US$839.00 · In stock Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 32580.1-2016: Railway applications -- Fixed installations -- Particular requirements for a.c. switchgear -- Part 1: Single-phase circuit-breakers with Un above 1kV Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 32580.1-2016 | English | 839 |
Add to Cart
|
7 days [Need to translate]
|
Railway applications -- Fixed installations -- Particular requirements for a.c. switchgear -- Part 1: Single-phase circuit-breakers with Un above 1kV
| Valid |
GB/T 32580.1-2016
|
PDF similar to GB/T 32580.1-2016
Basic data | Standard ID | GB/T 32580.1-2016 (GB/T32580.1-2016) | | Description (Translated English) | Railway applications -- Fixed installations -- Particular requirements for a.c. switchgear -- Part 1: Single-phase circuit-breakers with Un above 1kV | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | S81 | | Classification of International Standard | 29.280 | | Word Count Estimation | 42,420 | | Date of Issue | 2016-04-25 | | Date of Implementation | 2016-11-01 | | Quoted Standard | GB/T 1402-2010; GB 1984-2014; GB 1985-2014; GB/T 2900.1; GB/T 2900.18; GB/T 2900.19; GB/T 2900.20; GB/T 11022 | | Adopted Standard | IEC 62505-1-2009, MOD | | Regulation (derived from) | National Standard Announcement No | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard applies to single-phase alternating current circuit-breakers for indoor or outdoor fixed installations, operating at 50 Hz and nominal voltages of 25 kV, 2 x 25 kV and 50 kV for electrified railway applications. Bipolar circuit breakers to be used in this standard are limited to the connection line on one pole connection line, the other pole is connected to the feeder line, the feeder line is erected along the same track and the autotransformer is connected by a certain distance to improve the line Voltage. The neutral point of the whole circuit is directly grounded. This standard also applies to the operating mechanism of the circuit breaker and its auxiliary equipment. Breakers operated solely by means of manual operation are not covered by this standard. |
GB/T 32580.1-2016: Railway applications -- Fixed installations -- Particular requirements for a.c. switchgear -- Part 1: Single-phase circuit-breakers with Un above 1kV ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Railway applications.Fixed device.Particular requirements for acswitchgear.Part 1. Single-phase circuit-breakers with Un above 1kV
ICS 29.280
S81
National Standards of People's Republic of China
Rail transit ground device AC switch
Special requirements for equipment Part 1.
Un single-phase circuit breakers larger than 1 kV
acswitchgear-Part 1. Single-phasecircuit-breakerswithUnabove1kV
(IEC 62505-1..2009, MOD)
2016-04-25 released
2016-11-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
China National Standardization Management Committee released
Directory
Preface III
1 Scope 1
2 normative reference document 1
3 Terms and definitions 1
4 conditions of use 2
5 rated 2
5.1 Overview 2
5.2 Rated voltage (UNe) 2
5.3 Nominal voltage (Un) 2
Rated insulation voltage (UNm) 2
5.5 Rated frequency 3
5.6 Rated current and temperature rise 3
5.7 Rated short time withstand current 3
5.8 Rated peak withstand current 3
5.9 Rated short circuit duration 3
5.10 Rated power supply voltage for sub-gate and auxiliary circuit 3
5.11 Rated power frequency of the switching device and auxiliary circuit 3
5.12 Rated pressure for compressed air supply for insulation and operation 3
5.13 Rated short-circuit breaking current (INss) 4
5.14 Near-end fault rating TRV 4
5.15 ITRV nominal value 6
5.16 Rated short-circuit closing current 6
5.17 Rated operating sequence 6
5.18 rated out-of-step breaking current 6
5.19 Rated circuit charge breaking current 7
5.20 rated cable charging breaking current 7
5.21 rated single group capacitor bank breaking current 7
5.22 rated back to back capacitor bank breaking current 7
5.23 rated single group of capacitor sets inrush current 8
5.24 Rated time parameter 8
5.25 rating with 9
Design and manufacture
6.1 Requirements for liquids in circuit breakers 10
6.2 Requirements for gases in circuit breakers 10
6.3 grounding of the circuit breaker 10
6.4 Auxiliary equipment 10
6.5 Power closing 10
6.6 Energy storage closing 11
6.7 Release 11
Low - pressure locking device and high - pressure locking device
6.9 Nameplate 11
6.10 Synchronization requirements for each pole
6.11 General requirements for operation 12
6.12 Air Blower Circuit Breaker Compressed Gas Pressure Limit 12
6.13 row hole 12
6.14 Safety overpressure device 12
7 type test 12
7.1 Overview 12
7.2 Insulation test 13
7.3 Radio disturbance voltage test 14
7.4 Temperature rise test 14
7.5 Measurement of main resistance 14
7.6 Short-time withstand current and peak withstand current test 15
7.7 Mechanical tests and environmental tests
7.8 Provisions for closing, breaking and opening and closing tests
7.9 Test circuit for short-circuit closing and breaking test
7.10 Short-circuit test parameters 26
7.11 Short Circuit Test Procedure
7.12 Basic short circuit test 30
7.13 Critical current test 31
7.14 different correlation and breaking test 32
7.15 Capacitive current closing test 32
8 factory inspection 34
8.1 Overview 34
8.2 Main circuit power frequency dry pressure test 34
8.3. Voltage withstand test for control and auxiliary circuits
Measurement of Main Circuit Impedance
8.5 Mechanical Operation Tests 34
8.6 Design Verification and Visualization 35
Guidance on the selection of circuit breakers
10 Information to be provided together with orders, tenders and inquiries
Appendix A (informative) Technical differences between this part and IEC 62505-1..2009 36
Appendix B (informative) Pollution Level 37
Foreword
GB/T 32580 "Special requirements for AC switchgear for rail transit equipment" is divided into the following sections.
