HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (20 Jul 2025)

GB/T 32517-2024 English PDF

US$959.00 · In stock
Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 32517-2024: Installation couplers intended for permanent connection in fixed installations
Status: Valid

GB/T 32517: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 32517-2024English959 Add to Cart 7 days [Need to translate] Installation couplers intended for permanent connection in fixed installations Valid GB/T 32517-2024
GB/T 32517-2016English779 Add to Cart 6 days [Need to translate] Installation couplers intended for permanent connection in fixed installations Valid GB/T 32517-2016

PDF Samples

Basic data

Standard ID GB/T 32517-2024 (GB/T32517-2024)
Description (Translated English) Installation couplers intended for permanent connection in fixed installations
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K65
Word Count Estimation 48,458
Date of Issue 2024-08-23
Date of Implementation 2024-08-23
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration
GB/T 32517-2024 Image

Similar standards

GB/T 4343.2   GB/T 3883.311   JB/T 10772   GB/T 42324   GB/T 19215.5   

GB/T 32517-2024: Installation couplers intended for permanent connection in fixed installations

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 29.120.99 CCSK65 National Standard of the People's Republic of China Replaces GB/T 32517-2016 Mounting couplers for permanent connections in fixed installations (IEC 61535.2023,MOD) Released on 2024-08-23 2025-03-01 Implementation State Administration for Market Regulation The National Standardization Administration issued

Table of Contents

Preface III 1 Scope 1 2 Normative references 1 3 Terms and Definitions 2 4 General requirements 4 5 Test conditions 4 6 Rating 5 7 Categories 6 8 Logo and Documentation 7 9 Hazardous Compatibility 8 10 Protection against electric shock 9 11 Terminals, ends and connecting wires 10 12 Structure 10 13 Prevent harmful solid foreign matter from entering and harmful water from entering 14 14 Insulation resistance and electrical strength 14 15 Contact structure 15 16 Temperature rise 16 17 Breaking capacity 17 18 Force required to separate the components of the mounted coupler 17 19 Cables and their connections17 20 Mechanical strength 20 21 Heat resistance and anti-aging performance 20 22 Screws, current-carrying parts and their connections 22 23 Creepage distance, electrical clearance and insulation distance through 23 24 Resistance to abnormal heat and tracking 26 25 Rust prevention27 Appendix A (informative) Additional tests and requirements for mounted couplers for ambient temperatures below -5°C and not less than -45°C 28 Appendix B (Informative) User Guide 29 Appendix C (Normative) Number of sample groups used in the test and the test procedure for each group 32 Appendix D (Normative) Conventional ground continuity test 33 Appendix E (Normative) Warning symbols for DC applications 34 Appendix F (Normative) Test circuit for temperature rise test 35 References 39 Figure 1 Cable fixing component test device 19 Figure 2 Device for measuring torsion (example) 19 Figure 3 Ball pressure test device 21 Figure 4 Explanation of “Widget” 26 Figure B.1 Example of using a mounted coupler 30 Figure B.2 Mounted coupler 31 shown in enlarged area of Figure B.1 Figure E.1 Symbol "Do not connect or disconnect under load" 34 Figure F.1 1P N PE mounted coupler, including N 35 Figure F.2 1P N PE mounted coupler, including PE 35 Figure F.3 3P N PE mounted coupler, 3 phases with load 35 Figure F.4 3P N PE mounted coupler, N and PE with load 36 Figure F.5 1P N PE splitter, phase and N with load 36 Figure F.6 1P N PE splitter, phase and PE load 37 Figure F.7 3P N PE- to 1P N PE splitter, 3-phase load 37 Figure F.8 3P N PE- to 1P N PE splitter, N and PE phases carry 38 Table 1 Rated voltage of mounted couplers for AC applications 5 Table 2 Rated voltage of mounted couplers for DC applications 5 Table 3 Classification of mounted couplers 6 Table 4 Test current for mounted couplers 16 Table 5 Forces applied to cable fixing components 18 Table 6 Torques used in tightening and loosening tests 22 Table 7 Mounting coupler for power supply system with maximum voltage to ground of 150VAC and rated pulse voltage of 2.5kV 23 Table 8 Mounting coupler for power supply system with maximum voltage to ground 300VAC and rated pulse voltage 4.0kV 24 Table 9 Single-phase two-wire system 50VDC and single-phase three-wire system 60VDC, rated pulse voltage 0.8kV power supply system Mounting coupler 24 Table 10 Power supply system with single-phase two-wire system 120VDC and single-phase three-wire system 240VDC, rated pulse voltage 2.5kV Mounting coupler 25 Table 11 Power supply system with single-phase two-wire system 220VDC and single-phase three-wire system 440VDC, rated pulse voltage 4.0kV Mounting coupler 25 Table C.1 Number of sample groups 32

