HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB/T 26218.3-2011 English PDF

US$439.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 26218.3-2011: Selection and dimensioning of high-voltage insulators intended for use in polluted conditions -- Part 3: Composite insulators for a.c. systems
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 26218.3-2011English439 Add to Cart 4 days [Need to translate] Selection and dimensioning of high-voltage insulators intended for use in polluted conditions -- Part 3: Composite insulators for a.c. systems Valid GB/T 26218.3-2011

PDF similar to GB/T 26218.3-2011


Standard similar to GB/T 26218.3-2011

DL/T 1000.1   DB12/ 356   DL/T 1000.3   GB/T 44179   GB/T 26218.4   GB/T 26218.2   

Basic data

Standard ID GB/T 26218.3-2011 (GB/T26218.3-2011)
Description (Translated English) Selection and dimensioning of high-voltage insulators intended for use in polluted conditions -- Part 3: Composite insulators for a.c. systems
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K48
Classification of International Standard 29.080.10
Word Count Estimation 19,151
Date of Issue 2011-12-30
Date of Implementation 2012-05-01
Quoted Standard GB/T 2900.8-2009; GB/T 24622-2009; GB/T 26218.1-2010
Adopted Standard IECTS 60815-3-2008, MOD
Regulation (derived from) Announcement of Newly Approved National Standards No. 22 of 2011
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard provides specific insulator substantially in some filthy environment characteristics determine guidelines and principles. This section applies to filthy conditions, high voltage AC system with composite insulators selection and sizing. The contents of this section CIGRE 33. 13 TF 01 [1] [2] file basis, I want to study in depth the performance of insulators under polluted conditions researchers can put the file as a useful supplement.

GB/T 26218.3-2011: Selection and dimensioning of high-voltage insulators intended for use in polluted conditions -- Part 3: Composite insulators for a.c. systems


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Selection and dimensioning of high-voltage insulators intended for use in polluted conditions Part 3. Composite insulators for acsystems ICS 29.080.10 K48 National Standards of People's Republic of China High voltage insulators under filthy conditions of use Selection and sizing Part 3. composite insulators for ac systems Part 3. Compositeinsulatorsfora.c.systems (IEC /T S60815-3.2008Selectionanddimensioningof Part 3. Polymerinsulatorsfora.c.systems, MOD) Issued on. 2012-05-01 2011-12-30 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Preface Ⅰ 1 Scope and purpose 1 2 Normative references 1 3 Terms, Definitions and Abbreviations 1 3.1 Terms and definitions 3.2 Abbreviations 1 4 Principle 2 5 material 2 General Information 5.1 silicone rubber umbrella cover material 2 5.2 creepage distance is reduced 2 6 site pollution degree determination 3 7 Reference Unified creepage distance is determined (RUSCD) 3 Generally recommended eight pairs of composite insulators umbrella 4 9 umbrella check parameters 5 9.1 Overview 5 9.2 Alternating umbrellas and umbrella extend 5 9.3 umbrella umbrella extended pitch ratio 6 9.4 Minimum distance between the umbrella 6 9.5 creepage distance and spacing 7 9.6 umbrella inclination 7 9.7 creepage factor 8 10 Reference Unified creepage distance (RUSCD) amendment 8 10.1 Fixed Reference Unified creepage distance (RUSCD) Calculation 8 10.2 altitude correction Ka 8 10.3 insulator diameter correction Kad 8 The minimum creepage distance of 11 finalized 9 12 experimental verification 9 Appendix A (informative) of this section with IEC /T S60815-3.2008 technical differences and their causes 10 Annex B (informative) contamination cause deterioration of composite insulators information 12 References 14 Figure 1 RUSCD relationship between the curve and the SPS grade 4 Figure 2 typical open umbrella 4 Figure 3 Typical alternately umbrella 5 Diagram 4 Kad and the average diameter and 8 icon Figure B.1 operating region, and the degree of contamination and USCD relationship (insulator length unchanged) 13

