US$174.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 17626.24-2012: Electromagnetic compatibility -- Testing and measurement techniques -- Test methods for protective devices for HEMP conducted disturbance Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 17626.24-2012 | English | 174 |
Add to Cart
|
3 days [Need to translate]
|
Electromagnetic compatibility -- Testing and measurement techniques -- Test methods for protective devices for HEMP conducted disturbance
| Valid |
GB/T 17626.24-2012
|
PDF similar to GB/T 17626.24-2012
Basic data | Standard ID | GB/T 17626.24-2012 (GB/T17626.24-2012) | | Description (Translated English) | Electromagnetic compatibility -- Testing and measurement techniques -- Test methods for protective devices for HEMP conducted disturbance | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | L06 | | Classification of International Standard | 33.100 | | Word Count Estimation | 9,989 | | Quoted Standard | GB/T 4365-2003 | | Adopted Standard | IEC 61000-4-24-1997, IDT | | Regulation (derived from) | National Standards Bulletin 2012 No. 28 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the high-altitude electromagnetic pulse (HEMP) protection device conduction disturbance test methods. It includes the breakdown voltage and the voltage limiting characteristic test, and HEMP conditions, the voltage (u) and current |
GB/T 17626.24-2012: Electromagnetic compatibility -- Testing and measurement techniques -- Test methods for protective devices for HEMP conducted disturbance ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Electromagnetic compatibility. Testing and measurement techniques. Test methods for protective devices for HEMP conducted disturbance
ICS 33.100
L06
National Standards of People's Republic of China
Electromagnetic compatibility test and measurement technology
Test methods for protective devices for HEMP conducted harassment
(IEC 61000-4-24.1997, IDT)
Issued on. 2012-11-05
2013-02-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
GB/T 17626 "electromagnetic compatibility test and measurement technology" into the following sections.
GB/T 17626.1-2006 Electromagnetic compatibility - Testing and measurement techniques - Overview of immunity tests
GB/T 17626.2-2006 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test
GB/T 17626.3-2006 Electromagnetic compatibility - Testing and measurement techniques RFEMS test
GB/T 17626.4-2008 Electromagnetic compatibility - Testing and measurement techniques - Electrical fast transient burst immunity test
GB/T 17626.5-2008 Electromagnetic compatibility - Testing and measurement techniques - Surge (impact) immunity test
GB/T 17626.6-2008 Electromagnetic compatibility - Testing and measurement techniques Immunity to conducted disturbances induced field
GB/T 17626.7-2008 Electromagnetic compatibility - Testing and measurement techniques - power supply systems and equipment connected harmonics, interharmonics measurements and
Measuring Instruments Guide
GB/T 17626.8-2006 Electromagnetic compatibility - Testing and measurement techniques - Power frequency magnetic field immunity test
GB/T 17626.9-2011 Electromagnetic compatibility - Testing and measurement techniques - Pulse magnetic field immunity test
GB/T 17626.10-1998 electromagnetic compatibility test and measurement techniques - Damped oscillatory magnetic field immunity test
GB/T 17626.11-2008 Electromagnetic compatibility Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity
test
GB/T 17626.12-1998 electromagnetic compatibility test and measurement techniques - Oscillatory waves immunity test
GB/T 17626.13-2006 electromagnetic compatibility test and measurement technology AC power port harmonics and interharmonics including mains signaling
Low frequency immunity tests
GB/T 17626.14-2005 Electromagnetic compatibility Testing and measurement techniques - Voltage fluctuation immunity test
GB/T 17626.15-2011 electromagnetic compatibility test and measurement technology scintillation Functional and design specifications
GB/T 17626.16-2007 electromagnetic compatibility test and measurement technology 0Hz ~ 150kHz common mode conducted disturbances immunity test
GB/T 17626.17-2005 electromagnetic compatibility test and measurement technology dc input power port immunity test ripple
GB/T 17626.27-2006 Electromagnetic compatibility Testing and measurement techniques - Unbalance, immunity test
GB/T 17626.28-2006 electromagnetic compatibility test and measurement techniques - Variation of power frequency, immunity test
GB/T 17626.29-2006 electromagnetic compatibility test and measurement technology dc input power port voltage dips, short interruptions and
Voltage variations immunity tests
GB/T 17626.30-2012 electromagnetic compatibility test and measurement techniques - Power quality measurement methods
This section GB/T 17626 of Part 24.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section identical with the international standard IEC 61000-4-24.1997 "4-24 unit of electromagnetic compatibility (EMC) Testing and measurement techniques
Points. HEMP test methods for protective devices conduction harassment. "
Electromagnetic Compatibility This part of the National Standardization Technical Committee (SAC/TC246) centralized.
This section is responsible for drafting units. China Electric Power Research Institute.
This part of the unit involved in the drafting. State Grid Electric Power Research Institute.
The main drafters of this section. Wu Hung Wan Baoquan, Zhang Jiangong, Zhang Guangzhou, Li Ni, Zhang Zeping.
Electromagnetic compatibility test and measurement technology
Test methods for protective devices for HEMP conducted harassment
1 Scope
GB/T 17626 provisions of this part of the test method for high-altitude electromagnetic pulse (HEMP) conducted disturbance protection devices. It includes
Breakdown voltage and test voltage limiting characteristics, as well as the conditions under HEMP, voltage (u) and current (i) as a function of time when rapid change
Methods of measurement of residual voltage.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 4365-2003 Electrotechnical terminology Electromagnetic compatibility (IEC 60050 (161).1990, IDT)
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
DUT
Test apparatus.
3.2
Gas discharge tube gasdischargetube
One or several sealing gap of two or three metal electrode, and the gas pressure within the gas mixture can be controlled to protect
Equipment or operator from high transient voltage damage.
3.3
Primary protection element primaryprotectionelement
From the unprotected side protection measures, the first set of shunt most of the surge current protection element.
3.4
Protection side protectedside
Protection measures, the protected side of the device is located.
3.5
Unprotected side unprotectedside
Protection measures, the surge side will appear.
4 Test Method for conducting harassment protection device
4.1 Overview
Under HEMP conditions, protection of actual performance depends largely on the way it is connected to applications, as well as nearby
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 17626.24-2012_English be delivered?Answer: Upon your order, we will start to translate GB/T 17626.24-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 17626.24-2012_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 17626.24-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|