, zinc -EDTA masking iron and manganese ions to. Hexamethylenetetramine buffer solution at pH 5.7, aluminum and chrome azure S generated purple complex wavelength spectrophotometer Absorbance was measured at 545nm. Interference titanium can be added to eliminate the hydrogen peroxide solution. 3.2 Reagents Analysis Unless otherwise stated, use only reagents of recognized analytical grade and in line with GB/T 6682 provisions for more than three or pure distilled water Considerable degree water. 3.2.1 mixed flux. Take two anhydrous sodium carbonate and a boric acid grind, and mix. 3.2.2 hydrochloric acid (15).