Foreword

GB/T 26218 "under filthy conditions Insulators selection and sizing" is divided into five sections. --- Part 1. Definitions, information and general principles; --- Part 2. AC system with porcelain and glass insulators; --- Part 3. composite insulators for ac systems; --- Part 4. DC system with porcelain and glass insulators; --- Part 5. DC system with composite insulators. This section GB/T 26218 Part 3. This section drafted in accordance with the rules of GB/T 1.1-2009 and GB/T 20000.2-2009 given. This section uses redrafted Law Amendment uses IEC /T S60815-3.2008 under "filthy conditions and selection Insulators Sizing Part 3. Polymer insulators for ac systems "(in English). Given our outdoor insulators under filthy conditions of use are basically silicone rubber composite insulators as the umbrella cover, and epoxy resin, EPDM and other materials as the number of insulators umbrella cover very few and the lack of operating experience, this part of IEC /T S60818-3.2008 name Name and scope have been modified only for dimethyl siloxane based silicone rubber umbrella sets of silicone rubber composite insulators, and deleted IEC /T S60815-3 in relation to non-silicone rubber insulators. This part of IEC /T S60815-3.2008 technical differences exist compared to the terms of these differences has been involved through its outer margin Vertical single line blank position (|) have been marked, the list given in Appendix A corresponding technical differences and their causes. This section and IEC /T S60815-3. compared to 2008, reg number changes as follows. --- 5.2.1 and 5.2.2 of the merger rewritten as 5.2; --- The suspension of paragraph 10 of Chapter rewrite 10.1, the original title of a strip extended; --- Number remaining clauses are identical. Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents. This part is proposed by the China Electrical Equipment Industrial Association. The insulators in part by the National Standardization Technical Committee (SAC/TC80) centralized. This section drafted by. China Electric Power Research Institute, Xi'an High Voltage Apparatus Research Institute Co., Ltd., State Grid Electric Power Research Institute, National Insulator arrester Quality Supervision and Inspection Center, Tsinghua University, Chongqing University, China Southern Power Grid Company EHV company, State Grid Corporation, China Power Engineering Consulting Group, East China Electric Power Design Institute, China Power Engineering Consulting Group, Central South Electric Power Design Institute, Dalian Insulator Group shares have Ltd., Guangzhou McLean Power Co., Ltd. Xiangfan State Grid composite insulator, Nantong Shenma Power Technology Co., Secretary, Suzhou Cichang Limited. The main drafters of this section. Fan Jianbin, Su Chih-yi, Yaojun Rui, Ying Yang Jian, Wei Peng, Liang Xi east PROCEEDINGS Yong, TRANSACTIONS OF THE ARMY Zhao Hui, Wang Shaowu, Michael, and had even born, Rengui Qing, Ouyang Xu Dan, Hong-Jun Yang, Ma Bin, Zhou Lu. High voltage insulators under filthy conditions of use Selection and sizing Part 3. composite insulators for ac systems

1 Scope and purpose

This section GB/T 26218 gives the specific characteristics of the insulator substantially in some filthy environment judging guidelines and principles. This section applies to high voltage AC system under filthy conditions determined by the size and selection of composite insulators. Of this section to CIGRE33.13TF01 [1] [2] as a base, we want in-depth study under filthy conditions insulator Performance Division Research staff can put the file as a useful supplement. This section does not involve the impact of snow and ice contamination insulator. Although CIGRE [3] which has been studied, but little information available, experience the difference Do not larger. The purpose of this section is. --- Through on-site contamination degree (SPS) is determined with reference to a unified specific creepage distance (RUSCD); --- Select the appropriate umbrella; --- Unified reference creepage distance (RUSCD) for altitude changes, insulator shape, size, installation location correction.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 2900.8-2009 Electrotechnical terminology insulator (IEC 60050-471.2007, IDT) GB/T 24622-2009 insulator surface wettability measurement guidelines (IEC /T S62073.2003, IDT) GB/T 26218.1-2010 filthy conditions under high pressure insulator selection and sizing - Part 1. Definitions, information and general Principles (IEC /T S60815-1.2008, MOD) 3 Terms, definitions and abbreviations 3.1 Terms and Definitions GB/T 2900.8-2009 and GB/T 26218.1-2010 and as defined in the following terms and definitions apply to this document. 3.1.1 Reference Unified creepage distance (RUSCD) referenceunifiedspecificcreepagedistance; RUSCD According to the part size, shape, location, etc. installation unified creepage distance initial value before correction, usually in mm/kV representation. 3.2 Acronyms The following abbreviations apply to this document. Creepage factor CF creepagefactor ESDD equivalentsaltdepositdensity ESDD HTM hydrophobicitytransfermaterial hydrophobic material migration

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 26218.3-2011_English be delivered?

Answer: Upon your order, we will start to translate GB/T 26218.3-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 26218.3-2011_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 26218.3-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.