HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (11 Oct 2025)

GB/T 25915.14-2022 PDF English

US$305.00 · In stock · Download in 9 seconds
GB/T 25915.14-2022: Cleanrooms and associated controlled environments - Part 14: Assessment of suitability for use of equipment by airborne particle concentration
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
GB/T 25915.14-2022English305 Add to Cart 0-9 seconds. Auto-delivery Cleanrooms and associated controlled environments - Part 14: Assessment of suitability for use of equipment by airborne particle concentration Valid

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: GB/T 25915.14-2022
      

Similar standards

GB/T 25915.1   GB/T 25915.2   GB/T 25915.2   GB/T 25915.17   

GB/T 25915.14-2022: Cleanrooms and associated controlled environments - Part 14: Assessment of suitability for use of equipment by airborne particle concentration


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT25915.14-2022
GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 13.040.35 CCS C 70 GB/T 25915.14-2022 / ISO 14644-14:2016 Cleanrooms and associated controlled environments - Part 14: Assessment of suitability for use of equipment by airborne particle concentration (ISO 14644-14:2016, IDT) ISSUED ON: DECEMBER 30, 2022 IMPLEMENTED ON: JULY 01, 2023 Issued by: State Administration for Market Regulation; Standardization Administration of the People’s Republic of China.

Table of Contents

Foreword ... 3 Introduction ... 5 1 Scope ... 7 2 Normative references ... 7 3 Terms and definitions ... 8 4 General outline of the assessment ... 9 5 Visual examination ... 10 6 Assessment of suitability by airborne particle concentration measurements ... 11 7 Record ... 18 8 Statement on cleanroom suitability ... 21 Annex A (Informative) Example for data processing deriving from measurements .. 22 Annex B (Informative) Additional optional tests ... 26 Bibliography ... 29

Foreword

This document was drafted in accordance with the rules provided in GB/T 1.1-2020 Directives for Standardization - Part 1: Rules for the Structure and Drafting of Standardizing Documents. This document is Part 14 of GB/T 25915 Cleanrooms and associated controlled environments. The following parts have been issued for GB/T 25915: -- Part 1: Classification of air cleanliness by particle concentration; -- Part 2: Monitoring to provide evidence of cleanroom performance related to air cleanliness by particle concentration; -- Part 3: Test methods; -- Part 4: Design, construction and start-up; -- Part 5: Operations; -- Part 6: Vocabulary; -- Part 7: Separative devices (clean air hoods, gloveboxes, isolators and minienvironments); -- Part 8: Classification of air cleanliness by chemical concentration (ACC); -- Part 9: Classification of surface cleanliness by particle concentration; -- Part 10: Classification of surface cleanliness by chemical concentration; -- Part 12: Specifications for monitoring of air cleanliness by nanoscale particle concentration; -- Part 13: Cleaning of surfaces to achieve defined levels of cleanliness in terms of particle and chemical classifications; -- Part 14: Assessment of suitability for use of equipment by airborne particle concentration; -- Part 15: Assessment of suitability for use of equipment and materials by airborne chemical concentration. This document is identical to ISO 14644-14:2016 Cleanrooms and associated controlled environments - Part 14: Assessment of suitability for use of equipment by airborne particle concentration. Cleanrooms and associated controlled environments - Part 14: Assessment of suitability for use of equipment by airborne particle concentration

1 Scope

This document applies to the assessment of the suitability of equipment (e.g., machinery, measuring equipment, process equipment, components and tools) for use in cleanrooms and associated controlled environments. As specified in GB/T 25915.1, airborne particle sizes range from 0.1 μm to equal to or larger than 5 μm. The following items are not covered by this document: -- assessment of suitability with respect to biocontamination; -- testing for suitability of decontamination agents and techniques; -- cleanability of equipment and materials; -- requirements on design of equipment and selection of materials; -- physical properties of materials (e.g., electrostatic, thermal properties); -- optimizing performance of equipment for specific process applications; -- selection and use of statistical methods for testing; -- protocols and requirements for local safety regulations.

2 Normative references

The following documents, in whole or in part, are normatively referenced in this document and are indispensable to its application. For dated references, only the version corresponding to that date is applicable to this document; for undated references, the latest version (including all amendments) is applicable to this document. GB/T 25915.1-2021, Cleanrooms and associated controlled environments - Part 1: Classification of air cleanliness by particle concentration (ISO 14644-1:2015, MOD) Note: There is no technical difference between the referenced content of GB/T 25915.1-2021 and the referenced content of ISO 14644-1:2015. Note: Testing of equipment for ISO Class 1 suitability is accomplished in an ISO Class 1 environment. The test environment shall not contain any other particle sources than the equipment to be assessed to avoid influencing the measurement results. This can be achieved using unidirectional airflow. 6.2.6 Approximate identification of HPC location(s) For equipment with moving elements/components, there is frequently a significant variation in the concentration of particles generated between different zones of the equipment. The intention of the cleanroom suitability methodology is to include those zones that contain HPC(s) within the suitability assessment measurements. It is essential that moving elements/components, utilities, interfaces, etc., are included in this assessment. Note: The number of moving elements/components can influence the number of approximate HPC locations. Although safe sampling can impose sampling position limitations, the objective is to vary the distance and/or position of the sampling probe in order to identify the HPC location(s). The approximate identification shall be performed using a systematic scan of the equipment with a light scattering discrete airborne particle counter (LSAPC). The entire system including product spaces of the equipment should be scanned by the sampling probe. While the equipment is scanned using a sampling probe of the LSAPC, a correlation between its position and the HPC is acquired. Depending on the make/model of the LSAPC used, the feedback required to establish this correlation can use visual and/or acoustic means. The sample acquisition time shall be chosen to ensure that the location of the HPC(s) can be identified appropriately. Previously identified contamination sources (output of any pre-tests) should be included in this part of the assessment. The conclusions of the measurements undertaken for the approximate identification of particle sources are qualitative in nature. 6.2.7 Precise determination of HPC location(s) Following the approximate identification, a precise determination of HPC location(s) is carried out using a LSAPC assessing at least 28.3 L/min of air with a probe having an openness limited to 20 cm2. During this measurement stage, the geometrical position of the LSAPC sampling probe is adjusted to achieve the optimum sampling of the HPC location. Probe position shall be set and recorded. This is repeated for each HPC location identified under 6.2.6. ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of GB/T 25915.14-2022 be delivered?

Answer: The full copy PDF of English version of GB/T 25915.14-2022 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB/T 25915.14-2022_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 25915.14-2022_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- GB/T 25915.14-2022 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of GB/T 25915.14-2022?

A step-by-step guide to download PDF of GB/T 25915.14-2022_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB/T 25915.14-2022".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9