HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (15 Jun 2025)

English GB/T 20219-2015 PDF (GB/T 20219-2006: Older version)

Search result: GB/T 20219-2015 (GB/T 20219-2006 Older version)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 20219-2015English209 Add to Cart 3 days [Need to translate] Rigid cellular plastics-spray-applied polyurethane foam for thermal insulation Valid GB/T 20219-2015
GB/T 20219-2006English399 Add to Cart 3 days [Need to translate] Spray-applied rigid polyurethane cellular plastics Obsolete GB/T 20219-2006


BASIC DATA
Standard ID GB/T 20219-2015 (GB/T20219-2015)
Description (Translated English) Rigid cellular plastics-spray-applied polyurethane foam for thermal insulation
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard G32
Classification of International Standard 83.100
Word Count Estimation 10,171
Date of Issue 2015-06-02
Date of Implementation 2016-01-01
Older Standard (superseded by this standard) GB/T 20219-2006
Quoted Standard GB/T 2918-1998; GB/T 6343-2009; GB/T 8810-2005; GB/T 8811-2008; GB/T 8813-2008; GB/T 9641-1988; GB/T 10294-2008; GB/T 10295-2008; GB/T 10799-2008; GB/T 21332-2008
Regulation (derived from) National Standard Announcement 2015 No.19
Issuing agency(ies) Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China
Summary This Standard specifies the thermal insulation spray rigid polyurethane foam of classification, requirements, test methods and inspection rules. This Standard applies to buildings or buildings for thermal insulation, rigid polyurethane spray a service temperature range of 60��C to 80��C foam. This Standard does not apply to single-component polyurethane foam material.


GB/T 20219-2015 Rigid cellular plastics-spray-applied polyurethane foam for thermal insulation ICS 83.100 G32 National Standards of People's Republic of China Replacing GB/T 20219-2006 Thermal insulation spray rigid polyurethane foam Issued on. 2015-06-02 2016-01-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Foreword This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard replaces GB/T 20219-2006 "spray rigid polyurethane foam." Compared with GB/T 20219-2006, in addition to editing Modifications outside the main technical changes are as follows. --- Amend the foreword, scope and normative references; --- Modify the product classification and methods from the original class Ⅰ, Ⅱ class modify ⅠA, ⅠB, ⅠC, ⅡA, ⅡB five categories (see Chapter 3, Chapter 4 of the 2006 edition); --- Increasing the apparent core density, tensile strength, water absorption three performance testing requirements (see 4.1); --- Modify the test requirements for dimensional stability indicators (see Table 2, 2006 edition of the Table 1); --- Modify the "initial conditions at 23 ℃ thermal conductivity" (see Table 2, 2006 edition of the Table 1); --- Modify the "water vapor permeability value" (see Table 2, 2006 edition of the Table 1); --- Delete the words "at 10 ℃ thermal conductivity" requirement (see the 2006 edition of the Table 1); --- Deleted "80 ℃ and 48h after pressure 20kPa compressive creep" (see the 2006 edition of the Table 1); --- Remove the "Test Report" (see the 2006 edition of Chapter 8); --- Modify the "Inspection Rules" (see Chapter 6, Chapter 7, 2006 edition). The standard proposed by China National Light Industry Council. This standard by the National Plastics Standardization Technical Committee (SAC/TC48) centralized. This standard was drafted. a Norwich Shandong New Materials Co., Ltd., Beijing Technology and Business University, Nanjing Red Polaroid Corp., Langfang City, Laguna Bao Polyurethane Co., Ltd., Jiangsu Institute of Chemical Co., Ltd. The main drafters of this standard. Industry Xu Feng, Chen Qian, Vivaldi, ROADS, Wu Hao. Thermal insulation spray rigid polyurethane foam 1 Scope This standard specifies thermal insulation spray rigid polyurethane foam classification, requirements, test methods and inspection rules. This standard applies to buildings or buildings for thermal insulation, spray rigid polyurethane foam service temperature range of -60 ℃ to 80 ℃ plastic. This standard does not apply to single-component polyurethane foam material. 2 Normative references The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 2918-1998 plastic sample conditioning and testing of the standard environment GB/T 6343-2009 foam and rubber Determination of apparent density Determination of GB/T 8810-2005 rigid foam water absorption GB/T 8811-2008 rigid foam dimensional stability test methods Measuring performance GB/T 8813-2008 rigid foam compression Performance test method GB/T 9641-1988 rigid foam stretch GB/T 10294-2008 steady insulation resistance and related properties - Guarded hot plate method GB/T 10295-2008 steady-state thermal resistance and insulation related properties - Heat flow meter method Determination of GB/T 10799-2008 rigid foam volume percentage of open and closed cells GB/T 21332-2008 Determination of rigid foam water vapor transmission properties Category 3 Products in accordance with the type of blowing agent, whether bearer, closed-cell foam open state is divided into ⅠA, ⅠB, ⅠC, ⅡA, ⅡB five categories (Table 1). Table 1 classification Categories open closed cell foaming agent carrying instructions ⅠA fluorocarbon closed-cell non-bearing It may not be exposed to the environment, the only self-supporting foam, such as for walls, roofs or Similar place insulation ⅠB The reaction of water with isocyanate Carbon dioxide generated Non-bearing semi-closed cells It may not be exposed to the environment, the only self-supporting foam, such as for walls, roofs or Similar place insulation ⅠC The reaction of water with isocyanate Carbon dioxide generated Opening non-bearing It may not be exposed to the environment, the only self-supporting foam, such as for walls, roofs or Similar place insulation ⅡA fluorocarbon obturator limited bearer It may be exposed or not exposed to the environment, such as a person can carry stampede deck, etc. Occasions, you may experience warming or compression creep, etc. ⅡB The reaction of water with isocyanate Carbon dioxide generated A limited bearing obturator It may be exposed or not exposed to the environment, such as a person can carry stampede deck, etc. Occasions, you may experience warming or compression creep, etc. ......

Similar standards: GB/T 25254   GB/T 15593   GB/T 17931   GB/T 32366   GB/T 40006.11