GB/T 29416: Evolution and historical versions
| Std ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status |
| GB/T 29416-2026 | English | RFQ |
ASK
|
3 days [Need to translate]
|
Test method for fire-resistant performance of external wall insulation systems applied to building facades
| Valid |
| GB/T 29416-2012 | English | 399 |
Add to Cart
|
3 days [Need to translate]
|
Test method for fire-resistant performance of external wall insulation systems applied to building facades
| Valid |
Standard similar to GB/T 29416-2026
GB/T 26784 | GB 15930 | GB 16840.2 | GB/T 12513 | GB 29415 |
Basic data
| Standard ID | GB/T 29416-2026 (GB/T29416-2026) |
| Description (Translated English) | Test method for fire-resistant performance of external wall insulation systems applied to building facades |
| Sector / Industry | National Standard (Recommended) |
| Classification of Chinese Standard | C82 |
| Classification of International Standard | 13.220.50 |
| Date of Issue | 2026-03-31 |
| Date of Implementation | 2026-10-01 |
| Older Standard (superseded by this standard) | GB/T 29416-2012 |
| Issuing agency(ies) | State Administration for Market Regulation, Standardization Administration of China |
GB/T 29416-2012: Test method for fire-resistant performance of external wall insulation systems applied to building facades
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Test method for fire-resistant performance of external wall insulation systems applied to building facades
ICS 13.220.50
C82
National Standards of People's Republic of China
Fire performance of building exterior insulation system
experiment method
Issued on. 2012-12-31
2013-10-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
The reference standard preparation BS8414-1.2002 "fire performance of building external cladding systems - Part 1. Non-suitable for building surfaces
Test methods "outer envelope bearing system.
The standard proposed by the People's Republic of China Ministry of Public Security.
This standard by the National Standardization Technical Committee member fire building fire resistance of the Technical Committee (SAC/TC113/SC8) centralized.
This standard is drafted by. Ministry of Public Security in Tianjin Fire Research Institute.
Participated in the drafting of this Standard. China Academy of Building Research, Ministry of Public Security of Sichuan Fire Research Institute, Beijing-profit high-tech Co., Ltd.,
Quan Chemical Co., Ltd. Shandong, China Polyurethane Industry Association.
The main drafters of this standard. Wang Guohui, Tian Liang, Zhuo Ping, Zhang Xiaoying, Zhao Bi, Han Weiping, item Kai, Hu Shengli, Wu Yingjie, quaternary its wide, Zhao
Gang Cui Ronghua, HUANG Zhen-li, Tang Lulin, Li Jianbo, Zhu Chunling, Jianqiang, Hu Teng, Zhang Zhimin.
Fire performance of building exterior insulation system
experiment method
Warnings. organization and all those involved in this trial need watch out for hazards that may exist. There may be outside during the test
Insulation system fully burn and produce toxic and (or) harmful fumes, fumes case, after the specimen installation, testing and implementation of clear test residue
Management process mechanical hazards and dangerous operation may also occur. Therefore, laboratory testing personnel to be equipped with safety equipment and the corresponding
Fire-fighting facilities, all potential hazards and assess the health risks and make safety notice. Test personnel make the necessary
Training to ensure that staff follow safety procedures to operate.
1 Scope
This standard specifies the terms and definitions of the building exterior insulation system fire performance testing, test equipment, sample conditioning, the test drive
Order, inspection after the test, the test results to determine and test reports.
The fire performance test standard suitable for installation on non-load bearing exterior wall external insulation system.
This standard does not apply to fire resistance test mounted on the outside of the building's exterior glass curtain wall insulation respiratory system.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 5907 fire first part basic terms
GB/T 6343 and foam rubber Determination of apparent density
GB/T 18404 sheathed thermocouple cables and thermocouples
Monomer GB/T 20284 building materials and products of combustion test
GB/T 25181 ready-mixed mortar
3 Terms and Definitions
GB/T 5907 defined by the following terms and definitions apply to this document.
3.1
Building exterior insulation system externalwalinsulationsystemsappliedtobuildingfacade
The structures will adopt the provisions of various materials mounted on the outer surface of the external walls of the building, with a complete structural system of a certain insulation properties.
3.2
Level 1 level1 horizontal lines
Located in the combustion chamber opening test level Level top line at the top of 2500mm.
3.3
Level 2 level2 horizontal lines
Located in the combustion chamber opening test level Level top line at the top of 5000mm.