US$259.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 21421.2-2014: Composite string insulator units for overhead lines with a nominal voltage greater than 1 000V -- Part 2: Dimensional and characteristics Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 21421.2-2014 | English | 259 |
Add to Cart
|
3 days [Need to translate]
|
Composite string insulator units for overhead lines with a nominal voltage greater than 1 000V -- Part 2: Dimensional and characteristics
| Valid |
GB/T 21421.2-2014
|
PDF similar to GB/T 21421.2-2014
Basic data Standard ID | GB/T 21421.2-2014 (GB/T21421.2-2014) | Description (Translated English) | Composite string insulator units for overhead lines with a nominal voltage greater than 1 000V -- Part 2: Dimensional and characteristics | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | K48 | Classification of International Standard | 29.080.10 | Word Count Estimation | 11,195 | Date of Issue | 7/24/2014 | Date of Implementation | 1/22/2015 | Older Standard (superseded by this standard) | GB/T 20876.2-2007 | Quoted Standard | GB 311.1-2012; GB/T 2900.8-2009; GB/T 4056-2008; GB/T 19519-2014; GB/T 21421.1-2008; GB/T 22079-2008; GB/T 25317-2010; GB/T 26218.1-2010; GB/T 26218.3-2011; JB/T 9683-2012 | Adopted Standard | IEC 61466-2-2002, MOD | Regulation (derived from) | National Standards Bulletin No. 19, 2014 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | Summary | This standard specifies the overhead lines and overhanging tension composite insulator strings element (hereinafter referred to as insulator) size, mechanical and electrical characteristics. This standard applies to nominal voltage greater than 1 000 V, f |
GB/T 21421.2-2014: Composite string insulator units for overhead lines with a nominal voltage greater than 1 000V -- Part 2: Dimensional and characteristics ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Composite string insulator units for overhead lines with a nominal voltage greater than 1 000V Part 2. Dimensional and characteristics
ICS 29.080.10
K48
National Standards of People's Republic of China
Replacing GB/T 20876.2-2007
Higher than 1000V nominal voltage overhead lines with a composite
String insulator Part 2. Dimensions and characteristics
greaterthan1000V-Part 2. Dimensionsandcharacteristics
(IEC 61466-2.2002Compositestringinsulatorunitsforoverheadlineswith
anominalvoltagegreaterthan1000V-Part 2. Dimensionaland
electricalcharacteristics, MOD)
Issued on. 2015-01-22 2014-07-24 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 Model 2
5 Dimensions and characteristics 2
5.1 Size 2
5.2 Mechanical properties 2
5.3 Electrical characteristics 2
Characteristic values \u200b\u200bof the insulator 2 6
7 coupled insulator mark 4
8 5 field control and protection devices
Appendix A (informative) of this section with IEC 61466-2.2002 reg control number 6
1 earrings shaped coupling structure 4
Table 1. The property values \u200b\u200bof the insulator 3
Table 2 insulator join numeral 4
Table 3 earrings shaped coupling size 5
Table A.1 This section of IEC 61466-2.2002 Chapter 6 Control Article ID
Foreword
GB/T 21421 "nominal voltage above 1000V overhead lines Composite string insulator element" is divided into two parts.
--- Part 1. Standard strength classes and end fittings;
--- Part 2. Dimensions and characteristics.
This section GB/T 21421 Part 2.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This Part replaces GB/T 20876.2-2007 "greater than 1000V nominal voltage overhead lines with a suspension element of composite insulators
Part 2. Dimensional and electrical characteristics ", compared with the GB/T 20876.2-2007, in addition to editorial changes and technological changes outside the following main reasons.
--- GB/T 20876.2-2007 Chapter 3, "mechanical and dimensional characteristics," Chapter 4, "Electrical Characteristics" and Chapter 7, "tolerance" belong
Characteristics section insulator string element, this section will merge to Chapter 5; identification string insulator element does not belong in this section
Capacity, and thus remove the GB/T 20876.2-2007 of Chapter 6;
--- Order and GB/T 21421 Part 1 corresponds, is consistent with the IEC and the corresponding text, this section renumbered
GB/T 21421.2;
Name --- this section was revised to "higher than 1000V nominal voltage overhead lines Composite string insulator units - Part 2. Size
Inch and Characteristics ";
--- Scope of this section from a predetermined mechanical load 40kN ~ 400kN modified to 40kN ~ 530 (550) kN, standard lightning impulse
Strike withstand voltage level and below to extend from 2700kV 3100kV and below;
--- Added "Chapter 3 Terms and definitions";
--- Establishment method according to JB/T 9683-2012 lists the basic model of the insulator;
--- To meet the GB/T 26218.1-2010 provisions of five unified creepage distance classification, characteristics table deleted the minimum creepage distance,
Chapter 5 adds "insulator creepage distance rating in accordance with the unified GB/T 26218.1-2010 Table I.1 specified creepage
Distance determination, "the statement, delete the GB/T 20876.2-2007 Appendix A." Information about the creepage distance ";
--- As one of the radio disturbance characteristics electrical characteristics of the insulator, and its value agreement by both parties;
--- Given the GB/T 21421.1-2008 earrings shaped table joins and table D.1 1 can not meet the needs of this part of the increase or repair
After the change the content to be included in Tables 2 and 3 of this section of the text;
--- For ease of understanding, increase earrings shaped coupling structure illustrated;
--- Remove Appendix B;
For the same reason --- standard lightning impulse withstand voltage levels may correspond to the maximum operating voltage of several systems, in order to avoid the resulting induced
Solutions difficulty, remove the informative Appendix C.
