GB/T 28534-2012: The health and environmental impact on release of sulphur hexafluoride (SF6) used in high-voltage switchgear and controlgear
Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 28534-2012 | English | 1149 |
Add to Cart
|
8 days [Need to translate]
|
The health and environmental impact on release of sulphur hexafluoride (SF6) used in high-voltage switchgear and controlgear
| Valid |
GB/T 28534-2012
|
PDF similar to GB/T 28534-2012
Basic data
| Standard ID | GB/T 28534-2012 (GB/T28534-2012) |
| Description (Translated English) | The health and environmental impact on release of sulphur hexafluoride (SF6) used in high-voltage switchgear and controlgear |
| Sector / Industry | National Standard (Recommended) |
| Classification of Chinese Standard | K43 |
| Classification of International Standard | 29.130.10 |
| Word Count Estimation | 52,564 |
| Quoted Standard | GB 1984; GB/T 2900.20-1994; GB 7144; GB/T 8905; GB/T 11022-2011; GB/T 12022; GB/T 28537-2012 |
| Adopted Standard | IEC 62271-303-2008, MOD |
| Regulation (derived from) | National Standards Bulletin No. 13 of 2012 |
| Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
| Summary | This standard applies to the high-voltage switchgear and control equipment, normal and abnormal operation SF6 handling and personnel safety and environmental compatibility of procedures, including the storage and transportation of SF6 and personnel traini |
GB/T 28534-2012: The health and environmental impact on release of sulphur hexafluoride (SF6) used in high-voltage switchgear and controlgear
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
The health and environmental impact on release of sulphur hexafluoride (SF6) used in high-voltage switchgear and controlgear
ICS 29.130.10
K43
National Standards of People's Republic of China
High-voltage switchgear and control equipment in sulfur hexafluoride (SF6)
The impact of the release of gases on the environment and health
Thehealthandenvironmentalimpactonreleaseofsulphurhexafluoride (SF6)
[IEC 62271-303.2008, High-voltageswitchgearandcontrolgear-
Part 303. Useandhandlingofsulphurhexafluoride (SF6), MOD]
Issued on. 2012-06-29
2012-11-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅴ
Introduction Ⅵ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 SF6 storage and transport 4
4.1 Overview 4
4.2 storage container filled with SF6 4
4.3 transport container containing SF6 5
4.4 SF6-filled electrical equipment storage and transportation 6
4.5 Liability 6
5 safety and emergency rescue 6
5.1 GENERAL SAFETY RULES 6
5.2 In the case of abnormal release of SF6 fire due to external and internal arc fault caused by an additional security measure 9
5.3 emergency equipment and handling 10
6 Training and certification 11
6.1 Overview 11
6.2 Training Module 11
6.3 Certificate 13
Category 7 SF6 processing device 13
7.1 Overview 13
7.2 Recovery 14
7.3 hose connection 16
Portable gas measurement equipment 7.4 16
7.5 gas sample cylinder 18
Appendix A (informative) sulfur hexafluoride 19
A.1 Introduction 19
A.2 chemical properties 19
A.3 Physical Characteristics 19
A.4 Electrical characteristics 20
A.5 treatment, health hazards and characteristics of 21
Appendix B (Informative Appendix) SF6 environmental impact 22
B.1 Introduction 22
B.2 Ecotoxicology 22
B.3 ozone depletion 22
B.4 global warming and climate change (greenhouse effect) 22
B.5 byproducts 23
B.6 SF6 environmental policy compatible 23
Appendix C (Informative Appendix) SF6 byproducts 24
C.1 SF6 decomposition 24
C.2 SF6 and corrosive byproducts 250,000
C.3 Clear SF6 byproducts measures 26
Physiological characteristics C.4 SF6 byproducts 26
The potential impact of Appendix D (Informative Appendix) SF6 byproducts Health 27
D.1 Introduction 27
D.2 Summary 27
D.3 SF6 byproducts generated and its impact on health 27
D.4 byproduct concentration calculation 29
D.5 evaluation results 38
D.6 Conclusions 38
D.7 data used to calculate 38
D.8 action limit 41
References 43
1 Universal Recovery 14
Figure A.1 SF6 pressure/temperature/density characteristics 20
Table 1 SF6 storage method 4
Table 2 SF6 type labels and transport and storage containers 5
Table 3 SF6 international transport regulations summary 6
Table measures in SF6 electrical equipment when operating 47
