HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (20 Apr 2025)

GB/T 24431-2009 English PDF

Search result: GB/T 24431-2009
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 24431-2009English209 Add to Cart 3 days [Need to translate] Equipment and facilities in the prostheses and orthoses fitting units Valid GB/T 24431-2009


BASIC DATA
Standard ID GB/T 24431-2009 (GB/T24431-2009)
Description (Translated English) Equipment and facilities in the prosheses and orthoses fitting units
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard C45
Classification of International Standard 11.040.40
Word Count Estimation 9,947
Date of Issue 2009-09-30
Date of Implementation 2009-12-01
Drafting Organization China Rehabilitation Equipment Association
Administrative Organization National Standardization Technical Committee rehabilitation of persons with disabilities and special equipment
Regulation (derived from) National Standard Approval Announcement 2009 No.10 (Total No.150)
Proposing organization People's Republic of China Ministry of Civil Affairs
Issuing agency(ies) Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China
Summary This standard specifies the prosthetics and orthotics fitting venue institutions should have, facilities and equipment types and specifications. This standard applies to all types of institutions engaged in clinical prosthetic or orthotic device assembly. This standard does not apply to engage in orthopedic products parts, materials and general orthotics finished production or sales organization.


GB/T 24431-2009 Equipment and facilities in the prosheses and orthoses fitting units ICS 11.040.40 C45 National Standards of People's Republic of China Prosthetics, orthotics mechanism assembly facilities Posted 2009-09-30 2009-12-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of Contents Introduction Ⅲ Introduction Ⅳ 1 Scope 1 2 Normative references 1 3 Terms and definitions Court 4 2 5 2 facilities Use and management of equipment 4 6 Foreword The standard proposed by the People's Republic of China Ministry of Civil Affairs. This standard by the national rehabilitation and special equipment Standardization Technical Committee on Persons with Disabilities (SAC/TC148) centralized. This standard was drafted. China Rehabilitation Devices Association, prosthetic rehabilitation research center in Zhejiang Province, Beijing Kang Lubo orthopedic Co., Ruiha International (Beijing) orthopedic Trading Company, Beijing by Lucy rehabilitation engineering technology development center, Shenyang good Austrian orthopedic rehabilitation center. The main drafters of this standard. Cai Weiyi, Sun Gang, WANG Hai, Zhang Rui, Liu Qi, Xu Shuqiu. introduction This standard is to solve the prosthetics and orthotics clinical production and assembly facilities no standard mechanism, part of the production assembly facility sites Inadequate facilities and equipment, is not conducive to safeguarding the interests of the patient's illness or assistive devices to be installed in other physically disabled persons, affecting the industry continued Development of made. This standard is the basis of the investigation of the status of the domestic industry, the outpatient examination, take measurements type, model processing, vacuum forming, mechanical repair, Fit, function, and other special training facilities and equipment, according to the utility, the basic principles of universal norms of conduct in order to protect the patient physically disabled or related Legitimate rights and interests, to ensure that they receive rehabilitation services scientific, standardized, and guide the healthy and scientific development. To highlight about prosthetics and orthotics production and assembly purposes, GM's facilities and equipment, such as fire-fighting equipment and other facilities should be the national fire department Provisions with provisions not covered by this standard. Prosthetics, orthotics mechanism assembly facilities 1 Scope This standard specifies the prosthetics and orthotics assembly facility should have venues, facilities and equipment types and specifications. This standard applies to all types of institutions engaged in prosthetic or orthotic clinical assembly. This standard does not apply to products in the orthopedic components, materials and general orthotics finished products or sales. 2 Normative references The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 14191.1 Prosthetics and orthotics academic language - Part 1. Basic terminology external limb prostheses and external orthoses JGJ/50-2001 urban roads and buildings accessible design specifications 3 Terms and Definitions GB/T 14191.1 well established in the following terms and definitions apply to this standard. 3.1 For the reception or other injury, disease need to install assistive devices physically disabled patients and be functional disability or workplace inspections. 3.2 Or other injury to the patient need to install assistive devices physically disabled disease or physical conduct stump measurements taken plaster workplace. 3.3 Prosthetics, orthotics female or male trimming processing processing sites. 3.4 On the male composite material or a thermoplastic sheet formed by the process of working places evacuated. 3.5 Already molded prosthetic or orthotic device for grinding, shape modification, material cutting and processing of other places. 3.6 Prostheses or orthoses line, assembly, adjustment, modification of the workplace. 3.7 Conduct training prosthetic wear off, compensatory training, gait training and rehabilitation place. 3.8 Storing prosthetic or orthotic components needed for the production of plastic sheet, chemical materials room. ......

Similar standards: GB/T 39381.1   YY/T 1680   YY/T 1571   GB/T 24437   GB/T 24432