This section uses redrafted law revision using IEC 61466-2.2002 "nominal voltage above 1000V overhead lines with a composite insulation
Part 2 substring elements. size and characteristics. "
This section and the IEC 61466-2.2002, compared with the main technical differences are as follows, and a single vertical line in which they are involved in terms of page
Margin identity.
--- Size characteristics, "the maximum diameter of the insulating member" with "maximum nominal diameter insulating member";
--- Size characteristics, an increase of about "tolerance" requirement;
--- Consider the large number of our products with 400kN and 530kN and 550kN 420kN respectively actual use of the product evaluation,
Respectively after a predetermined level of mechanical load 400kN and 530kN and 420kN listed in parentheses 550kN level;
--- Standard lightning impulse voltage reference GB 311.1-2012 included;
--- Table 1, because the narrative already expressed, remove the mechanical strength class and the minimum creepage distance columns; adds standard lightning
Impulse withstand voltage 1050kV above the line.
IEC 61466-2.2002 Chapter 3, "Mechanical and dimensional characteristics," Chapter 4, "Electrical Characteristics" and Chapter 7, "tolerance" belong insulator
Characteristics partial string element, this section will merge to Chapter 5; identification string insulator element does not belong to the contents of this standard, and thus deleted
IEC 61466-2.2002 Chapter 6; For ease of comparison, the increase in Appendix A, this section lists the reg number and IEC 61466-2.2002
Reg number control list.
This part is proposed by the China Electrical Equipment Industrial Association.
The insulators in part by the National Standardization Technical Committee (SAC/TC80) centralized.
This part mainly drafted by. Xi'an High Voltage Apparatus Research Institute Co., Ltd., China Electric Power Research Institute, the National Insulator arrester
Is Quality Supervision and Inspection Center, the Guangdong Power Grid Corporation, Rugao City Health Line Equipment Co., Ltd. Guangzhou Power McLean, Xinjiang
New Energy Tinian Electrical Insulation Materials Co., Dalian Insulator Group Co., Ltd., Chongqing University, China Power Engineering Consulting Group Corporation.
Participated in the drafting of this section. Dongguan City Electric Energy Co., Ltd., State Grid Xiangyang Composite Insulator Co., Ltd., Nanjing Electric
Gas (Group) Co., Ltd. Xi'an Electric high voltage bushing, Wenzhou Yi Kun Electric Co., Ltd., China Railway Eryuan Engineering Group Co.,
Ltd., build power plant in Baoding, Cangzhou Hualing Electric Co., Ltd., Zhengzhou Xianghe Group Electric Equipment Co., Ltd., Zibo Taekwang power device
Plant material, Chint Electric Co., Ltd.
The main drafters of this section. Party town flat, Yao Junrui, TRANSACTIONS OF THE Zhang Rui, Zhou Huamin, Zheng Da Sheng, Wei Peng, Yun-Peng Wang, Ouyang Xu Dan,
Qi Dong Bao, high Degang, Zhang Jin, LEE double.
The drafters of some of the participants. Zhao Tianren, Wu Zhaofeng, Gurui Yun, Hou Jianfeng, Jin Qiang, Yu Mingxuan, Tang Wei, Liu blue, Bai Shujie, Guohui Hao,
Teng Guoli, Zhang Shuliang.
This part of the standard replaces the previous editions are.
--- GB/T 20876.2-2007.
Higher than 1000V nominal voltage overhead lines with a composite
String insulator Part 2. Dimensions and characteristics
1 Scope
This section GB/T 21421 specifies the string composite insulators for overhead lines and overhanging elements Tension (hereinafter referred to as insulator) ruler
Inch, mechanical and electrical properties.
This section applies to a nominal voltage above 1000V, frequency not exceeding 100Hz ac overhead lines with insulators.
This section also applies to insulators power substation or traction lines use similar structures.
This section applies to the coupling structure according to GB/T 21421.1-2008 Insulators.
GB/T 19519-2014 given general definitions and test methods.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB 311.1-2012 insulation coordination - Part 1. Definitions, principles and rules (IEC 60071-1.2006, MOD)
GB/T 2900.8-2009 Electrotechnical terminology insulator (IEC 60050-471.2007, IDT)
GB/T 4056-2008 insulator ball and socket connection string element size (IEC 60120. 1984, IDT)
GB/T 19519-2014 Insulators for overhead lines nominal voltage above 1000V ac systems Suspension and tension composite insulation
Sub-definitions, test methods and acceptance criteria (IEC 61109.2008, MOD)
GB/T 21421.1-2008 higher than 1000V nominal voltage overhead lines Composite string insulator units - Part 1. Standard Strong
Grade and end fittings (IEC 61466-1.1997, IDT)
GB/T 22079-2008 nominal voltage greater than 1000V indoor and outdoor use polymer insulators General definitions, test side
Method and acceptance criteria (IEC 62217.2005, MOD)
GB/T 25317-2010/IEC 60471. 1977 string insulator groove connection size
By GB/T 26218.1-2010 Insulators filthy conditions selection and sizing - Part 1. Definitions, information
And general principles (IEC /T S60815-1.2008, MOD)
By GB/T 26218.3-2011 Insulators filthy conditions selection and sizing Part 3. Communication systems
Composite insulators (IEC /T S60815-3.2008, MOD)
JB/T 9683-2012 insulator Model methodology
3 Terms and Definitions
GB/T 2900.8-2009, GB/T 22079-2008, GB/T 19519-2014, JB/T 9683-2012 defined terms and definitions
Meaning applicable to this document.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 21421.2-2014_English be delivered?Answer: Upon your order, we will start to translate GB/T 21421.2-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 21421.2-2014_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 21421.2-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|