HOME   Cart(10)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB/T 17737.105-2018 English PDF

US$119.00 ยท In stock
Delivery: <= 2 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 17737.105-2018: Coaxial communication cables -- Part 1-105: Electrical test methods -- Test for withstand voltage of cable dielectric
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 17737.105-2018English119 Add to Cart 2 days [Need to translate] Coaxial communication cables -- Part 1-105: Electrical test methods -- Test for withstand voltage of cable dielectric Valid GB/T 17737.105-2018

PDF similar to GB/T 17737.105-2018


Standard similar to GB/T 17737.105-2018

GB/T 17737.102   GB/T 17737.101   GB/T 17737.103   GB/T 17737.119   GB/T 17737.113   GB/T 17737.100   

Basic data

Standard ID GB/T 17737.105-2018 (GB/T17737.105-2018)
Description (Translated English) Coaxial communication cables -- Part 1-105: Electrical test methods -- Test for withstand voltage of cable dielectric
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard L26
Classification of International Standard 33.120.10
Word Count Estimation 6,669
Date of Issue 2018-03-15
Date of Implementation 2018-10-01
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 17737.105-2018: Coaxial communication cables -- Part 1-105: Electrical test methods -- Test for withstand voltage of cable dielectric


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Coaxial communication cables--Part 1-105. Electrical test methods--Test for withstand voltage of cable dielectric ICS 33.120.10 L26 National Standards of People's Republic of China Coaxial communication cable Part 1-105. Electrical test methods Cable dielectric withstand voltage test Coaxialcommunicationcables-Part 1-105.Electricaltestmethods- (IEC 61196-1-105.2005, IDT) Published by.2018-03-15 2018-10-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Administration released

Foreword

GB/T 17737 "Coaxial Communication Cable" has or plans to issue the following parts. --- Part 1. General rules, definitions and requirements; --- Part 1-100. General requirements for electrical test methods; --- Part 1-101 . Electrical test methods Conductor direct current resistance test ; --- Part 1-102 . Electrical test methods ; Insulation resistance test of dielectrics for cables ; --- Part 1-103 . Electrical test methods Capacitance test of cables ; --- Part 1-104 . Electrical test methods ; Capacitance stability test of cables ; --- Part 1-105. Electrical test methods for withstand voltage test of cable dielectrics; --- Part 1-101 . Electrical test methods Voltage withstand test of cable sheathing ; --- Part 1-107 . Electrical test methods Vibrating cable charge level (mechanically induced noise) test; --- Part 1-108. Electrical test methods Characteristic impedance, phase delay, group delay, electrical length and propagation speed test; --- Part 1-110 . Electrical test method continuity ; --- Part 1-111 . Electrical test methods Stability test for phase constants ; --- Part 1-112. Electrical test methods Return Loss (Impedance Consistency) test; --- Part 1-113 . Electrical test method attenuation constant test ; --- Part 1-114 . Electrical test methods Inductors ; --- Part 1-115. Electrical test method impedance uniformity (pulse/step function return loss) test; --- Part 1-116 . Electrical test methods TDR method measuring characteristic impedance ; --- Part 1-119 . Electrical test methods RF power rating ; --- Part 1-122. Electrical test methods - Cross-talk test between coaxial cables; This part is part 1-105 of GB/T 17737. This section was drafted in accordance with the rules given in GB/T 1.1-2009. This section uses the translation method equivalent to the use of IEC 61196-1-105.2005 "coaxial communication cable Part 1-105. Electrical test method Method for testing dielectric strength of cable media." Please note that some of the contents of this document may involve patents. The issuing agency of this document does not assume responsibility for identifying these patents. This section was proposed by the Ministry of Industry and Information Technology of the People's Republic of China. This part is under the jurisdiction of the National Standardization Technical Committee for High Frequency Cables and Connectors for Electronic Equipment (SAC/TC190). This section was drafted by. Tianjin Liuqiu Cable Co., Ltd. The main drafters of this section are. Wei Wei, Li Lianxi, Bi Jianjin, Zhang Guoju, Wu Yulin, Jiang Hui, Yu Jian, Wang Ruixi, Wu Zhengping and Tian Xin. Coaxial communication cable Part 1-105. Electrical test methods Cable dielectric withstand voltage test

1 Scope

This part of GB/T 17737 applies to coaxial communication cables. It specifies the test method for determining dielectric withstand voltage of coaxial cables.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article Pieces. For undated references, the latest version (including all amendments) applies to this document. GB/T 17737.1-2013 Coaxial telecommunication cable Part 1. General specifications General, definitions and requirements (IEC 61196-1.2005, IDT)

3 Terms and definitions

The terms and definitions defined in GB/T 17737.1-2013 apply to this document.

4 dielectric withstand voltage test

4.1 Principle The purpose of this test is to determine the withstand voltage of the dielectric under AC or DC conditions. 4.2 Test Equipment Test equipment includes. --- AC or DC power. ---KVolt meter. The frequency of AC voltage should be 40Hz~60Hz, and the waveform should be sine wave. 4.3 sample preparation The test shall be performed on finished cables that have passed the continuity test. Both ends of the cable should be stripped of conductors of sufficient length to avoid breakdown or failure Discharge. The insulation on the stripped conductors at both ends should be cleaned. 4.4 Procedures The insulation between the inner and outer conductors of the cable or between the conductors shall withstand an ac or dc voltage of 1 min. The voltage value should comply with the relevant sectional specification Or detailed specifications. The voltage boost rate of the test voltage should not exceed 2 kV/s.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 17737.105-2018_English be delivered?

Answer: Upon your order, we will start to translate GB/T 17737.105-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 2 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 17737.105-2018_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 17737.105-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.