GB/T 26835-2011: Non-destructive testing instruments -- General specification for industrial X-ray computed tomography (CT) equipment
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 26835-2011English439 Add to Cart 4 days [Need to translate] Non-destructive testing instruments -- General specification for industrial X-ray computed tomography (CT) equipment Valid GB/T 26835-2011

PDF similar to GB/T 26835-2011


Standard similar to GB/T 26835-2011

GB/T 36015   GB/T 36017   GB/T 26837   GB/T 26838   GB/T 26832   GB/T 26830   

Basic data

Standard ID GB/T 26835-2011 (GB/T26835-2011)
Description (Translated English) Non-destructive testing instruments -- General specification for industrial X-ray computed tomography (CT) equipment
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard N78
Classification of International Standard 19.100
Word Count Estimation 19,189
Date of Issue 2011-07-29
Date of Implementation 2011-12-01
Quoted Standard GB/T 191; GB/T 12604.2-2005; GB/T 13384; GB 18871; JB/T 9329
Regulation (derived from) Announcement of Newly Approved National Standards No. 12 of 2011
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the industrial X -ray CT apparatus of terms and definitions, the basic structure, requirements, performance parameters, test methods, inspection rules, marking, packaging, transport and storage. This standard applies to low-energy X- ray tube X-ray source and the use of high-energy electron linear accelerator X-ray source of fixed and mobile industrial X -ray CT apparatus.

GB/T 26835-2011: Non-destructive testing instruments -- General specification for industrial X-ray computed tomography (CT) equipment


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Non-destructive testing instruments. General specification for industrial X-ray computed tomography (CT) equipment ICS 19.100 N78 National Standards of People's Republic of China Nondestructive testing equipment Industrial X-ray CT devices General GeneralspecificationforindustrialX-raycomputedtomography (CT) equipment Issued on. 2011-07-29 2011-12-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Preface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions The basic structure of 2 4 5 Requirement 2 5.1 Specimen range 2 5.2 Detection Time 2 Slice thickness 2 5.3 5.4 reconstruction matrix 2 5.5 defect detection capability 2 6 Performance Parameter 2 6.1 Focus 2 6.2 ray dose rate 2 6.3 Spatial resolution 2 6.4 density resolution 2 6.5 cursor positioning accuracy 2 7 Test Method 3 Spatial resolution 7.1 Test 3 7.2 density resolution test 4 7.3 Position the cursor measurement accuracy 5 8 5 Inspection Rules 8.1 product testing factory 5 8.2 Type inspection 5 9 signs, packaging, transportation and storage 6 9.1 6 logo 9.2 Packaging 6 9.3 Transportation and storage 7 Appendix A (normative) Method Round Passes test card test spatial resolution 8 Annex B (informative) algorithm flow test disc method 10 References 15

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. The standard proposed by China Machinery Industry Federation. This standard by the National Standardization Technical Committee tester (SAC/TC122) centralized. This standard is drafted by. Liaoning Instrument Research Institute, Chinese Academy of Engineering Physics, Institute of Electronics. Participated in the drafting of this standard. Dandong NDT Equipment Co., Ltd., Dandong Huari Rigaku Denki Co., Ltd., four Chuan Ruidi ray Digital Imaging Technology Co., Ltd., Dandong City Wanquan NDT Instrument Factory, Dandong City Testing Instrument Factory. The main drafters of this standard. Wutai Feng, Yu Zhijun, Chen Hao, Dong Diangang, Shao Defeng forward, Zhang, Fan Yongfeng. Nondestructive testing equipment Industrial X-ray CT devices General

1 Scope

This standard specifies the terms and definitions of industrial X-ray CT apparatus (hereinafter referred to as CT apparatus), the basic structure, requirements, performance parameters The number of test methods, inspection rules, marking, packaging, transportation and storage. This standard applies to the use of low-energy X-ray tube X-ray source and the use of high-energy electron linear accelerator X-ray source is fixed and Portable industrial X-ray CT apparatus.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 191 Packaging - Pictorial signs (GB/T 191-2008, ISO 780.1997, MOD) GB/T 12604.2-2005 Terminology for nondestructive testing radiographic testing (ISO 5576.1997, IDT) GB/T 13384 mechanical and electrical products packaging General technical conditions GB 18871 ionizing radiation protection and safety of radiation sources basic standards JB/T 9329 Instrumentation transport, transportation, storage and basic environmental conditions and test methods

3 Terms and Definitions

GB/T 12604.2-2005 and as defined in the following terms and definitions apply to this document. 3.1 Emitter radiationsource Means (e.g., gamma ray source or the X-ray tube) capable of emitting ionizing radiation. 3.2 Detector detectionsystem Is information about the sensor test object is used for processing shifts around the test object into the electronic sensing device containing radioactive electrical information Sub-signals. 3.3 Electrical radiation generators electricalradiationgenerators Generating spot size of a few millimeters to a few microns in the X-ray appliances. 3.4 X-ray CT apparatus X-rayComputedTomography (CT) equipment X-ray emission as an energy source, the use of industrial computer tomography testing apparatus. 3.5 Control area controledarea In one area of \u200b\u200bradiation in the workplace division within this area require or may require to take special protective measures and safety measures, In order to. a) under normal operating conditions to control or prevent the spread of contamination normal irradiation; b) to prevent or limit its potential exposure program.