GB/T 32580.302-2016: Railway applications -- Fixed installations -- Particular requirements for a.c. switchgear -- Part 3-2: Measurement, control and protection devices for specific use in a.c. traction systems -- Single-phase current transformers
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 32580.302-2016English159 Add to Cart 3 days [Need to translate] Railway applications -- Fixed installations -- Particular requirements for a.c. switchgear -- Part 3-2: Measurement, control and protection devices for specific use in a.c. traction systems -- Single-phase current transformers Valid GB/T 32580.302-2016

PDF similar to GB/T 32580.302-2016


Standard similar to GB/T 32580.302-2016

TB/T 3111   GB/T 32580.1   GB/T 32580.2   GB/T 32580.303   

Basic data

Standard ID GB/T 32580.302-2016 (GB/T32580.302-2016)
Description (Translated English) Railway applications -- Fixed installations -- Particular requirements for a.c. switchgear -- Part 3-2: Measurement, control and protection devices for specific use in a.c. traction systems -- Single-phase current transformers
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard S81
Classification of International Standard 29.280
Word Count Estimation 8,824
Date of Issue 2016-04-25
Date of Implementation 2016-11-01
Quoted Standard GB/T 1402-2010; GB 4208-2008; GB 20840.2-2014; GB/T 24338.1; GB/T 24338.2; GB/T 24338.3; GB/T 24338.4; GB/T 24338.5; GB/T 24338.6; GB/T 32580.1-2016
Adopted Standard IEC 62505-3-2-2009, MOD
Regulation (derived from) National Standard Announcement No
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the working conditions, characteristics and application of the single-phase current transformers (referred to as "current transformers"), their ratings and design requirements, primary short-circuit conditions, special design and structural characteristics. This standard applies to the nominal voltage of 25 kV, 50 kV and the frequency of 50 Hz electrified railway power supply system for electrical measurement and protection of current transformers.

GB/T 32580.302-2016: Railway applications -- Fixed installations -- Particular requirements for a.c. switchgear -- Part 3-2: Measurement, control and protection devices for specific use in a.c. traction systems -- Single-phase current transformers



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Railway applications - Fixed installations - Particular requirements for acswitchgear - Part 3-2. Measurement, control and protection devices for specific use in actraction systems - Single-phase current transformers ICS 29.280 S81 National Standards of People's Republic of China Rail transit ground equipment AC switchgear special requirements Part 3-2. AC traction system for special measurement, Control and protection devices Single-phase current transformers Part 3-2. Measurement, controlandprotectiondevicesforspecific (IEC 62505-3-2..2009, MOD) 2016-04-25 release.2016-11-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Management Committee released Directory Preface III 1 Scope 1 2 normative reference document 1 3 Terms and definitions 1 4 working conditions 1 5 Features and Applications 1 6 Rating and design requirements 2 7 primary short circuit condition 2 Special design and structural characteristics 8.1 General 2 8.2 contamination 2 8.3 Floating potential and grounding 2 8.4 Electromagnetic compatibility 2 8.5 connection line 2 8.6 Buyer should be clear information 2 8.7 Supplier should be clear information 3 8.8 Other requirements 3 Appendix A (informative) Technical differences between this part and IEC 62505-3-2..2009 4

Foreword

GB/T 32580 "Special requirements for AC switchgear for rail transit equipment" is divided into the following sections. - Part 1. Single-phase circuit breakers with Un greater than 1 kV; - Part 2. Single - phase disconnectors with Un greater than 1 kV, earthing switches and load switches; - Part 3-1. Guidance on the application of measurement, control and protection devices for AC traction systems; - Part 3-2. Special measurement, control and protection devices for AC traction systems - Single - phase current transformers; Part 3-3. Special measurement, control and protection devices for AC traction systems Single phase inductive voltage transformers. This part is part 3-2 of GB/T 32580. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This section uses the re-drafting method to modify the use of IEC 62505-3-2..2009 "Rail Transit Ground Equipment AC Switchgear Special requirements - Part 3-2. Single - phase current transformers for the measurement, control and protection of AC traction systems. The technical differences between this part and IEC 62505-3-2..2009 are given in Appendix A. This section makes the following editorial changes. --- increase 8.1 "general" to eliminate the suspension section; - Increased Information Appendix A, describing the technical differences between this and the original; --- delete the original reference. This section is made by the National Railway Administration. This part is headed by the National Technical Committee for Standardization of Electrical Equipment and Systems (SAC/TC278). This part of the main drafting unit. China Railway Fourth Survey and Design Institute Group Co., Ltd. This part participates in the drafting unit. Railway Third Survey and Design Institute Group Co., Ltd., China Railway Electrification Survey and Design Institute Co., Ltd. This part of the main drafters. Li Jinjun, Zhang Huazhi. This part participates in the drafters. Zhu Jiang, Tian Shengli, Chen Xingqiang, Ye Chaorong. Rail transit ground equipment AC switchgear special requirements Part 3-2. AC traction system for special measurement, Control and protection devices Single-phase current transformers

1 Scope

This part of GB/T 32580 specifies the operating conditions, characteristics and applications of single-phase current transformers ("current transformers") Valuation and design requirements, primary short-circuit conditions, special design and structural characteristics. This part applies to the electrified railway power supply system with nominal voltage of 25kV, 50kV and frequency of 50Hz. Electrical measurement and protection Of the current transformer.

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. GB/T 1402-2010 Rail Transit Traction Power Supply System Voltage (IEC 60850..2007, MOD) GB 4208-2008 enclosure protection class (IP code) (IEC 60529..2001, IDT) GB 20840.2-2014 Transformers - Part 2. Supplementary technical requirements for current transformers (IEC 61869-2..2012, MOD) GB/T 24338 (all parts) Rail traffic Electromagnetic compatibility (IEC 62236) GB/T 32580.1-2016 Particular requirements for AC switchgear for terrestrial equipment for rail transit - Part 1. Un greater than 1kV single-phase circuit breaker (IEC 62505-1..2009, MOD)

3 terms and definitions

The terms and definitions defined in GB 20840.2-2014 and GB/T 32580.1-2016 apply to this document.

4 working conditions

The equipment described in this part is installed on the circuit breaker specified in GB/T 32580.1-2016, so the work of GB/T 32580.1-2016 The conditions apply to this section. If the current transformer is installed separately with the switch, the operating conditions of the switch are applicable to this section.

5 features and applications

Current transformers should meet. a) Installed inside the circuit breaker specified in GB/T 32580.1-2016 or installed in the special casing of the circuit breaker. Technical requirements and the structural and test requirements of GB/T 32580.1-2016 (if applicable); b) When installed on a separate stand, the technical requirements of this part apply.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 32580.302-2016_English be delivered?

Answer: Upon your order, we will start to translate GB/T 32580.302-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 32580.302-2016_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 32580.302-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information