US$259.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 19638.2-2014: Lead-acid batteries for stationary valve-regulated -- Part 2: Kinds of products and specification Status: Valid GB/T 19638.2: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 19638.2-2014 | English | 259 |
Add to Cart
|
3 days [Need to translate]
|
Lead-acid batteries for stationary valve-regulated -- Part 2: Kinds of products and specification
| Valid |
GB/T 19638.2-2014
|
| GB/T 19638.2-2005 | English | 719 |
Add to Cart
|
5 days [Need to translate]
|
Fixed type VRLA battery
| Obsolete |
GB/T 19638.2-2005
|
PDF similar to GB/T 19638.2-2014
Basic data | Standard ID | GB/T 19638.2-2014 (GB/T19638.2-2014) | | Description (Translated English) | Lead-acid batteries for stationary valve-regulated -- Part 2: Kinds of products and specification | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K84 | | Classification of International Standard | 29.220.20 | | Word Count Estimation | 11,156 | | Date of Issue | 6/24/2014 | | Date of Implementation | 1/22/2015 | | Quoted Standard | JB/T 2599 | | Regulation (derived from) | National Standards Bulletin No. 14 of 2014 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This Standard specifies the fixed type VRLA (hereinafter referred to as the battery) model preparation, shape and size of the structure, terminal location, connection. This section applies in the rest of the place, and combined with the use of fixed equip |
GB/T 19638.2-2014: Lead-acid batteries for stationary valve-regulated -- Part 2: Kinds of products and specification ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Lead-acid batteries for stationary valve-regulated Part 2. Kinds of products and specification
ICS 29.220.20
K84
National Standards of People's Republic of China
Fixed type VRLA
Part 2. Product varieties and specifications
Part 2. Kindsofproductsandspecification
Issued on. 2014-06-24
2015-01-22 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
GB/T 19638 "Fixed type VRLA batteries" is divided into two parts.
--- Part 1. Technical conditions;
--- Part 2. product varieties and specifications.
This section GB/T 19638 Part 2.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This part is proposed by the China Electrical Equipment Industrial Association.
The lead-acid batteries in part by the National Standardization Technical Committee (SAC/TC69) centralized.
This part mainly drafted by. Leoch Battery Co., Ltd. Jiangsu double Deng Group Co., Ltd., Shandong Sacred Sun Power Company Limited
Secretary, Shenyang Institute of batteries, Harbin Guangyu Battery Co., Ltd., Shaoxing Meeting with the Battery Co., Zhejiang Wolong Electric Group
Beacon Power Limited, Wah Fu Jiangsu New Energy Storage Technology Co., Ltd., Hunan Fengri Power Electric Co., Ltd. Fujian Hua Min
Power Co., AMD Power Co., Ltd., days to Battery Group Co., Ltd., Jiangsu Su in Battery Technology Development Co., Ltd., Beijing
Force Standard Technology Co., Ltd, Changxing County, battery industry associations, national light electric vehicles and battery Product Quality Supervision and Inspection Center, Taizhou
City of Quality and Technical Supervision and Testing Institute, Zhejiang green power supply product quality inspection center.
Participated in the drafting of this section. Jiang Su Chaowei Power Co., Jester Zhejiang Electric Co., Ltd., Zhejiang Jiang Jujiang Power Manufacturing Co.
The company, Henan AMD Power Co., Ltd. Zhejiang Changxing Power Co., Ltd. Golden Sun, Huzhou long wide Haotian Power Co., Ltd. Changxing into the public electricity
Source Co., Ltd. Anhui eternal power, prestige Jiangxi Power Energy Technology Co., Ltd.
The main drafters of this section. Xie Shuang, Dong Jie, Xue Yu, Ruan Li, Yang Baofeng, Zhouqing Shen, Zhu Wenwu, Zhu Weimin, Li Lihua, Huang Yi, Xing Kai,
Huang Jianguo, Yang Xinxin, Yang Yuanling, Shen Restoration, Liu Ning, Zhaohai Min, Zang Ning.
The drafters of some of the participants. the mother Jianping. EDGE Li Qin slope, firewood into mine, open subtlety, holding Shen Di, Qian Shun-wing, Wurong Liang, Xu years.
Fixed type VRLA
Part 2. Product varieties and specifications
1 Scope
This section GB/T 19638 specifies the fixed-type VRLA batteries (hereinafter referred to as a battery) the model designation, shape structure
And size, the location of terminals, connections.
This section applies to and in conjunction with the fixed equipment in stationary places together using float or fixed in the battery compartment to pass
Letter, switching equipment, power, emergency power and uninterruptible power supply or a similar use of all fixed-type VRLA batteries (hereinafter referred to as the accumulator
Batteries) and batteries. Sulfuric acid electrolyte in the battery is not flowing, or adsorbed on the pore structure between the electrodes or in colloidal form.
This section does not apply to start with, and general storage use lead-acid batteries and batteries.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
JB/T 2599 lead-acid battery name, model designation and naming approach
3 model designation
Battery type should be consistent with the preparation of JB/T 2599 requirements. Specifically. Product type Chinese characters "solid" first capital letter of the alphabet
"G" indicates. Figure 1 details name.
6-
The number of single cells in series (a single battery omitted)
Fixed
F-
VRLA
10 hours rated capacity, Ah
Figure 1 a schematic model name
Example. The rated capacity of six cells in series for fixed-valve-100Ah battery model named 6-GF-100.
4 shape and size structure
Battery shape structure shown in Figure 2, Figure 3, specific dimensions shown in Table 1, Table 2.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 19638.2-2014_English be delivered?Answer: Upon your order, we will start to translate GB/T 19638.2-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 19638.2-2014_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 19638.2-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 19638.2-2014?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 19638.2-2014 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|