US$544.00 ยท In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 25915.13-2022: Cleanrooms and associated controlled environments - Part 13: Cleaning of surfaces to achieve defined levels of cleanliness in terms of particle and chemical classifications Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 25915.13-2022 | English | 544 |
Add to Cart
|
5 days [Need to translate]
|
Cleanrooms and associated controlled environments - Part 13: Cleaning of surfaces to achieve defined levels of cleanliness in terms of particle and chemical classifications
| Valid |
GB/T 25915.13-2022
|
PDF similar to GB/T 25915.13-2022
Basic data Standard ID | GB/T 25915.13-2022 (GB/T25915.13-2022) | Description (Translated English) | Cleanrooms and associated controlled environments - Part 13: Cleaning of surfaces to achieve defined levels of cleanliness in terms of particle and chemical classifications | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | C70 | Classification of International Standard | 13.040.35 | Word Count Estimation | 30,367 | Date of Issue | 2022-12-30 | Date of Implementation | 2023-07-01 | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 25915.13-2022: Cleanrooms and associated controlled environments - Part 13: Cleaning of surfaces to achieve defined levels of cleanliness in terms of particle and chemical classifications
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 13.040.35
CCSC70
National Standards of People's Republic of China
Cleanrooms and related controlled environments
Part 13.Achieving particle and chemical cleanliness
required surface cleaning
(ISO 14644-13.2017, IDT)
Posted on 2022-12-30
2023-07-01 implementation
State Administration for Market Regulation
Released by the National Standardization Management Committee
table of contents
Preface I
Introduction II
1 Scope 1
2 Normative references 1
3 Terms and Definitions 2
4 General method 3
5 Object description 4
6 Cleanliness requirements 5
7 Determination of initial pollution level 5
8 Other requirements 6
9 Choice of cleaning method 6
10 Material Compatibility Check 7
11 Cleaning Validation 7
12 Measurement method 11
13 records 12
Appendix A (informative) Cleaning elements 13
Appendix B (informative) Cleaning method 14
Appendix C (informative) Compatibility of materials and cleaning agents 20
Appendix D (informative) cleanliness measurement 22
Reference 26
foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules for Standardization Documents"
drafting.
This document is part 13 of GB/T 25915 "Clean Room and Related Controlled Environment". GB/T 25915 has issued the following
part.
--- Part 1.Classification of air cleanliness by particle concentration;
--- Part 2.Monitoring of air particle concentration in clean rooms;
--- Part 3.Detection methods;
--- Part 4.Design, construction, start-up;
--- Part 5.Operation;
--- Part 6.Vocabulary;
--- Part 7.Isolation device (clean air hood, glove box, isolator, micro-environment);
--- Part 8.Classification of air cleanliness (ACC) grades by chemical concentration;
--- Part 9.Classification of surface cleanliness by particle concentration;
--- Part 10.Classification of surface cleanliness by chemical concentration;
--- Part 12.Technical requirements for monitoring the concentration of nanoparticles in the air;
--- Part 13.Surface cleaning to meet particle and chemical cleanliness requirements;
--- Part 14.Evaluation of equipment suitability by particle concentration;
--- Part 15.Evaluate the suitability of equipment and materials according to the concentration of gaseous chemicals.
This document is equivalent to ISO 14644-13.2017 "Clean rooms and related controlled environments - Part 13.Achieving particle and chemical cleanliness
Required Surface Cleaning".
The following minimal editorial changes have been made to this document.
---Corrected the step number error in 4.2, will "should start from step 1 to check the compatibility of the cleaning method with the material (step 6). Finally
After (step 7) method verification should be carried out" to "should start from step 1 to check the compatibility of the cleaning method with the material (step 6,
7). Finally (step 8) method validation should be performed. "
Please note that some contents of this document may refer to patents. The issuing agency of this document assumes no responsibility for identifying patents.
This document is proposed and managed by the National Standardization Technical Committee for Cleanrooms and Related Controlled Environments (SAC/TC319).
This document is drafted by. Shenzhen Lifeng Purification Engineering Co., Ltd., Wujiang Huayu Purification Equipment Co., Ltd., Zhongdian Jingtai Electronics Co., Ltd.
Cheng Co., Ltd., Suzhou Metrology and Testing Institute, Jiangsu Jiahe Clean Technology Co., Ltd., China Electronics System Engineering Fourth Construction Co., Ltd., Tian
University of Tianjin, China Electronics Engineering Design Institute Co., Ltd., China Electronics System Engineering Second Construction Co., Ltd., China Standardization Association, China Construction
Building Science Research Institute Co., Ltd., Building Safety Inspection and Testing Center Co., Ltd., Guangdong Clean Technology Industry Association, Shanghai Indoor Environmental Purification
Industry associations, China National Accreditation Center for Conformity Assessment, Beijing Zhongbang Xingye Technology Co., Ltd., Yantai Baoyuan Purification Co., Ltd., Shenzhen Ji
Long Clean Technology Co., Ltd., Jianghan University, Henan Shengchuan Purification Engineering Co., Ltd., Nanjing University of Technology, Guangdong Quantitative Testing Technology Co., Ltd.
Division, Anhui Tongyi Purification Technology Co., Ltd., Shenzhen Langao Clean Technology Co., Ltd.