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents" Drafting. This document replaces GB/T 32517-2016 "Mounted couplers for permanent connections in fixed installations". Compared with.2016, in addition to structural adjustments and editorial changes, the main technical changes are as follows. --- Changed the scope of application, added the maximum current of DC mounted coupler and mounted coupler, changed the maximum current of mounted coupler Applicable temperature range (see Chapter 1, Chapter 1 of the.2016 edition); --- Changed the definition of mounted coupler (see 3.5, 3.5 of the.2016 edition), changed the term terminal block to splitter (see 3.14, 3.10 of the.2016 edition), changed the definition of routine test (see 3.17, 3.13 of the.2016 edition), changed the definition of accessible Definition of (see 3.19, 3.15 of the.2016 edition), added definition of live parts (see 3.22); --- Changed the general description of the test conditions (see 5.1, 5.1 of the.2016 edition); --- Added the rated current type of the mounted coupler and the rated voltage of the mounted coupler in DC applications (see 6.1); --- Added test requirements for rated values (see 6.4); --- Added the classification of mounted couplers (see Chapter 7); --- Changed the requirements for marking and documentation of mounted couplers (see Chapter 8, Chapter 8 of the.2016 edition); --- Increased the connection capacity values of the terminals of the removable wired female and male connectors (see 11.2); --- Changed the test requirements for protection against harmful water ingress (see 13.3, 13.2 of the.2016 edition); --- Added the current for temperature rise test of mounted coupler (see Chapter 16); --- Changed the temperature requirements for the ball pressure test of other insulating material parts of the mounted coupler (see 21.3, 21.3 of the.2016 edition); --- Increased requirements for creepage distance, electrical clearance and through insulation distance (see Chapter 23); --- Added warning symbol requirements for DC applications (see Appendix E); --- The test circuit for temperature rise test has been changed (see Appendix F, Appendix B of the.2016 edition). This document is modified to adopt IEC 61535.2023 "Mounted couplers for permanent connections in fixed installations". The technical differences between this document and IEC 61535.2023 and their reasons are as follows. --- Added "This document specifies the classification, marking and documents, dimensions, structure and (see Chapter 1) to meet the requirements of GB/T 1.1-2020; --- Added "After this test, the mark should still be clearly visible" (see 8.3) in the marking test to adapt to my country's technical conditions and increase the Operability; --- Replaced IEC 60998-2-3 (see 11.1.2) with the normative reference GB/T 13140.4 to adapt to my country's technical conditions and added Operability; --- The normative reference GB/T 4207 replaces IEC 60112 (see Chapter 24) to adapt to my country's technical conditions and increase operability Sex; --- Replaced IEC 60695-2-11 (see 24.1) with the normative reference GB/T 5169.11 to adapt to my country's technical conditions, and added Operability. The following editorial changes were made to this document. ---Replaced IEC 60417.2006 with the informative reference GB/T 5465.1-2009 to adapt to my country's technical conditions and increase the Operability; ---Replace IEC 60309 (all parts) with the informative reference GB/T 11918 (all parts) to adapt to my country's technical requirements parts, increasing operability; ---Replaced IEC 60320 (all parts) with the informative reference GB/T 17465 (all parts) to adapt to my country's technical requirements parts, increasing operability; ---Replaced IEC 61995 (all parts) with the informative reference GB/T 31463 (all parts) to adapt to my country's technical requirements parts, increasing operability; ---Replace IEC 60364 (all parts) with the informative reference GB/T 16895 (all parts) to adapt to my country's technical requirements parts, increasing operability; --- Adjust the order of the appendices according to the order in which they appear in the main text to adapt to my country's technical conditions and increase operability; --- Deleted the notes in Chapter 4 and 5.1 to adapt to my country's technical conditions and increase operability. Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document was proposed by the China Electrical Equipment Industry Association. This document is under the jurisdiction of the National Technical Committee for Standardization of Electrical Accessories (SAC/TC67). This document was drafted by. China Electric Power Research Institute Co., Ltd., WANGO Electronics (Tianjin) Co., Ltd., Jiangsu Tongling Technology Co., Ltd. Ltd., Zhejiang Zhilun Home Furnishing Technology Co., Ltd., Bull Group Co., Ltd., Hangzhou Hongshi Electric Co., Ltd., Weikai Testing Technology Co., Ltd. Technology Co., Ltd., Zhejiang Fangyuan Electrical Equipment Testing Co., Ltd., Guangdong South China Home Appliance Research Institute, China Quality Certification Center, Shenzhen Linke Electric Co., Ltd., Shenzhen Oushengke Connection Technology Co., Ltd., Guangdong Zhongren South China Testing Technology Co., Ltd., Shandong Yaosi Intelligent Technology Co., Ltd. Company, Dongguan Dianwei Electronics Co., Ltd., Zhejiang Yuehua Telecom Co., Ltd., Yiwu Hongtao Mould Co., Ltd., Hangzhou Fangxing Watch Co., Ltd. company. The main drafters of this document are. Sun Ting, Wang Fang, Wu Weidong, Chen Heng, Cai Jun, Liu Bingren, Shan Weixiao, Li Zhongyao, Lai Jin......