US$799.00 · In stock Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 21429-2008: Composite insulators -- Hollow insulators for use in outdoor and indoor electrical equipment -- Definitions, test methods, acceptance criteria and design recommendations Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 21429-2008 | English | 799 |
Add to Cart
|
6 days [Need to translate]
|
Composite insulators -- Hollow insulators for use in outdoor and indoor electrical equipment -- Definitions, test methods, acceptance criteria and design recommendations
| Valid |
GB/T 21429-2008
|
PDF similar to GB/T 21429-2008
Basic data | Standard ID | GB/T 21429-2008 (GB/T21429-2008) | | Description (Translated English) | Composite insulators -- Hollow insulators for use in outdoor and indoor electrical equipment -- Definitions, test methods, acceptance criteria and design recommendations | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K48 | | Classification of International Standard | 29.080.10 | | Word Count Estimation | 36,371 | | Date of Issue | 2008-01-22 | | Date of Implementation | 2008-09-01 | | Quoted Standard | GB/T 1182-1996; GB 1984-2003; GB/T 4585-2004; GB 8287.1-1998; GB/T 11020-1989; GB/T 11022-1999; GB/T 16927.1-1997; GB/T 19519-2004; IEC 60660-1999; IEC 60068-2-17-1994; IEC 60865-1995; IEC 60932-1988; IEC 61166-1993; IEC 62155-2003; ISO 3452-1984 | | Adopted Standard | IEC 61462-1998, MOD | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 2, 2008 (No. 115 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard applies to the production of a resin -impregnated fiber pipe insulation to withstand the load, the elastic material and the insulating tube umbrella cover both ends of the hollow metal accessories constitute composite insulators. Defined in this standard insulator for internal pressure or without pressure two cases. They are used for rated voltages above 1000V, frequency AC voltage is not higher than 100Hz run indoor or outdoor electrical equipment or the rated voltage above 1500V DC devices. The purpose of this standard are: definition of the terms used, provides test methods, required acceptance criteria. This standard does not specify the type test, or the impact of pollution test voltage or frequency voltage, because not withstand voltage insulators own characteristics, but eventually became one of its components insulator electrical device characteristics. |
GB/T 21429-2008: Composite insulators -- Hollow insulators for use in outdoor and indoor electrical equipment -- Definitions, test methods, acceptance criteria and design recommendations ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Composite insulators-Hollow insulators for use in outdoor and indoor electrical equipment. Definitions, test methods, acciptance criteria and design recommendations
ICS 29.080.10
K48
National Standards of People's Republic of China
Outdoor and indoor electrical equipment hollow composite insulators
Definitions, test methods, acceptance criteria and design recommendations
(IEC 61462.1998, MOD)
Posted 2008-01-22
2008-09-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
Introduction Ⅳ
1 Scope 1
2 Normative references 1
3 Terms and definitions 2
Relations between the mechanical load of each 4 4
4.1 Insulator external load 4
4.2 Pressure 4
5 signs 4
Category 6 Test 4
6.1 Test Design 4
5 6.2 Type test
6.3 Sampling Test 5
6.4-by-5 \u200b\u200btest
7 Design Experiment 5
7.1 General 5
Test 7.2 interface and end fitting connecting region 5
7.3 umbrella cover material testing 8
7.4 Test materials (water diffusion test) 11
8 Type tests (mechanical tests only) 11
8.1 General 11
8.2 test 13
8.3 Prepare the test sample 13
8.4 Test Procedure 14
8.5 Acceptance criteria 15
9 sampling test 15
9.1 Insulator selection and number 15
9.2 Test 15
15 9.3 Dimensional inspection
9.4 Mechanical tests 16
9.5 end fitting and insulator interface test suites umbrella 16
9.6 Acceptance criteria 16
Repeat the test procedure 16 9.7
10-by-17 test
10.1 General 17
10.2 Visual inspection 17
10.3-by-17 pressure test
10.4-by-17 Mechanical tests
10.5-by-17 seal test
10.6 Materials Test 17
11 File 18
Appendix A (normative) shape and position tolerances 19
General recommendations Appendix B (informative) design and construction of 21
In Appendix C (informative) insulator tube by the internal pressure and (or) caused reversible bending load and irreversible strain limit
25 determination
Annex D (informative) This standard and IEC 61462.1998 technical differences and their reasons 27
Annex E (informative) of the Standard Terms and IEC 61462.1998 clause controls 28
Foreword
This revised standard adopts IEC 61462.1998 "Outdoor and indoor electrical equipment hollow insulator definitions, test methods composite, receiving
Guidelines and design recommendations. "
This standard and IEC 61462.1998 "indoors and outdoors electrical equipment hollow composite insulators definitions, test methods and acceptance criteria
Design recommendations, "the technical differences between a single vertical line (|) in which they are involved in the provision of margin identity. In the informative Appendix D
It gives a list of the technical differences and the reasons for the reference. For ease of comparison, the data are listed in Appendix E of the Standard Terms and Conditions
1998 List of control provisions. with IEC 61462.
Compared with its increase of a trial.