The main drafters of this document. Shi Sujuan, Zhang Xiuchun, Sun Yucheng, Tong Guangcai, Li Jinping, Liu Junjie, Hao Yinbo, Zuo Zhongjie, Shi Xiaolei,
Feng Xin, Gao Zheng, Hu Maocong, Chen Siyuan, Zhou Bin, Huang Jihui, Han Hui, Yu Xiaobiao, Shao Sen, Liu Lu, Chang Jinxue, Wen Xiaohui, Yang Pengju, Shi Ting,
Liu Zhen, Zhang Xuan, Tong Najie, Liu Yong, Yang Yuntao.
Introduction
GB/T 25915 adopts the ISO 14644 series of international standards, and the settings of each part are consistent with the international standards. It is proposed to be composed of 15 parts
constitute.
--- Part 1.Classification of air cleanliness by particle concentration. The purpose is to differentiate the degree of particle contamination.
--- Part 2.Monitoring of air particle concentration in clean rooms. The purpose is to guide the monitoring of particle contamination to avoid possible contamination
risk.
--- Part 3.Detection method. The purpose is to guide the detection of various pollution and related environmental elements in the clean room.
--- Part 4.Design, construction, start-up. The purpose is to guide the design, construction and start-up of clean rooms.
--- Part 5.Operation. The purpose is to guide the operation of the clean room.
--- Part 6.Vocabulary. The purpose is to unify and standardize technical terms.
--- Part 7.Isolation device (clean air hood, glove box, isolator, micro-environment). The aim is to propose the basis for isolators for cleanrooms
This requirement.
--- Part 8.Classification of air cleanliness (ACC) by chemical concentration. The purpose is to distinguish the degree of air chemical pollution.
--- Part 9.Classification of surface cleanliness by particle concentration. The purpose is to differentiate the degree of surface particle contamination.
--- Part 10.Classification of surface cleanliness by chemical concentration. The purpose is to differentiate the degree of chemical contamination of the surface.
--- Part 12.Technical requirements for monitoring the concentration of nanoparticles in the air. The aim is to propose the detection of particle contamination at the nanoscale
Require.
--- Part 13.Surface cleaning to achieve particle and chemical cleanliness requirements. The purpose is to put forward the cleaning requirements for the surface of the clean room to
Avoid the risk of possible particle and chemical contamination.
--- Part 14.Assessment of equipment suitability by particle concentration. The purpose is to pass the relevant equipment that may generate particle contamination in the clean room
A test to determine the suitability of the device.
--- Part 15.Evaluate the suitability of equipment and materials according to the concentration of gaseous chemicals. The purpose is to make possible
Tests for gaseous chemical contamination in clean rooms to determine the suitability of equipment and materials.
--- Part 16.Improve the energy efficiency of clean rooms and air purification devices. The aim is to save energy consumption in clean room operation.
The term "surface" generally refers to the interface between two phases. Surface herein refers specifically to a solid surface. A "clean surface" is one or more types of pollution
(particle contamination, chemical contamination) controlled surfaces. Cleanliness grades are specified in ISO 14644-9 and ISO 14644-10.cleanliness
(Cleanliness class) depends on the cleaning method. This article is a guide for selecting a cleaning method to achieve a specified degree of cleanliness. When choosing a cleaning protocol to
Consider. surface condition, cleaning requirements, type of contamination, cleaning techniques, material compatibility, evaluation methods, etc. Most cleaning methods can be
When cleaning more than one type of contamination, it is necessary to develop a cleaning option that applies to both particle and chemical contamination.
common standard of approach.
Cleanrooms and related controlled environments
Part 13.Achieving particle and chemical cleanliness
required surface cleaning
1 Scope
This document provides guidance on the cleaning of cleanroom surfaces, equipment surfaces and material surfaces to achieve the required cleanliness. Surface references in this document
and all surfaces (exterior, interior).
This document provides Particle Concentration (SCP) and Surface Chemical Cleanliness (SCC) cleanliness for assessing Surface Cleanliness
The required cleaning methods, and the cleaning techniques that should be considered to achieve the specified cleanliness.
ISO 14644.9 and ISO 14644.10 give the suitability rate and related detection methods of cleaning technology.
This document contains the following general guidelines.
--- Surface target cleanliness level;
--- Applicability of the cleaning method;
--- Compatibility of the surface with the cleaning technology;
--- Evaluation of the suitability of the cleaning method.
This document does not cover the following.
--- Classification of cleaning methods;
---Products produced in clean rooms;
--- Specific cleaning methods associated with specific surfaces;
--- Detailed description of the cleaning mechanism, specific methods and procedures of various cleaning methods;
--- Detailed description of material properties;
--- Mechanism of surface damage by cleaning process and cleaning time;
--- Adhesion between the pollutant and the surface, and the adhesion process usually related to time and process;
---Other characteristics of particles, such as static electricity, ions, etc.;
---Chemical reaction of molecular pollutants with surfaces;
--- surface microorganisms;
--- radioactive contamination;
---health and safety;
---Environmental factors, such as. waste disposal, discharge, etc.;
--- Selection of statistical methods.
2 Normative references
The contents of the following documents constitute the essential provisions of this document through normative references in the text. Among them, dated references
For documents, only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to
this document.
ISO 14644-8 Clean rooms and related controlled environments Part 8.Air cleanliness (ACC) classes by chemical concentration
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 25915.13-2022_English be delivered?Answer: Upon your order, we will start to translate GB/T 25915.13-2022_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 25915.13-2022_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 25915.13-2022_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|