US$209.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 26832-2011: Non-destructive testing instruments -- Specifications for the wire rope electromagnetic tester Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 26832-2011 | English | 209 |
Add to Cart
|
3 days [Need to translate]
|
Non-destructive testing instruments -- Specifications for the wire rope electromagnetic tester
| Valid |
GB/T 26832-2011
|
PDF similar to GB/T 26832-2011
Basic data | Standard ID | GB/T 26832-2011 (GB/T26832-2011) | | Description (Translated English) | Non-destructive testing instruments -- Specifications for the wire rope electromagnetic tester | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | N78 | | Classification of International Standard | 19.100 | | Word Count Estimation | 9,910 | | Date of Issue | 2011-07-29 | | Date of Implementation | 2011-12-01 | | Quoted Standard | GB/T 191; GB/T 6587.2-1986; GB/T 6587.3-1986; GB/T 6587.4-1986; GB/T 9969.1; GB/T 13384; GB/T 20737; GB/T 21837-2008; JB/T 9329; GB/T 6587.5-1986; GB/T 8706 | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 12 of 2011 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the ferromagnetic wire rope electromagnetic detection equipment technical condition. This Standard applies to detect local damage and loss of metallic cross-sectional area of ??the various types of defects in ferromagnetic wire rope electromagnetic detection equipment. |
GB/T 26832-2011: Non-destructive testing instruments -- Specifications for the wire rope electromagnetic tester ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Non-destructive testing instruments. Specifications for the wire rope electromagnetic tester
ICS 19.100
N78
National Standards of People's Republic of China
Nondestructive testing equipment
Rope electromagnetic detector technical conditions
Issued on. 2011-07-29
2011-12-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 2 Technical Requirements
4.1 Environmental Requirements 2
4.2 Performance Requirements 2
4.3 Stability and environmental testing requirements 2
4.4 appearance quality and structure 2
5 Test Method 2
5.1 Test Environment Condition 2
5.2 The main test instrument 2
5.3 Comparative Sample 2
5.4 Performance Test 2
5.5 Environmental Test 3
5.6 appearance and structure inspection 3
6 3 Product Inspection
6.1 Type test 3
6.2 factory inspection 3
7 signs, packaging, transportation and storage 4
7.1 marks 4
7.2 Packaging 4
7.3 Transportation and storage 4
Foreword
The standard proposed by China Machinery Industry Federation.
This standard by the National Standardization Technical Committee tester (SAC/TC122) centralized.
This standard was drafted. Huazhong University of Science and Technology, Beijing Institute of lifting machinery, Chinese Academy of special equipment, Wuhan University, Beijing Gean
Thai Nondestructive Testing Technology Co., Ltd., Shenzhen City, measuring Detection Technology Co., Ltd.
The main drafters of this standard. Kang Yihua, Wuxin Jun, Liu Jing of the Shen Gong Tian, \u200b\u200bChen Gui thick, Social Democratic Jia, Zhu Ping.
Nondestructive testing equipment
Rope electromagnetic detector technical conditions
1 Scope
This standard specifies the electromagnetic detection equipment and technical conditions ferromagnetic wire rope.
This standard is applicable to the detection of local damage and loss of metallic cross-sectional area of \u200b\u200bthe various types of defects in ferromagnetic wire rope electromagnetic detection equipment.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 191 Packaging - Pictorial signs
GB/T 6587.2-1986 electronic measuring instruments Temperature Test
GB/T 6587.3-1986 electronic measuring instruments humidity test
GB/T 6587.4-1986 electronic measuring instrument vibration test
GB/T 6587.5-1986 electronic measuring instruments impact test
GB/T 8706 wire rope terminology, designation and classification
GB 9969.1 Instructions General Industrial Products
GB/T 13384 mechanical and electrical products packaging General technical conditions
GB/T 20737 Non-destructive testing - General terms and definitions
GB/T 21837-2008 ferromagnetic wire rope electromagnetic detection method
JB/T 9329 Instrumentation transport, transportation, storage and basic environmental conditions and test methods
3 Terms and Definitions
GB/T 8706, GB/T 20737 and GB/T 21837 and established the following terms and definitions apply to this standard.
3.1
Local damage detection sensitivity LFtestingsensitivity
Detector can detect the smallest local damage.
3.2
Sectional area of \u200b\u200bthe metal loss detection sensitivity LMAtestingsensitivity
Minimum metal detector can detect the loss of cross-sectional area.
3.3
Dual function detector dual-functioninstrument
Detector can detect and display the cross sectional area of \u200b\u200bthe metal loss (LMA) changes simultaneously detect and display local damage (LF), this detection
Instrument signal recording apparatus may be a computer, chart recorder or other matching equipment.
3.4
Single-function detector single-functioninstrument
Detector can not detect and display the metal loss varying cross-sectional area and the local damage, can detect and display the one that seized
Tester signal recording apparatus may be a computer, chart recorder or other matching equipment.
|