   US$879.00 ยท In stock Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 32710.6-2016: Safety requirements for environmental testing and conditioning equipment -- Part 6: Climatic chambers for biological application Status: Valid    
      
    
  
	
		
			| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF | 
		 
			| GB/T 32710.6-2016 | English | 879 | 
   Add to Cart
   | 
                    7 days [Need to translate]
                 | 
                    Safety requirements for environmental testing and conditioning equipment -- Part 6: Climatic chambers for biological application
                 | Valid | 
                    GB/T 32710.6-2016
                 | 
		 
	 
     
     
  
	 
       PDF similar to GB/T 32710.6-2016 
    
   
    
     
          
  
  
    
  Basic data             |  Standard ID  |          GB/T 32710.6-2016 (GB/T32710.6-2016) |               |  Description (Translated English)  |          Safety requirements for environmental testing and conditioning equipment -- Part 6: Climatic chambers for biological application |               |  Sector / Industry  |          National Standard (Recommended) |               |  Classification of Chinese Standard  |          N61 |               |  Classification of International Standard  |          19.040 |               |  Word Count Estimation  |          44,411 |               |  Date of Issue  |          2016-06-14 |               |  Date of Implementation  |          2017-01-01 |               |  Quoted Standard  |          GB 4208-2008; GB 4706.1-2005; GB 4706.13-2014; GB 4706.17-2010; GB 4706.71-2008; GB 4706.89-2008; GB 4793.1-2007; GB 4943.1-2011; GB/T 5465.2-2008; GB 7000.1-2007; GB/T 32710.1-2016; ISO 7000-2004; ISO 7010-2011; ISO 61770-2008 |               |  Regulation (derived from)  |          National Standard Announcement No. 8 of 2016 |               |  Issuing agency(ies)  |          General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |               |  Summary  |          This standard specifies the biological artificial climate chamber for measurement, control and laboratory use, the seed germination test box, the light incubator, the irradiation test chamber, the constant temperature and humidity incubator, the mold incubator, the comprehensive drug stability test box, (Including lasers, sound pressure and ultrasonic pressure), released gases, explosions and/or explosions, as well as the effects of electrical shock and electrical burns on the light stability chamber, mechanical hazards, flame spread from inside and outside the device, overheating, fluid and fluid pressure Implosion and the safety of biological and chemical hazards. (EMC) requirements, protective measures against explosive atmospheres, repairs (repairs), and maintenance (repairs) of persons who do not include the reliability, performance, or other characteristics of the non-safety-related equipment, the effectiveness of the shipping package. Headquarters |         
  GB/T 32710.6-2016: Safety requirements for environmental testing and conditioning equipment -- Part 6: Climatic chambers for biological application ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.  
Safety requirements for environmental testing and conditioning equipment.Part 6. Climatic chambers for biological application
ICS 19.040
N61
National Standards of People's Republic of China
Environmental testing equipment and equipment safety regulations
Part 6. Biological artificial climate chamber
Part 6. Climaticchambersforbiologicalapplication
2016-06-14 release
2017-01-01 Implementation
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
China National Standardization Management Committee released
Directory
Preface III
1 Scope 1
2 normative reference document 1
3 Terms and definitions 2
4 Test 6
5 logo and document 11
6 anti-shock 22
7 Mechanical hazards 25
8 Resistance to mechanical shock and impact
9 to prevent the spread of flame 27
10 Equipment temperature limits and heat resistance 27
11 Risk of fluid protection
12 Radiation protection (including laser source), sound pressure and ultrasonic pressure 33
13 Protection against release of gases, explosions and implosion
14 components 35
Protection of interlocking equipment
Test and Measurement Equipment
Appendix 39
Reference 40
Foreword
GB/T 32710 based on GB/T 32710.1-2016 "Environmental testing equipment and equipment safety regulations Part 1. General"
GB 4793.1-2007 "Safety requirements for electrical equipment for measurement, control and laboratory use Part 1. General requirements"
To develop.
GB/T 32710 "Environmental testing equipment and equipment safety regulations" is divided into 13 parts.
- Part 1. General;
- Part 2. cryogenic temperature cycling devices;
- Part 3. low temperature thermostat bath;
- Part 4. High temperature thermostatic circulation devices;
- Part 5. High temperature thermostat bath;
- Part 6. Biological artificial climate chamber;
- Part 7. Climate and Environmental Test Chamber;
- Part 8. Biochemical incubator;
- Part 9. Thermostat incubator;
Part 10. electric drying oven and electric blast drying oven;
- Part 11. Air heat aging test chamber;
- Part 12. Salt tank;
- Part 13. Oscillators, oscillating thermostat tanks and oscillating incubators.
This part is part 6 of GB/T 32710.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
GB/T 32710.6 should be used in conjunction with GB/T 32710.1-2016 and GB 4793.1-2007. This section states that "applicable"