--- Design experiments umbrella cover material increased resistance to tracking and erosion tests, mainly on account of the present situation of production and operation
Claim.
For ease of use, this standard also made the following editorial changes.
a) "this International Standard" be replaced by "this standard";
b) use a decimal point instead of a decimal comma ",". ",";
c) Remove the preface to international standards.
Appendix A of this standard is a normative appendix, Appendix B, Appendix C, Appendix D, Appendix E is informative appendix.
The standard proposed by China Electrical Equipment Industrial Association, the National Standardization Technical Committee under the jurisdiction of the insulator.
This standard was drafted. Xi'an Ceramic Institute, China Electric Power Research Institute, Wuhan High Voltage Research Institute, Fujian Electric Power Company, Nantong
City of God Ma Power Technology Co., Ltd., the high level Group Limited, Shanghai MWB Transformer Co., Ltd., Jiangsu Jiuding New Material Co. Shares
Company, Beijing Pan Am Mine Technology Co., Ltd.
The main drafters of this standard. Party town flat, Liu Yansheng, Peter Woo, Asia, Zhang Junfeng, Peng Wei, Li Xi education, Li Ting, Ma Bin, Xu satellite, Shi Xuelian,
Jiang Hu, Sun Wen Feng.
This standard was first formulated.
Introduction
Hollow composite insulators made of an elastic protective umbrella cover to withstand mechanical loads and insulating tubes, this load transfer from the metal attachment
Insulating tube. Despite these common features, materials and structures used by different manufacturers used may be different.
Although the hollow composite insulators have been used for various purposes, but these insulators on determining the size and lack of experience are still experimental.
1 Scope
This standard applies to the production of resin-impregnated fibers bear the load of the insulating tube, the elastic material (such as silicon rubber or ethylene propylene rubber) Production
The umbrella cover (outside the insulating tube) and metal accessories insulating tube constituting both ends of the hollow composite insulator (hereinafter referred to as "insulators"). this
Insulator defined in the standard for compression of internal pressurization or both. They are used for rated voltages higher than 1000V, the frequency is not high
AC voltage at 100Hz run outdoors or indoor electrical equipment or the rated voltage higher than 1500V DC device.
The purpose of the standard is.
--- Definitions of the terms used;
--- Specified test methods;
--- Specified acceptance criteria.
This standard does not specify the type of test or contamination test impulse voltage or frequency voltage, because the withstand voltage insulator not own characteristics,
Instead insulator eventually became a member of the characteristics of electrical equipment.
Note 1. The internal pressure is the persistent gas pressure greater than 0.05MPa (0.5bar) gauge. The gas may be dry air or an inert gas, such as sulfur hexafluoride, nitrogen
Or a mixture of these gases.
Note 2. There is no internal pressure refers to a gas or liquid pressure less than or equal to 0.05MPa (0.5bar) gauge. Hydrostatic pressure exceeds 0.05MPa not negotiable
The same test procedure.
Note 3. The insulator is generally used in electrical equipment in the following (but not limited to).
a) the circuit breaker;
b) load switch;
c) isolation switch;
d) grounding switch;
e) transformers and power transformers;
f) casing.
Related equipment Commission may prescribe additional tests.
2 Normative references
The following documents contain provisions reference and become the standard terms of this standard. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents, undated reference documents, the latest versions apply to this standard.
GB/T 1182-1996 Geometrical tolerancing - Generalities, definitions, symbols, indications on drawings (eqv ISO 1101.1996)
GB 1984-2003 high voltage AC circuit breaker (IEC 62271-100.2001, MOD)
GB/T 4585-2004 high-voltage insulators for ac systems - Artificial pollution tests (IEC 60507.1991, IDT)
GB/T 8287.1-1998 High voltage post insulators - Part 1. Technical conditions (neqIEC 60168.1994)
GB/T 11020-1989 Determination of solid electrical insulating materials test method after combustion properties of the source of ignition is exposed
(Eqv IEC 60707. 1981)
GB/T 11022-1999 high-voltage switchgear and control equipment standard common technical requirements (eqv IEC 60694.1996)
GB/T 16927.1-1997 high voltage test techniques Part 1. General test requirements (eqv IEC 60060-1. 1989)
Above 1000V ac overhead lines with composite insulators definitions, test methods GB/T 19519-2004 and nominal
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 21429-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 21429-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 21429-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 21429-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|