Security measures Table 5 open and/or close to the time of the inflatable compartments 8
Table 6 and 8 programs
Table 7 Additional security measures 10
A typical filter used in Table 8 SF6 recovery during the Type 15
Table 9 gas measurement apparatus 17
Table A.1 SF6 main chemical characteristics of 19
Table A.2 SF6 main physical characteristics of 20
Table A.3 SF6 main electrical characteristics of 21
Table D.1 SOF2, SO2, HF and S2F10 the TLV 30
Table D.2 leaks example calculations 32
Table D.3 Considering the SOF2 hydrolysis for leaks result 32
Examples Table D.4 partial discharge S2F10 concentration calculation 34
Examples Table D.5 corona discharge S2F10 concentration calculation 34
Table S2F10 concentration D.6 isolation switch sparks computing example 35
Table D.7 internal faults instance SOF2 concentration calculation 36
Table D.8 inflatable volume and pressure switch device 39
Table D.9 arc energy when it is open 39
Table D.10 internal arc fault energy 39
Table D.11 SOF2 generation rate 40
Table D.12 generated SOF2 number 40
Table D.13 SF6 leakage rate of 41
Table D.14 SOF2 leakage rate of 41
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard uses redrafted law revision using IEC 62271-303.2008 "high-voltage switchgear and control equipment Part 303. Six
Sulfur hexafluoride (SF6) for use and handling. "
This standard and IEC 62271-303.2008 technical differences and for the following reasons.
--- Delete irrelevant to the standard IEC 62271-303 in Chapter 7. During the installation process and the transfer of SF6, Chapter 8. make normal
SF6 used during the life process, Chapter 9. Maintenance during the recovery and recycling of SF6, Chapter 10. At the end of life SF6 Power
Disassemble the device.
The standard proposed by China Electrical Equipment Industrial Association.
This standard by the national high-voltage switch equipment Standardization Technical Committee (SAC/TC65) centralized.
This standard was drafted. Xi'an High Voltage Apparatus Research Institute Co., Ltd., Xi'an High Voltage Switch Co., Ltd., New Northeast Electric
Gas (Shenyang) High Voltage Switchgear Co., Ltd., Shanghai days Ling Switch Factory Co., Limited ABB (China) Co., Ltd., Beijing Northern Electric shares
Company, Jiangsu Province, such as high-pressure high Appliance Co., Ltd., Shanghai Electric Power Transmission Test Center Co., Ltd., Xiamen ABB High Voltage Switchgear Co.,
Secretary, Guangdong Fan Electric Equipment Manufacturing Co., Ltd., Shantou Zhengchao Electric Group Co., Ltd., Shenzhen Institute of Electrical Science, Ningbo Tianan set
Group benefits and Electric Group Co., Ltd., Zhejiang Switch Factory Co., Ltd., Henan high level of electrical Co., Ltd., Xi'an Electrical Switch
Ltd., Schneider Electric (China) Investment Co., Ltd. Taixing Branch Lide refrigeration equipment.
The main drafters of this standard. Xing Na, Wu Hongyan, South Zhiyong, Huang Chao, Chen Zhibin, Li Xinchun, Zhangcheng Bo, Sun Kuaigang, Xie Jianbo, Li Jinling,
Baby Lee, Lu-an, Shen Liang, Lin Fuming, Yang Kun, Shi Gang, Ningmao Liang, Guan Xing Yan, Shen Chun Ming Lei Xiaoqiang, Feng Xiaohong, Xiaomin Ying, Mo Kang,
Deng Yonghui.
Introduction
SF6 gas used in electrical switchgear and control equipment for over 30 years. It is mainly used for rated voltage above 1kV until the
There has manufactured the highest rated voltage switchgear and control equipment. It is estimated that there are several million units filled with different types of
SF6 units in operation.
According to GB/T 11022, there are three kinds of gas system is technically available.
--- Controllable pressure systems;
Note 1. Because unacceptable leak rate (see GB 7674), the new equipment is no longer controllable pressure systems.
--- Closed pressure systems. For the standard modern electrical equipment per year leak rate is 0.5% and 1% each inflatable compartments;
--- Sealed pressure system. For a modern medium voltage electrical equipment (commercially known as "lifelong seal products" or "hermetically sealed system"), the seal
Sealing pressure of the system to the provisions of its expected life. Leakage performance with respect to life expectancy by the manufacturer to regulate
set. Preferably of 20 years, 30 years and 40 years.
