GB/T 19638.1-2014: Lead-acid batteries for stationary valve-regulated -- Part 1: Technical requirements
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 19638.1-2014English529 Add to Cart 4 days [Need to translate] Lead-acid batteries for stationary valve-regulated -- Part 1: Technical requirements Valid GB/T 19638.1-2014

PDF similar to GB/T 19638.1-2014


Standard similar to GB/T 19638.1-2014

GB/T 5008.3   GB/T 32620.2   GB/T 22199   GB/T 23638   GB/T 19639.2   GB/T 19638.2   

Basic data

Standard ID GB/T 19638.1-2014 (GB/T19638.1-2014)
Description (Translated English) Lead-acid batteries for stationary valve-regulated -- Part 1: Technical requirements
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K84
Classification of International Standard 29.220.20
Word Count Estimation 23,215
Date of Issue 6/24/2014
Date of Implementation 1/22/2015
Older Standard (superseded by this standard) GB/T 19638.2-2005
Quoted Standard GB/T 2408-2008; GB/T 2900.41; GB/T 19638.2-2014; GB/T 23754
Adopted Standard IEC 60896-22-2004, MOD
Regulation (derived from) National Standards Bulletin No. 14 of 2014
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This Standard specifies the fixed type VRLA technical requirements, test methods, inspection rules, marking, packaging, transport and storage. This section applies in the rest of the place, and combined with the use of fixed equipment floating or fixed in

GB/T 19638.1-2014: Lead-acid batteries for stationary valve-regulated -- Part 1: Technical requirements


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Lead-acid batteries for stationary valve-regulated Part 1. Technical requirements ICS 29.220.20 K84 National Standards of People's Republic of China Replacing GB/T 19638.2-2005 Fixed type VRLA Part 1. Technical conditions Part 1. Technicalrequirements (IEC 60896-22.2004, Stationarylead-acidbatteries- Part 22. Valveregulatedtypes-Requirements, MOD) Issued on. 2014-06-24 2015-01-22 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 Symbols 2 5 2 Technical Requirements 5.1 Structural requirements 2 5.2 Safety requirements 3 5.3 Use of claim 3 5.4 durability requirements 4 6 Inspection Method 5 6.1 Measuring Instruments 5 6.2 Test preparation before 6 6.3 appearance, quality inspection 6 Check 6 6.4 Dimensions 6.5 polarity test 6 6.6 tightness test 6 Amount of gas evolved 6.7 Test 6 6.8 resistant to high current capability test 7 6.9 short-circuit current and DC resistance test 7 6.10 Explosion Proficiency Test 8 6.11 Test anti-mist capacity 8 6.12 Test relief valve 9 6.13 resistance capacity test is shorted to ground 10 Flame retardancy test materials 10 6.14 6.15 Proficiency Test against mechanical damage 10 Balancing test terminal voltage of 10 6.16 Capacity performance test 10 6.17 Connectivity between 6.18 single cell test 11 6.19 11 charge retention performance test 6.20 recharge performance test 11 6.21 discharge cycle durability test 12 6.22 40 ℃ float durability test 12 6.23 60 ℃ float durability test 12 6.24 thermal runaway sensitivity test 12 6.25 low temperature sensitivity test 13 Existence and durability test 6.26 Information and warning marks 13 7 Inspection rules 13 8 signs, packaging, transportation and storage 15 8.1 Marking 15 8.2 Packaging 16 8.3 Transport 16 8.4 Storage 16 8.5 Precautions when using 16 Appendix A (informative) on the quality of the battery limit, lower limit 17

