GB/T 32704-2016: Safety requirements for laboratory instrument and equipment -- Balance instrument
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 32704-2016English379 Add to Cart 4 days [Need to translate] Safety requirements for laboratory instrument and equipment -- Balance instrument Valid GB/T 32704-2016

PDF similar to GB/T 32704-2016


Standard similar to GB/T 32704-2016

GB/T 30099   GB/T 29252   GB/T 10589   GB/T 32710.10   GB/T 32708   

Basic data

Standard ID GB/T 32704-2016 (GB/T32704-2016)
Description (Translated English) Safety requirements for laboratory instrument and equipment -- Balance instrument
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard N61
Classification of International Standard 17.060; 71.040.10
Word Count Estimation 19,132
Date of Issue 2016-06-14
Date of Implementation 2017-01-01
Quoted Standard GB 3101-1993; GB 4793.1-2007; GB/T 11021-2014
Regulation (derived from) National Standard Announcement No. 8 of 2016
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the general specification for the safety of the design and methods of laboratory balances for the operator and the surrounding environment. This standard is applicable to the design and manufacture of laboratory balance instruments (hereinafter referred to as "balance").

GB/T 32704-2016: Safety requirements for laboratory instrument and equipment -- Balance instrument


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Safety requirements for laboratory instrument and equipment.Balance instrument ICS 17.060; 71.040.10 N61 National Standards of People's Republic of China Laboratory equipment and equipment safety standard balance instrument 2016-06-14 release 2017-01-01 Implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Management Committee released Directory Preface I 1 Scope 1 2 normative reference document 1 3 Terms and definitions 1 4 Test 2 5 signs and documents 4 6 anti-shock 6 7 anti-mechanical hazards 12

8 Resistance to mechanical shock and impact

9 to prevent the spread of flame 12 10 balance temperature limits and heat resistance 12 11 components 14 Appendix A (Normative Appendix) Routine Tests 15

Foreword

This standard is drafted in accordance with the rules given in GB/T 1.1-2009. This standard is proposed by the China Machinery Industry Federation. This standard by the National Laboratory of Laboratory Equipment and Equipment Standardization (SAC/TC526) centralized. The main drafting of this standard. Shanghai Jingke Tianmei Scientific Instrument Co., Ltd., Changsha Xiangping Technology Development Co., Ltd., mechanical industry instrument Institute of Instrumentation Integrated Technology and Economy, Zhejiang Institute of Metrology and Testing Technology, China Instrument Industry Association Laboratory Instrument Branch, on Hai Liangping scientific instrumentation company, Shenyang Dragon Electronics Co., Ltd., Shanghai Precision Science Instrument Co., Ltd., Shanghai metering test technology Research Institute. The main drafters of this standard. Dong Li, Xiong Yifan, Zhang Guiling, Ge Rui, Wang Jia Long, Pan Ke Min, Zhang Zhi. Laboratory equipment and equipment safety standard balance instrument

1 Scope

This standard specifies the general specification for the safety and safety of instruments used in structural design and methods for operators and surroundings. This standard is applicable to the design and manufacture of laboratory balances instruments (hereinafter referred to as "balances").

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. GB 3101-1993 General principles of quantity, unit and symbol GB 4793.1-2007 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1. General requirements Electrical insulation - Heat resistance and presentation method GB/T 11021-2014

3 terms and definitions

GB 4793.1-2007 Definitions and the following terms and definitions apply to this document. 3.1 anti-shock protection equipment 3.1.1 Class I equipment class Ⅰequipment Use the following methods to obtain protection against electric shock equipment. --- the use of basic insulation; --- also equipped with a connection device, so that those in the basic insulation once the failure will bring dangerous voltage conductive parts and buildings The protective earth conductor in the wiring is connected. Note. Class I equipment can have double insulation and reinforced insulation parts. 3.1.2 Class II equipment class Ⅱequipment Anti-shock protection not only rely on basic insulation, but also take additional safety protection equipment (such as the use of double insulation or reinforcement must Edge of the equipment), such equipment does not rely on the protection of grounding, do not rely on the installation of protective measures. 3.1.3 Class III equipment class Ⅲequipment The anti-shock protection is a device that is powered by a safety extra-low voltage (SELV) circuit and does not generate dangerous voltages. Note 1. The voltage limit under normal operating conditions is less than the specified value in 6.3.1a of GB 4793.1-2007 is considered to be a safety extra-low voltage. Note 2. For Class III equipment, although no anti-shock requirements, but the other requirements of this standard are applicable. 3.2 Protection isolation protectiveseparation Use basic protection and additional protection between circuits (basic insulation plus additional insulation or protective shield) or use such as reinforced insulation The protection of the protective measures.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 32704-2016_English be delivered?

Answer: Upon your order, we will start to translate GB/T 32704-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 32704-2016_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 32704-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information