Note 2. In order to meet the anticipated requirements of life, that the annual rate of the leak sealed pressure system is less than 0.1%.
Electrical switching and control equipment used in the long-term experience has shown that SF6, as long as the establishment and comply with certain basic precautions and procedures
Order, to benefit the operation, safety and working environment, for example.
--- Safe operation of equipment;
--- Optimization of resources and tools;
--- Minimize equipment downtime of;
--- SF6 Processing Standards trainers;
--- Emissions during gas processing operation is reduced to below the limit of physical function;
--- Avoid any deliberate emissions, such as emissions into the atmosphere;
--- During the transfer, use, operation and end of life processing SF6 consumption and emissions to a minimum.
Recently, on the latest technology in SF6 switchgear and control practices recommended by the equipment has been studied by the committee CIGREB3
B3.02 Working Group will be published [1]. This information is used to develop this standard.
High-voltage switchgear and control equipment in sulfur hexafluoride (SF6)
The impact of the release of gases on the environment and health
1 Scope
This standard applies to the high-voltage switchgear and control equipment, normal and abnormal operation and environmental safety as well as personnel and handling SF6
Yung procedures, including the storage and transport as well as training of personnel of SF6.
Should be considered in these procedures is to ensure the safety of personnel working SF6 and SF6 emissions will be the most minimal to the environment reduced the number of
Low demand.
This standard is generally applicable to a mixed gas of SF6.
Note 1. In order to facilitate the use of this standard, the voltage range of high-voltage switchgear in the usual sense generally refers to the rated voltage of 3.6kV and above. Practical applications,
Rated voltage range is typically medium voltage switchgear is 3.6kV ~ 63kV; Rated voltage range of high-voltage switchgear is 72.5kV ~ 252kV; ultrahigh
Rated voltage range voltage switchgear is 363kV ~ 800kV; rated voltage range UHV switchgear is 1100kV and above.
Note 2. The entire Standard, the term "electrical equipment" stands for "high-voltage and medium-voltage switchgear and/or control devices."
In this standard, may not contain all the existing rules on SF6 (procedure), it is mainly security concerns, given the normal
And abnormal operating conditions during the switching and control equipment used in SF6 for the object of the basic knowledge and guidance.
These proposals should ensure that staff as SF6 for the object to secure minimum requirements.
This standard applies to filled with switching and control equipment, industrial pure SF6 gas.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB 1984 high voltage AC circuit breaker (GB/T 1984-2003, IEC 62271-100, MOD)
GB/T 2900.20-1994 Electrotechnical terminology voltage switchgear (IEC 60050, NEQ)
GB 7144 cylinders color logo
GB/T 8905 sulfur hexafluoride gas in electrical equipment management and testing guidelines (GB/T 8905-1996, IEC 60480, NEQ)
GB/T 11022-2011 high-voltage switchgear and control equipment standard common technical requirements (IEC 62271-1.2007, MOD)
GB/T 12022 Industrial sulfur hexafluoride (GB/T 12022-2006, IEC 376, IEC 376A, IEC 376B, MOD)
GB/T 28537-2012 high-voltage switchgear and control equipment in sulfur hexafluoride (SF6) for use and handling (IEC 62271-303.
2008, MOD)
3 Terms and Definitions
GB/T 2900.20-1994 defined and the following terms and definitions apply to this document.
Note. Many different types of switches and control equipment are used SF6 gas as insulation and/or arc-quenching medium.
3.1
Sulfur hexafluoride (SF6) abnormal release abnormalreleaseofsulphurhexafluoride (SF6)
Pressure system failures caused by the release of SF6 from a running device.
NOTE. abnormal release of SF6 is generally undesirable and continuous gas emissions. Just SF6 leak abnormality is detected, appropriate measures should be taken immediately set
Bit and reduce leakage.
Tips & Frequently Asked Questions:
Question 1: How long will the true-PDF of GB/T 28534-2012_English be delivered?
Answer: Upon your order, we will start to translate GB/T 28534-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 5 ~ 8 working days. The lengthier the document the longer the lead time.
Question 2: Can I share the purchased PDF of GB/T 28534-2012_English with my colleagues?
Answer: Yes. The purchased PDF of GB/T 28534-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.
Question 3: Does the price include tax/VAT?
Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs):
List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?
Answer: Yes. If you need your currency to be printed on the invoice, please write an email to
[email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.