US$159.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 19215.4-2017: Cable trunking and ducting systems for electrical installations -- Part 2: Particular requirements -- Section 4: Service poles Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 19215.4-2017 | English | 159 |
Add to Cart
|
3 days [Need to translate]
|
Cable trunking and ducting systems for electrical installations -- Part 2: Particular requirements -- Section 4: Service poles
| Valid |
GB/T 19215.4-2017
|
PDF similar to GB/T 19215.4-2017
Basic data | Standard ID | GB/T 19215.4-2017 (GB/T19215.4-2017) | | Description (Translated English) | Cable trunking and ducting systems for electrical installations -- Part 2: Particular requirements -- Section 4: Service poles | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K65 | | Classification of International Standard | 29.120.10 | | Word Count Estimation | 8,869 | | Date of Issue | 2017-07-31 | | Date of Implementation | 2018-02-01 | | Quoted Standard | GB/T 4208; GB/T 19215.1-2003; ISO 9328-5-1991 | | Adopted Standard | IEC 61084-2-4-1996, MOD | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies that the auxiliary end is intended for containment and, if necessary, for separating conductors, cables or cords and / or other electrical equipment. This auxiliary end, as shown in Figure 101, can be moved or fixed in any direction. This standard does not apply to conduits, cable trays or staircases, as well as current-carrying components in the system. |
GB/T 19215.4-2017: Cable trunking and ducting systems for electrical installations -- Part 2: Particular requirements -- Section 4: Service poles ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Cable trunking and ducting systems for electrical installations.Part 2. Particular requirements.Section 4. Service poles
ICS 29.120.10
K65
National Standards of People's Republic of China
Electrical installation of cable trunking system
Part 2. Special Requirements Section 4. Auxiliary
Part 2.Particularrequirements-Section4.Servicepoles
(IEC 61084-2-4.1996, MOD)
2017-07-31 Posted
2018-02-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
China National Standardization Administration released
Directory
Foreword Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
4 General requirements
5 General description of the test 2
6 Categories 2
7 logo 2
8 size 2
9 structure 2
10 mechanical properties 3
11 flame spread 4
12 Electrical Performance 4
External influences 4
Foreword
"Cable duct system for electrical installation" is divided into the following sections.
--- Part 1. General requirements (GB/T 19215.1);
--- Part 2. Particular requirements Section 1. Cable duct systems for wall or ceiling mounting (GB/T 19215.2);
--- Part 2. Particular requirements Section 2. Cable duct systems installed under the floor and flush with the floor (GB/T 19215.3);
--- Part 2. Special Requirements Section 4. Auxiliary (GB/T 19215.4);
This section is "Section 4 of the cable duct system for electrical installation" Part 2.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section uses the redrafted law to amend the use of IEC 61084-2-4.1996 "Electrical Installation of cable trunking system Part 2. Special
Requirements section 4. Auxiliary end. "
This part of IEC 61084-2-4.1996 technical differences and the reasons are as follows.
--- On the normative references, this section made a technical difference with the adjustment to adapt to China's technical conditions, adjust the situation
Concentration reflected in the second chapter "Normative references", the specific adjustments are as follows.
● Replaced IEC 61084-1 with revision GB/T 19215.1-2003 of international standard;
● Added GB/T 4208.
This section made the following editorial changes.
--- In accordance with the relevant provisions of GB/T 1.1, in the first chapter "range" added "" electrical installation cable trunking system "of this part of regulations
Set the signs, dimensions, structure, mechanical properties, flame spread, electrical properties, external
Ministry of influence and other technical requirements. "
--- Removed Appendix A
This part is proposed by China Electrical Equipment Industry Association.
This part of the National Electrical Accessories Standardization Technical Committee (SAC/TC67) centralized.
This part of the drafting unit. Guangdong South China Institute of Appliances, Zhongshan City, Shun Shing Hardware Products Co., Ltd., Hangzhou Hongyan Electric Co., Ltd.
State Electric Apparatus Research Institute Co., Ltd., Guangdong Yitong Technology Co., Ltd., Weikai Testing Technology Co., Ltd.
The main drafters of this section. Liu Bin, Leonard Kennedy, Zhou Xiaoqing, Cai Jun, Wu Weiguo, a hope high, Li Qin.
Electrical installation of cable trunking system
Part 2. Special Requirements Section 4. Auxiliary
1 Scope
GB/T 19215.1-2003 This chapter read.
This section of the "Cable trunking system for electrical installation" specifies the logo, size, structure,
Mechanical properties, flame spread, electrical properties, external effects and other technical requirements.
Auxiliary ends as specified in this standard are intended to accommodate and, if necessary, to separate conductors, cables or cords and/or other electrical equipment. This auxiliary
As shown in Figure 101, the aids can be moved or fixed in any orientation.
This section does not apply to the catheter, cable tray or ladder, as well as the current-carrying components in the system.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 4208 enclosure protection (IP code) (GB/T 4208-2008, IEC 60529.2001, IDT)
GB/T 19215.1-2003 cable trunking system for electrical installation Part 1. General requirements (IEC 61084-1.1991,
MOD)
ISO 9328-5.1991 Steel plates and strips for pressure purposes - Technical delivery conditions - Part 5. Steelplates
andstripsforpressurepurposes-Technicaldeliveryconditions-Part 5.Austeniticsteels)
3 Terms and definitions
GB/T 19215.1-2003 defined and the following terms and definitions apply to this document.
3.101
Auxiliary servicepole
Equipped with special fixtures provided by the manufacturer, to accommodate or contain the ability to easily connect to low-voltage power systems, telecommunications systems, etc.
Accessories designed pipe system.
3.102
Can be relocated with the installation service auxiliary servicepoleforre-locatablemounting
It is also easy to install in a fixed way but reposition it so it can be connected to a flexible cable or cord and plug
Auxiliary end of the power supply.
3.103
Fixed installation with auxiliary servicepoleforfixedmounting
Auxiliary for fixed installation but not easily removable.
4 General requirements
GB/T 19215.1-2003 This chapter applies.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 19215.4-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 19215.4-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 19215.4-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 19215.4-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|