Foreword

GB/T 19638 "Fixed type VRLA batteries" is divided into two parts. --- Part 1. Technical conditions; --- Part 2. product varieties and specifications. This section GB/T 19638 Part 1. This section drafted in accordance with GB/T 1.1-2009 given rules. This Part replaces GB/T 19638.2-2005 "stationary VRLA batteries." This portion of the GB/T 19638.2-2005 compared to the main part of the following changes. --- Increase the "ambient temperature" "floating battery (group)" "fully charged" "actual capacity" and the definition (see Chapter 3); --- Modify the battery quality reference value, tied to informative annex; --- Modify the flame resistance of technical requirements and test methods for materials (see 5.2.8,6.14); --- Increased connectivity between single-cell technology requirements and test methods (see 5.3.3,6.18); --- Remove the voltage drop connection technical requirements (see the 2005 version 6.3.3); --- Remove the overcharge resistance capability technical requirements (see 2005 Version 6.3.4); --- Remove the overcharge cycle durability technical requirements (see 2005 Version 6.4.1.2); --- Cycle durability revised technical requirements and test methods (see 5.4.1,6.22,6.23); --- Modify the sensitivity of technical requirements and test methods for thermal runaway (see 5.4.2,6.24); --- Modify the low sensitivity of technical requirements and test methods (see 5.4.3,6.25); --- Modify the amount of gas evolved test methods (see 6.7); --- Modify the capacity performance test methods (see 6.17); --- Modify the charge retention performance test methods (see 6.19). --- Increased YD/T 799-2010 "Communication with VRLA batteries," the "battery terminal voltage balance" requirement And test methods (see 5.3.1,6.16). This section uses redrafted law revision of international standards IEC 60896-22.2004 "Fixed lead-acid batteries - Part 22. Valve Control Type test methods. " This part of IEC 60896-22.2004 compared to the technical differences and the reasons are as follows. --- IEC 60896-22.2004 "Fixed lead-acid batteries - Part 22. valve-regulated type test method" provides for a total of 21 technical Requirements and test methods; This standard uses of which 17 technical requirements and test methods (which equivalent to 12 to modify mining With five), there are four requirements are not adopted. Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents. This part is proposed by the China Electrical Equipment Industrial Association. The lead-acid batteries in part by the National Standardization Technical Committee (SAC/TC69) centralized. This part mainly drafted by. Leoch Battery Co., Ltd. Jiangsu double Deng Group Co., Ltd., Shandong Sacred Sun Power Company Limited Secretary, Shenyang Institute of batteries, Harbin Guangyu Battery Co., Ltd., Zhejiang Wolong Electric Group Beacon Power Co., the Department of Shaoxing With Battery Co., Ltd., Jiangsu Fu new energy storage technologies Co., Ltd., Fujian Province, China Fujian Power Company Limited, Hunan Fengri power Electric Co., Ltd. days to Battery Group, AMD Power Co., Ltd., Jiangsu Su in Battery Technology Development Co., Ltd., Beijing Force Standard Technology Co., Ltd, Changxing County, battery industry associations, national light electric vehicles and battery Product Quality Supervision and Inspection Center, Taizhou City of Quality and Technical Supervision and Testing Institute, Zhejiang green power supply product quality inspection center. Participated in the drafting of this section. Jiang Su Chaowei Power Co., Ltd., Zhejiang Jiang Jujiang Power Manufacturing Co., Ltd., Zhejiang Electric Co., Jester The company, Henan AMD Power Co., Ltd. Zhejiang Changxing Power Co., Ltd. Golden Sun, Huzhou long wide Haotian Power Co., Ltd. Changxing into the public electricity Source Co., Ltd. Anhui eternal power, prestige Jiangxi Power Energy Technology Co., Ltd. The main drafters of this section. Iraq Xiaobo, Dong Jie, Xue Yu, Ruan Li, Xue Kui network, Zhouqing Shen, Xing Kai, Zhu Weimin, Zhu Wenwu, Spring Hill home, I'm the tree, Li Lihua, Fang Ming learn new Yang Xin, Shen Restoration, Liu Ning, Yang Yuanling, Zang Ning. The drafters of some of the participants. the mother Jianping, Wu Zhanguo, Xuren Xian, firewood into mine, open subtlety, holding Shen Di, Qian Shun-wing, Wurong Liang, Xu years. This part of the standard replaces the previous editions. --- GB/T 19638.2-2005. Fixed type VRLA Part 1. Technical conditions

1 Scope

This section GB/T 19638 specifies the fixed-type VRLA battery of technical requirements, test methods, inspection rules, marks, packages Loading, transport and storage. This section applies to and in conjunction with the fixed equipment in stationary places together using float or fixed in the battery compartment to pass Letter, switching equipment, power, emergency power and uninterruptible power supply or a similar use of all fixed-type VRLA batteries (hereinafter referred to as the accumulator Batteries) and batteries. Sulfuric acid electrolyte in the battery is not flowing, or adsorbed on the pore structure between the electrodes or in colloidal form. This section does not apply to start with, and general storage use lead-acid batteries and batteries and so on.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 2408-2008 Plastics - Determination of burning behavior of horizontal and vertical (IEC 60695-11-10.1999, IDT) GB/T 2900.41 Electrotechnical terminology primary cells and batteries (GB/T 2900.41-2008, IEC 60050 (482).2003, IDT) GB/T 19638.2-2014 stationary VRLA batteries - Part 2. Product varieties and specifications GB/T 23754 lead-acid battery slot

3 Terms and Definitions

GB/T 2900.41 define the following terms and definitions apply to this document. 3.1 Ambient temperature ambienttemperature 5mm around the battery or batteries within the medium temperature. 3.2 Floating battery (group) floatingbattery Battery (group) terminal is permanently connected to a constant voltage, which is sufficient to maintain a constant voltage battery (group) remains fully charged State, when the normal power supply is temporarily interrupted, battery (group) can provide electricity. 3.3 Fully charged fulcharge Battery all active substances available have been transformed into full state of charge. 3.4 Actual capacity actualcapacity Under the conditions specified discharge rate, discharge termination voltage and temperature, battery or battery output power, in ampere hours (Ah) represented.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 19638.1-2014_English be delivered?

Answer: Upon your order, we will start to translate GB/T 19638.1-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 19638.1-2014_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 19638.1-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.