, The corresponding strip of GB 4793.1-2007 shall be applied to this part; this section states that the words "substitute" or "modification"
The provisions of this section "increase" part, indicating that in addition to meet the corresponding provisions of GB 4793.1-2007, but also in line with the Department
Increase the number of points. In order to distinguish between GB 4793.1-2007, the number of the added section of this section begins at 101, for example 5.2.101,
aa), bb) and so on.
This part is made by the China Machinery Industry Federation.
This part of the National Laboratory Equipment and Equipment Standardization Technical Committee (SAC/TC526) centralized.
This part of the main drafting unit. Hangzhou snow in the temperature Technology Co., Ltd., Chongqing Galaxy Test Instrument Co., Ltd., Shanghai Esper
Environmental Equipment Co., Ltd., Machinery Industry Instrument Integrated Technology and Economic Research Institute, China Testing Technology Co., Ltd.
The main drafters of this part. Xu Yueming, Zhang Guiling, Wang Huabin, Cao Yankang, Mei Ke, Fang Xiaozhi, Liu Xiajing, Li Jiying.
Environmental testing equipment and equipment safety regulations
Part 6. Biological artificial climate chamber
1 Scope
GB/T 32710 this part of the provisions of the measurement, control and laboratory use of bio-artificial climate chamber, seed germination test chamber, light
According to the incubator, irradiation test chamber, constant temperature and humidity incubator, mold incubator, integrated drug stability test box, drug light stability test chamber
Electric shock and electric burns, mechanical hazards, flame spread out from inside the device, excessive temperature, fluid and fluid pressure effects, radiation effects (including laser
Sound pressure and ultrasonic pressure), release of gas, explosion and implosion, as well as biological and chemical hazards. But does not include nothing to do with safety
The reliability of the equipment, performance or other characteristics, the effectiveness of transport packaging, electromagnetic compatibility (EMC) requirements, the protection of the explosive environment,
Maintenance (repair), maintenance (repair) personnel protection.
Note 1. The working temperature range of the bio-artificial climate chamber can be lower and/or higher than the ambient temperature. As a cold source, it can be used from air and air
Heat is absorbed in the sample, and as heat source, heat can be applied to the air and to the sample in the air.
This part applies to the measurement, control and laboratory use of bio-artificial climate chamber, seed germination test box, light incubator, radiation test
Test box, constant temperature and humidity incubator, mold incubator, integrated drug stability test box, drug light stability test chamber.
Note 2. This type of instrument and equipment may be a probing chamber, or it may be a walk-in test chamber.
2 normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article
Pieces. For undated references, the latest edition (including all modifications) applies to this document.
GB 4208-2008 enclosure protection class (IP code)
Safety of household and similar electrical appliances - Part 1. General requirements GB 4706.1-2005
GB 4706.13-2014 Particular requirements for safety and refrigerating appliances for household and similar electrical appliances, ice cream machines and ice machines
GB 4706.17-2010 Safety of household and similar electrical appliances - Particular requirements for compressors
GB 4706.71-2008 Safety and water supply installations for household and similar electrical appliances - Particular requirements for fixed circulation pumps
GB 4706.89-2008 Safety of household and similar electrical appliances Industrial and commercial high pressure cleaners and steam cleaners
Claim
GB 4793.1-2007 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1. General requirements
Information technology - Equipment safety - Part 1. Generic requirements GB 4943.1-2011
Graphical symbols for use in electrical equipment - Part 2. Graphical symbols ISO /TS 545 Technical Corrigendum
Lamps - Part 1. General requirements and tests
Safety requirements for mechanical refrigeration systems for refrigeration and heating GB 9237-2001
Safety code for environmental testing equipment and equipment - Part 1. General principles GB/T 32710.1-2016
ISO 7000..2004 Graphical symbols for equipment and a list (Graphicalsymbolsforuseonequipment-
Indexandsynopsis)
ISO 7010..2011 Graphic symbols Safety colors and safety signs Registration Safety signs (Graphicalsymbols-Safety
coloursandsafetysigns-Registeredsafetysigns)
IEC 61770..2008 Electrical appliances connected to manifolds Avoiding anti-siphon and failure of hose assemblies (Electricappliances
connectedtothewatermains-Avoidanceofbacksiphonageandfailureofhose-sets
   
   
  
  
    
  Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 32710.6-2016_English be delivered?Answer: Upon your order, we will start to translate GB/T 32710.6-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 32710.6-2016_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 32710.6-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs):  List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to  [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.  
        
   
        
       
          
               
 
          |