HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (26 Oct 2025)

GB/T 14849.6-2014 English PDF

US$139.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 14849.6-2014: Methods for chemical analysis of silicon metal -- Part 6: Determination of carbon -- Infrared absorption method
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 14849.6-2014English139 Add to Cart 3 days [Need to translate] Methods for chemical analysis of silicon metal -- Part 6: Determination of carbon -- Infrared absorption method Valid GB/T 14849.6-2014

PDF similar to GB/T 14849.6-2014


Standard similar to GB/T 14849.6-2014

GB/T 20975.1   GB/T 14849.5   GB/T 14849.4   GB/T 14849.3   GB/T 14849.1   GB/T 14849.11   

Basic data

Standard ID GB/T 14849.6-2014 (GB/T14849.6-2014)
Description (Translated English) Methods for chemical analysis of silicon metal -- Part 6: Determination of carbon -- Infrared absorption method
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard H12
Classification of International Standard 77.120.10
Word Count Estimation 6,668
Date of Issue 12/5/2014
Date of Implementation 5/1/2015
Quoted Standard GB/T 8170
Regulation (derived from) Announcement of Newly Approved National Standards 2014 No. 27
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This Standard specifies Determination of the carbon content of the silicon industry. This Standard is applicable to the determination of carbon content in Silicon measuring range: 0. 010% to 0. 50%.

GB/T 14849.6-2014: Methods for chemical analysis of silicon metal -- Part 6: Determination of carbon -- Infrared absorption method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of sillicon metal Part 6... Determination of carbon Infrared absorption method ICS 77.120.10 H12 National Standards of People's Republic of China The method of chemical analysis of silicon Part 6. Determination of carbon content by infrared absorption method Part 6. Determinationofcarbon-Infraredabsorptionmethod Issued on. 2014-12-05 2015-05-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

GB/T 14849 "industrial silicon chemical analysis method" is divided into nine sections. --- Part 1. Determination of iron content 1,10 phenanthroline spectrophotometry; --- Part 2. Determination of aluminum content of chromium Azure -S spectrophotometry; --- Part 3. Determination of calcium content by flame atomic absorption spectrometry, spectrophotometry Chlorophonazo Ⅰ; --- Part 4. Determination of impurity elements inductor coupled plasma atomic emission spectrometry; --- Part 5. Determination of impurity elements in the X-ray fluorescence spectrometry; --- Part 6. Determination of carbon content by infrared absorption method; --- Part 7. Determination of phosphorus content - Molybdenum blue spectrophotometric method; --- Part 8. Determination of copper content PADAP spectrophotometry; --- Part 9. Determination of titanium content of methane antipyrine spectrophotometric method. This section GB/T 14849 Part 6. This section drafted in accordance with GB/T 1.1-2009 given rules. The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized. This section is responsible for drafting unit. Kunming Metallurgical Institute New Materials Co., Ltd., Kunming Metallurgy Research Institute, Yunnan Yongchang Silicon Co. Shares the company. Participated in the drafting of this section. Yunnan Entry-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch, Luoyang Sino-silicon High-tech Co., Ltd., Zhejiang Sheng silicon industry. The main drafters of this section. to Zhao, Zhang Yunhui, Zhaode Ping, Ruogu Kang, Zhou Jie, Zhou Yun, Wang Honglei, Xie Qin, Jin Bo, Xiao-Jing Yang, Liuying Bo, Tang Fei, Chen Ketong, Nie Changhong. The method of chemical analysis of silicon Part 6. Determination of carbon content by infrared absorption method

1 Scope

This section GB/T 14849 specifies the method for determination of carbon content in the silicon industry. This section applies to the determination of the carbon content of the silicon industry, measurement range. 0.010% to 0.50%.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 8170 repair value expressed about the rules and limit values \u200b\u200band judgment

3 Method summary

Sample in the high temperature combustion of the high-frequency induction furnace in an oxygen stream, which impurities are converted to carbon dioxide gas, oxygen gas from the carrier to the infrared detector The measuring chamber, detecting the absorption of specific wavelengths of infrared light intensity, the absorption is proportional to the intensity and concentration of carbon dioxide, according to accept the light detector Varying intensity measured carbon content.

4 Reagents and materials

4.1 oxygen purity of not less than 99.995%. 4.2 flux (mass ratio, W. Sn. Fe = 1.5.0.15.0.3), carbon content less than 0.001%, particle size of 0.5mm ~ 1.0mm. 4.3 Standard sample. certified national standards for sample (carbon content of 0.010% to 0.50%). 4.4 Crucible. special ultra-low carbon and sulfur analysis, previously calcined at 1100 ℃ high temperature muffle furnace in 4h, cooled placed in a desiccator. 4.5 crucible tongs.

5 Instruments

5.1 high-frequency infrared carbon and sulfur analyzer. 5.2 Analytical balance, accuracy of 0.0001g. 5.3 muffle furnace, temperature rating of not less than 1200 ℃.

6 Sample

It should be able to 0.149mm sieve.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 14849.6-2014_English be delivered?

Answer: Upon your order, we will start to translate GB/T 14849.6-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 14849.6-2014_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 14849.6-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information