US$1674.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 28446.1-2012: Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices -- Human models, instrumentation, and procedures -- Part 1: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in clo Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 28446.1-2012 | English | 1674 |
Add to Cart
|
5 days [Need to translate]
|
Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices -- Human models, instrumentation, and procedures -- Part 1: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in clo
| Valid |
GB/T 28446.1-2012
|
PDF similar to GB/T 28446.1-2012
Basic data | Standard ID | GB/T 28446.1-2012 (GB/T28446.1-2012) | | Description (Translated English) | Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices -- Human models, instrumentation, and procedures -- Part 1: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in clo | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | L06 | | Classification of International Standard | 17.240 | | Word Count Estimation | 84,879 | | Quoted Standard | ISO/IEC GUIDE-1995; ISO/IEC 17025-1999 | | Adopted Standard | IEC 62209-1-2005, IDT | | Regulation (derived from) | National Standards Bulletin No. 13 of 2012 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the use of emission portion close to the ear using a handheld wireless communication device specific absorption rate assessment procedures. This section applies to the operating frequency range of 300 MHz ~ 3 GHz arbitrary electrom |
GB/T 28446.1-2012: Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices -- Human models, instrumentation, and procedures -- Part 1: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in clo
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS17.240
L06
National Standards of People's Republic of China
GB/T 28446.1-2012/IEC 62209-1.2005
Hand-held and body-worn use wireless communication devices
The body's electromagnetic radiation Human models, instrumentation, and procedures
Part 1. close to the ear using a handheld wireless
SAR assessment procedures communication device (frequency range
300MHz ~ 3GHz)
wirelesscommunicationdevices-Humanmodels, instrumentation, and
procedures-Part 1. Proceduretodeterminethespecificabsorptionrate (SAR)
(IEC 62209-1.2005, IDT)
Issued on. 2012-10-01 2012-06-29 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 Symbols and abbreviations 8
4.1 8 physical
4.2 constant 8
9 4.3 Acronym
5 Measurement System Specification 9
5.1 General requirements 9
5.2 Model Specifications (shell and liquid) 9
5.3 SAR measurement equipment specifications 12
13 5.4 Scanning System Specifications
5.5 Equipment specifications jig 13
5.6 Measurement of liquid dielectric properties 13
6 SAR assessment procedures 13
6.1 Preparation for measurement 13
17 measuring 6.2 to be executed
6.3 Measurement procedure 18
Post-processing of the measured data 6.4 SAR 19
7 Evaluation of Uncertainty 19
7.1 General considerations 19
7.2 Uncertainty components distribution 21
7.3 Evaluation of Uncertainty 29
8 requires measurement report 31
8.1 Overview 31
8.2 Measurement report content should be recorded in 31
Appendix A (normative) model Specifications 32
Calibration and Uncertainty Appendix B (normative) evaluation of the measuring instrument 37
Processing and Evaluation of Uncertainty Appendix C (normative) after 49
Annex D (normative appendix) SAR measurement system verification system 53
Annex E (informative) inter-laboratory comparison 59
Defined in Appendix F (informative) model coordinate system and the coordinate system of the device under test 61
Annex G (informative) Calibration dipole 62
Appendix H (informative) flat model 64
GB/T 28446.1-2012/IEC 62209-1.2005
Annex I (informative) Recommended head tissue simulant liquid formulations of 66
Appendix J (informative) to evaluate the measurement uncertainty and dielectric properties of the liquid 68
References 76
GB/T 28446.1-2012/IEC 62209-1.2005
Foreword
GB/T 28446 "hand-held and body-worn wireless communication devices use electromagnetic radiation on the human body mannequins, instruments and procedures" points
Into two parts.
--- Part 1. close to the hand-held wireless communication devices use at the ear of the SAR assessment procedures (frequency range 300MHz ~
3GHz);
--- Part 2. hand-held and body-worn device in human head and evaluate SAR procedures within the body (frequency range of 300MHz ~
6GHz).
This is Part 1 GB/T 28446 in.
Rules in this section in accordance with GB/T 1.1-2009 given draft.
This section is GB 21288-2007 standard measurement method "local mobile phone electromagnetic radiation exposure limits," the.
This section uses the translation method identical with IEC 62209-1.2005 electricity "Handheld and wireless communication devices use a body-worn on the human body
Magnetic irradiation Human models, instrumentation, and procedures - Part 1. close to the hand-held wireless communication devices use at the ear of the SAR assessment procedures (frequency
Frequency range 300MHz ~ 3GHz) ".
This part made the following editorial changes.
--- For ease of reading, increase the number of formulas in the text.
This part of the National human exposure related to electric, magnetic and electromagnetic field evaluation method Standardization Technical Working Group and centralized.
This section drafted by. China Institute of Metrology, Telecommunications Research Institute of the Ministry of Industry and Information Technology, Qingdao Haier Communications Limited.
The main drafters of this section. Tengjun Heng, Lubing Song, Qi Dian Yuan, Shen Qing Fei, Song Chunguang.
GB/T 28446.1-2012/IEC 62209-1.2005
Hand-held and body-worn use wireless communication devices
The body's electromagnetic radiation Human models, instrumentation, and procedures
Part 1. close to the ear using a handheld wireless
SAR assessment procedures communication device (frequency range
300MHz ~ 3GHz)
1 Scope
This section GB/T 28446 provisions emission portion near the handheld wireless communication device ear of specific absorption rate when using Review
Estimation procedures. This section applies to any electromagnetic fields in the frequency range 300MHz ~ 3GHz transmitting devices, such as mobile phones, cordless
Telephone.
The purpose of this section is to demonstrate how to measure the SAR value of the device under test according to the corresponding limit.
2 Normative references
The following documents for the application of this Act is essential. For dated references, only the dated edition applies to this article
Member. For undated references, the latest edition (including any amendments) applies to this document.
ISO /IEC Guide.1995 Evaluation and Expression of Uncertainty in Measurement (Guidetotheexpressionofuncertaintyinmeas-
urement)
ISO /IEC 17025.1999 Testing and Calibration Laboratory Accreditation Standards (Generalrequirementsforthecompetenceof
testingandcalibrationlaboratories)
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
Attenuation coefficient attenuationcoeffcicent
Mathematics is used to indicate the attenuation factor affected the human head or body tissue resulting from the presence of the source and the particular point.
3.2
Time average absorbed power average (temporal) absorbedpower
Time average absorbed power value according to equation (1) is given by.
Pavg = 1t2-t1∫
t2
t1
P (t) dt (1)
Where.
Pavg --- average power in watts (W);
--- Initial time T1 of electromagnetic radiation, in seconds (S);
Deadline t2 --- electromagnetic radiation, in seconds (s);
t2-t1 --- electromagnetic radiation time in seconds (S);
P (t) --- instantly absorbed power in watts (W).
GB/T 28446.1-2012/IEC 62209-1.2005
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 28446.1-2012_English be delivered?Answer: Upon your order, we will start to translate GB/T 28446.1-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 28446.1-2012_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 28446.1-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|