US$189.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 24565-2009: Monitoring and testing for energy saving of tunnel kiln Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 24565-2009 | English | 189 |
Add to Cart
|
3 days [Need to translate]
|
Monitoring and testing for energy saving of tunnel kiln
| Valid |
GB/T 24565-2009
|
PDF similar to GB/T 24565-2009
Basic data | Standard ID | GB/T 24565-2009 (GB/T24565-2009) | | Description (Translated English) | Monitoring and testing for energy saving of tunnel kiln | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | F01 | | Classification of International Standard | 27.010 | | Word Count Estimation | 8,824 | | Date of Issue | 2009-10-30 | | Date of Implementation | 2010-05-01 | | Quoted Standard | GB/T 4272 | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 12 of 2009 (No. 152 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the tunnel kiln energy monitoring program, monitoring methods and assessment indicators. This standard applies to coal, gas, oil -flame type and muffle -type production ceramics, bricks and refractory industrial tunnel kiln. |
GB/T 24565-2009: Monitoring and testing for energy saving of tunnel kiln---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Monitoring and testing for energy saving of tunnel kiln
ICS 27.010
F01
National Standards of People's Republic of China
Tunnel kiln energy monitoring
Posted 2009-10-30
2010-05-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
Appendix A of this standard is a normative appendix.
This standard by the National Standardization Technical Committee for Energy Management and focal points.
This standard was drafted. Tianjin energy monitoring four points, Tianjin Institute of Energy Technology, Industrial Furnace Co., Ltd. Tianjin Saiyo.
The main drafters of this standard. Shangke Wu, Jia Jun, Wangjing Liang, Zhu Tianli, Ren Changqing, Huoquan Lan, Zhang review, Wang Jinxiang, Liu Feng, Chen Shan,
Yang Ying, Chen Fang.
Tunnel kiln energy monitoring
1 Scope
This standard specifies the tunnel kiln energy monitoring program, monitoring methods and assessment indicators.
This standard applies to coal, gas, fuel type and open flame muffle type production of ceramic products, tiles and refractories industrial tunnel kiln.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 4272 General technical equipment and pipeline insulation
3 Terms and Definitions
The following terms and definitions apply to this standard.
3.1
The difference between surface temperature and ambient temperature tunnel kiln body.
4 tunnel kiln energy monitoring project
Check item 4.1
4.1.1 The kiln should be tight, complete, equipment and pipe insulation should be consistent with GB/T 4272 regulations.
4.1.2 Metering fully equipped, reasonable, and in the test cycle.
4.1.3 Exhaust systems, flue, chimney set reasonable work properly.
4.2 Test Project
4.2.1 exhaust gas temperature.
4.2.2 air factor.
4.2.3 Exhaust gas combustible components. CO, H2, CH4.
4.2.4 kiln surface temperature.
4.2.5 coal-ash carbon content.
5 tunnel kiln energy monitoring method
5.1 Conditions and Monitoring time
Monitoring should be carried out in the tunnel kiln production normal, steady state thermal conditions. Monitoring time not less than 2h.
5.2 Monitoring Instruments
Monitoring equipment should be used in good condition, the measurement range and resolution should be adapted to measure the project, its accuracy should not be less than shown in Table 1
Seek and test cycle. Instrument accuracy not less than the value specified in Table 1 of the new instrument, applicable to this standard.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 24565-2009_English be delivered?Answer: Upon your order, we will start to translate GB/T 24565-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 24565-2009_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 24565-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|