- Part 1. Single-phase circuit breakers with Un greater than 1 kV;
- Part 2. Single - phase disconnectors with Un greater than 1 kV, earthing switches and load switches;
- Part 3-1. Guidance on the application of measurement, control and protection devices for AC traction systems;
- Part 3-2. Special measurement, control and protection devices for AC traction systems - Single - phase current transformers;
Part 3-3. Special measurement, control and protection devices for AC traction systems Single phase inductive voltage transformers.
This part is part 1 of GB/T 32580.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This part uses the re-drafting method to modify the special use of IEC 62505-1..2009 "Rail Transit Floor Equipment AC Switchgear
Requirements for fixed devices AC switch control devices - Part 1. Single - phase circuit breakers with Un greater than 1 kV.
The technical differences between this part and IEC 62505-1..2009 are given in Appendix A.
This section makes the following editorial changes.
--- delete the original item 5.14.3 a), d) column items, because no applicable content;
--- delete 7.1 in the "inductive current test" and 7.13.3 "Note. 7.16 related to the test of small inductor current test" content, because
There is no corresponding content in the original IEC , there is an error in the original text;
- Increased Information Appendix A and Appendix B;
--- delete the original reference.
This section is made by the National Railway Administration.
This part is headed by the National Technical Committee for Standardization of Electrical Equipment and Systems (SAC/TC278).
This part of the main drafting unit. China Railway Fourth Survey and Design Institute Group Co., Ltd.
This part participates in the drafting unit. Yongji new speed motor electrical limited liability company, railway third survey and design institute group limited company.
This part of the main drafters. Wu Shuqiang, Li Jinjun.
This part participates in the drafters. Wang Tianbing, Li Liya, Liu Guangqiang, Zheng Shuli, Cui Jianyu.
Rail transit ground device AC switch
Special requirements for equipment Part 1.
Un single-phase circuit breakers larger than 1 kV
1 Scope
GB/T 32580 this part applies to indoor or outdoor fixed installation, operating frequency 50Hz, and the nominal voltage of 25kV, 2 ×
Single - phase AC circuit breakers for 25kV and 50kV electrified railway.
This part of the application of bipolar circuit breaker connection is limited to. one pole connected to the line of contact lines, the other pole is connected to the feed line, positive feedback
The wires are erected along the same track and are connected to the autotransformer by a distance to increase the line voltage. The neutral of the entire loop is direct
Ground.
This part also applies to the operating mechanism of the circuit breaker and its auxiliary equipment.
The circuit breaker that relies solely on the maneuvering mechanism is not within the scope of this part.
NOTE. From a safety standpoint, this section does not specify the rated short-circuit closing current of a manually operated circuit breaker.
2 normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article
Pieces. For undated references, the latest edition (including all modifications) applies to this document.
GB/T 1402-2010 Rail Transit Traction Power Supply System Voltage (IEC 60850..2007, MOD)
GB 1984-2014 High Voltage AC Circuit Breaker (IEC 62271-100..2008, MOD)
High voltage AC disconnectors and earthing switches (IEC 62271-102..2001, MOD)
GB/T 2900.1 Basic terminology for electrical terminology
Low - voltage electrical appliances GB/T 2900.18
GB/T 2900.19 Electrical terminology - High voltage test technology and insulation mating
GB/T 2900.20 Electrotechnical terminology High voltage switchgear
GB/T 11022 high voltage switchgear and control equipment standard common technical requirements
3 terms and definitions
GB/T 2900.19, GB/T 2900.19, GB/T 2900.19, GB/T 2900.20 The following definitions and definitions apply to this
file.
3.1
Single-pole circuit breaker single-polecircuit-breaker
Applicable to single-phase circuit, with a separate electrical circuit can be separated from the main electrical circuit of the circuit breaker.
Note. The structure of the device layout in principle with the three-phase circuit breaker single-phase structure is equivalent.
3.2
Bipolar circuit breaker two-polecircuit-breaker
In the main circuit itself has two independent electrical conduction channel isolation device.
Note 1. In a single-phase circuit, the poles are connected in series and turned on and off at the same time.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 32580.1-2016_English be delivered?Answer: Upon your order, we will start to translate GB/T 32580.1-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 32580.1-2016_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 32580.1-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|